Loading...
HomeMy WebLinkAboutPS-101 - UTILITY TAGSS-1 EXIST. SAN MH RIM = 889.71 INV = 865.61 E 10" INV = 865.61 W 10" INV = 865.61 N 10" S-2 EXIST. 331 LF SAN SWR MAIN, 10" @ 0.30% (ASSUMED) S-3 EXIST. SAN MH RIM = 888.25 INV = 866.60 E 10" (ESTIMATED) INV = 866.60 SE 10" (ESTIMATED) S-4 EXIST. 38 LIN FT SAN SERVICE, 6" (SIZE ASSUMED) (EXIST. 17 LIN FT RISER; 1:1 SLOPE - ASSUMED) (EXIST. 21 LIN FT @ 1.04% - ASSUMED) INVERT @ S-2 = 866.35 (APPROX.) INVERT @ TOP OF RISER = 883.35 (ASSUMED) S-5 SAN SAMPLING MH, 4' DIA. (SEE DETAIL) RIM = 889.10 INV = 884.90 SE 6" PVC INV = 883.57 N 6" PVC (ESTIAMTED. CONTRACTOR TO VERIFY EXIST. PIPE INVERT PRIOR TO ORDERING STRUCTURES. NOTIFY ENGINEER W/ ANY DISCREPANCIES FROM PLAN.) S-6 74 LIN FT SAN SERVICE, 6" PVC SDR 26 @ 1.04% S-7 CLEANOUT (REFER TO DETAIL) RIM = 889.35 INV = +/- 885.67 S-8 22 LIN FT SAN SWR, 6" PVC SDR 26 @ 1.04% INV @ S-6 = 885.65 ST-1 EXIST. 91 LIN FT SS RCP, 12" @ 1.31 ST-2 EXIST. CONTECH VORTSENTRY WQ UNIT RIM = 887.22 INV = 880.42 SE 12" RCP INV = 880.42 NW 12" RCP ST-3 EXIST. 11 LIN FT SS RCP, 12" @ -0.18% ST-4 EXIST. STM MH RIM = 887.30 INV = 880.40 SE 12" RCP INV = 880.40 SW 12" RCP INV = 880.50 NW 12" RCP ST-5 EXIST. 126 LIN FT SS RCP, 12" @ 1.67% ST-6 EXIST. STM MH RIM = 888.26 INV = 882.60 SE 12" RCP INV = 882.60 SW 12" RCP INV = 882.60 NW 12" RCP INV = 884.96 NE 6" PVC (PIPE TO BE REMOVED & INVERT MORTARED SHUT) ST-7 EXIST. 92 LIN FT SS RCP, 12" @ 1.72% ST-8 EXIST. STM INLET RIM = 887.23 INV = 884.18 SE 12" RCP INV = 884.63 E 6" PVC ST-9 EXIST. 30 LIN FT SS RCP, 12" @ 3.63% ST-10 EXIST. STM INLET RIM = 886.89 INV = 883.69 NE 12" RCP ST-11 EXIST. 16 LIN FT SS RCP, 12" @ 15.50% ST-12 EXIST. STM INLET RIM = 885.93 INV = 882.88 NE 12" RCP ST-13 EXIST. 30 LIN FT SS RCP, 12" @ 2.03% ST-14 EXIST. STM INLET RIM = 887.90 INV = 883.90 NE 12" RCP INV = 883.90 NW 15" RCP ST-15 EXIST. 16 LIN FT SS RCP, 15" @ 1.66% ST-16 EXIST. CONTECH VORTSENTRY WQ UNIT RIM = 888.15 INV = 884.17 SE 15" RCP INV = 884.17 NW 15" RCP ST-17 EXIST. 16 LIN FT SS RCP, 15" @ 1.66% ST-18 EXIST. STM CB (OPEN LID F&G TO REMAIN) RIM = 887.53 PROP. RIM = 887.40 INV = 884.33 SE 15" RCP INV = 884.43 NW 12" RCP (EXIST. PIPE TO BE REPLACED.) INV = 885.00 NW 6" PVC (TO BE CORED. CONTRACTOR TO VERFIY CONDITION OF EXIST. STRUCTURE. REPLACE IF NECESSARY.) ST-19 118 LIN FT SS RCP, 12" @ 0.69% ST-20 STM SWR CB 4' DIA., R-3235 TY A GRATE T/C = 888.96 INV = 885.25 SE 12" RCP INV = 885.25 NW 12" RCP ST-21 56 LIN FT SS RCP, 12" @ 0.45% ST-22 STM SWR CB 4' DIA., R-3235 TY A GRATE T/C = 888.96 INV = 885.50 SE 12" RCP INV = 885.50 S 8" PVC ST-23 39 LIN FT SS PVC ROOF DRAIN, 8" SDR 26 @ 1.00% INV @ BLDG = 885.89 ST-24 95 LIN FT SS PVC ROOF DRAIN, 8" SDR 26 @ 1.00% INV @ ST-23 = 885.65 ST-25 CLEANOUT (SEE DETAIL) RIM = 889.45 INV = 886.60 ST-26 24 LIN FT SS PVC ROOF DRAIN, 8" SDR 26 @ 1.00% INV @ ST-24 = 885.90 INV @ BLDG = 886.14 ST-27 24 LIN FT SS PVC ROOF DRAIN, 8" SDR 26 @ 1.00% INV @ ST-24 = 886.49 INV @ BLDG = 886.73 ST-28 6 LIN FT SS PVC CANOPY DRAIN, 6" SDR 26 @ 1.00% INV @ ST-24 = 885.85 INV @ CANOPY DOWNSPOUT = 885.91 ST-29 6 LIN FT SS PVC CANOPY DRAIN, 6" SDR 26 @ 1.00% INV @ ST-24 = 886.14 INV @ CANOPY DOWNSPOUT = 886.20 ST-30 6 LIN FT SS PVC CANOPY DRAIN, 6" SDR 26 @ 1.00% INV @ ST-24 = 886.34 INV @ CANOPY DOWNSPOUT = 886.40 ST-31 7 LIN FT SS PVC CANOPY DRAIN, 6" SDR 26 @ 1.00% INV @ ST-24 = 886.58 INV @ CANOPY DOWNSPOUT = 886.65 ST-32 67 LIN FT SS PVC CANOPY DRAIN, 6" SDR 26 @ 1.00% INV @ N CANOPY DOWNSPOUT = 885.67 ST-33 3 LIN FT SS PVC CANOPY DRAIN, 6" SDR 26 @ 1.00% INV @ ST-32 = 885.25 INV @ S CANOPY DOWNSPOUT = 885.28 S-9 CLEANOUT (REFER TO DETAIL) RIM = 889.55 INV = 885.88 S-10 31 LIN FT SAN SWR, 4" PVC SDR 26 @ 2.08% INV @ S-8 = 885.90 INV @ BLDG = 886.55 S-11 TWO-WAY CLEANOUT (SEE DETAIL) RIM = 890.25 INV = +/- 886.50 S-12 9 LIN FT SAN SWR, 4" PVC SDR 26 @ 2.08% INV @ S-8 = 885.75 S-13 TWO-WAY CLEANOUT (SEE DETAIL) RIM = 889.50 INV = +/- 885.95 S-14 GREASE TRAP (1,000 GAL.) SEE BUILDING PLUMBING PLAN FOR DETAILS RIM(S) = 890.15 W, 890.10 E INV = 886.30 (INLET) INV = 886.00 (OUTLET) S-15 12 LIN FT SAN SWR, 4" PVC SDR 26 @ 2.08% INV @ BLDG = 886.55 S-16 TWO-WAY CLEANOUT (SEE DETAIL) RIM = 890.25 INV = +/- 886.50 Information contained on this drawing and in all digital files produced for above named project may not be reproduced in any manner without express written or verbal consent from authorized project representatives. ENGINEER'S PROJECT # PRINTED FOR DATE SHEET SHEET NUMBER DRAWN BY: Chick-fil-A 5200 Buffington Road Atlanta, Georgia 30349-2998 REVISION SCHEDULE FSR#CHICK-FIL-A210531 PRELIMINARY 07/21/2022WEST CARMEL (IN) FSUPRELIMINARY04978 NO.DATE DESCRIPTION CHECKED BY: MRJ JFV 9965 N. MICHIGAN ROADCARMEL, IN 46032PS-101P R E L I M I N A R Y NOT FOR CONSTRUCTION UTILITY TAGS