HomeMy WebLinkAboutP-101B-FIRST FLOOR PLUMBING PLAN -AREA BDN MMP-400 1 8" ST 1 P-500 3 4 1 2 3 (13,176 SQ.FT.) 8" ST (8,904 SQ.FT.) C.O. 8" ST 4 2 6 4" V 3" CW 7 8 4"FCO 4"FD-2 4"FD-2 4"FD-2 4"FCO 1 2 3 4 5 6 7 8 D E F G H I 7.8 D.8 D.3 3.2 8" ST 8"ST FCO MAINTENANCE 32 STUDENT 112 MAINTENANCE LARGE EQUIPMENT TRAINING 111 100 PERSON AUDITORIUM 106 MAINTENANCE 30 STUDENT 113 ACCESS CORRIDOR 115 DELIVERY 116 TRASH 117 WATER SERVICE 117A FLAT FLOOR CABIN TRAINER 118 LOUNGE 114 COMMUNITY CENTER LAB 107A LOCKED CABIN TRAINER STG 107B SOUTH CORRIDOR 104 ENTRY STAIR 101 WOMEN 222 MEN 401 ADA 398 UNISEX 389 COMPUTER ROOM 125 COMPUTER ROOM 124 COMPUTER ROOM B 122 COMPUTER ROOM A 121 PARTS STORAGE 120 STAIRS-02 S-002 FUTURE COMPUTER ROOM 127 ENTRY STAIR 101 CABIN TRAINER SUPPORT SPACES 102 RAMP 105 NORTH CORRIDOR 110 GENERAL NOTES: 1. PROVIDE NEW DOMESTIC WATER, SANITARY WASTE, STORM DRAINAGE AND NATURAL GAS SYSTEMS FOR THIS BUILDING. PROVIDE ALL NECESSARY COMPONENTS FOR FULLY OPERATIONAL SYSTEM. INSTALL SYSTEMS IN ACCORDANCE WITH STATE REQUIREMENTS AND LOCAL AUTHORITY HAVING JURISDICTION. COORDINATE THE LOCATION OF ALL UTILITY CONNECTION POINTS, FLOOR DRAINS AND HUB DRAINS FOR EQUIPMENT WITH OTHER TRADES. 2. ALL FLOOR PENETRATIONS TO BE SEALED WATER TIGHT AND COMPLETELY PACKED WITH FIRE STOP MATERIAL BY TRADE CONTRACTORS. 3. ALL PENETRATIONS THROUGH FIRE RESISTANCE RATED CONSTRUCTION SHALL BE PROVIDED A UL LISTED THROUGH PENETRATION FIRESTOP ASSEMBLY. THE RATINGS OF ALL FIRESTOP ASSEMBLIES SHALL BE GREATER THAN OR EQUAL TO THE RATING OF THE PENETRATED BARRIER. 4. CORE DRILL PENETRATIONS IN CONCRETE FLOORS OR WALLS 1-2 INCHES LARGER THAN THE PIPE DRIAMETER OF THE PENETRATING PIPE. 5. NO STURCTURAL MEMBERS SHALL BE CUT, DRILLED OR BURNED WITHOUT THE KNOWLEDGE AND WRITTEN APPROVAL OF OWNER. 6. CONTRACTOR SHALL PROVIDE LABELS (WITH FLOW ARROWS) FOR ALL PIPING. 7. MAINTAIN MAIXIMUM HEADROOM AT ALL LOCATIONS. ALL PIPING TO BE AS TIGHT TO THE UNDERSIDE OF DECK AS POSSIBLE. ALL EXPOSED PIPING SHALL BE APPROVED BY ARCHITECT AND SHALL MAINTAIN REQUIRED CLEARANCES. 8. STORM AND SANITARY PIPING ARE TO BE INSTALLED SLOPED AT CODE ALLOWABLE SLOPES. SHEET TITLE SHEET NUMBER Republic Airways, Inc. 8909 Purdue Road, Suite 300 Indianapolis, IN 46268 317-484-6000 Owner RATIO 101 South Pennsylvania Street Indianapolis, Indiana 46204 317-633-4040 Architect McComas/O'donnell & Naccarato Structural Engineer Mechanical / Electrical Engineer 1717 E. 116th Street, Suite 200 Carmel, IN 46032 317-580-0402 Deem 6831 E. 32nd Street Indianapolis, IN 46226 317-860-2990 PROJECT NO. SHEET ISSUE NOT FOR CONSTRUCTION SEAL | DATE COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE, DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.10/8/2021 10:36:18 AMP-101B FIRST FLOOR PLUMBING PLAN - AREA B 1/8" = 1'-0"P-101B 1 FIRST FLOOR PLUMBING PLAN B # PLAN NOTES 1 8" STORM FROM ABOVE 2 8" STORM DOWN TO BELOW SLAB 3 SEE ENLARGED PLAN FOR WORK IN THIS AREA (P-400) 4 6" STORM FROM ABOVE, TRANSITION TO 8" STORM AT THE ELBOW 6 4" VENT UP FROM BELOW SLAB 7 3" DOMESTIC COLD WATER SERVICE UP FROM BELOW SLAB 8 1" IRRIGATION UP FROM BELOW SLAB 10/19/22