HomeMy WebLinkAboutP-101B-FIRST FLOOR PLUMBING PLAN -AREA BDN MMP-400
1
8" ST
1
P-500
3
4
1
2
3
(13,176 SQ.FT.)
8" ST
(8,904 SQ.FT.)
C.O.
8" ST
4
2
6
4" V
3" CW
7
8
4"FCO
4"FD-2 4"FD-2 4"FD-2
4"FCO
1 2 3 4 5 6 7 8
D
E
F
G
H
I
7.8
D.8
D.3
3.2
8" ST
8"ST FCO
MAINTENANCE 32 STUDENT
112
MAINTENANCE LARGE EQUIPMENT
TRAINING
111
100 PERSON AUDITORIUM
106
MAINTENANCE 30 STUDENT
113
ACCESS CORRIDOR
115
DELIVERY
116
TRASH
117
WATER SERVICE
117A
FLAT FLOOR CABIN TRAINER
118
LOUNGE
114
COMMUNITY CENTER LAB
107A
LOCKED CABIN TRAINER STG
107B
SOUTH CORRIDOR
104
ENTRY STAIR
101
WOMEN
222
MEN
401
ADA
398
UNISEX
389
COMPUTER ROOM
125
COMPUTER ROOM
124
COMPUTER ROOM B
122
COMPUTER ROOM A
121
PARTS STORAGE
120
STAIRS-02
S-002
FUTURE COMPUTER ROOM
127
ENTRY STAIR
101
CABIN TRAINER SUPPORT SPACES
102
RAMP
105
NORTH CORRIDOR
110
GENERAL NOTES:
1. PROVIDE NEW DOMESTIC WATER, SANITARY WASTE, STORM
DRAINAGE AND NATURAL GAS SYSTEMS FOR THIS BUILDING. PROVIDE
ALL NECESSARY COMPONENTS FOR FULLY OPERATIONAL SYSTEM.
INSTALL SYSTEMS IN ACCORDANCE WITH STATE REQUIREMENTS AND
LOCAL AUTHORITY HAVING JURISDICTION. COORDINATE THE
LOCATION OF ALL UTILITY CONNECTION POINTS, FLOOR DRAINS AND
HUB DRAINS FOR EQUIPMENT WITH OTHER TRADES.
2. ALL FLOOR PENETRATIONS TO BE SEALED WATER TIGHT AND
COMPLETELY PACKED WITH FIRE STOP MATERIAL BY TRADE
CONTRACTORS.
3. ALL PENETRATIONS THROUGH FIRE RESISTANCE RATED
CONSTRUCTION SHALL BE PROVIDED A UL LISTED THROUGH
PENETRATION FIRESTOP ASSEMBLY. THE RATINGS OF ALL FIRESTOP
ASSEMBLIES SHALL BE GREATER THAN OR EQUAL TO THE RATING OF
THE PENETRATED BARRIER.
4. CORE DRILL PENETRATIONS IN CONCRETE FLOORS OR WALLS 1-2
INCHES LARGER THAN THE PIPE DRIAMETER OF THE PENETRATING
PIPE.
5. NO STURCTURAL MEMBERS SHALL BE CUT, DRILLED OR BURNED
WITHOUT THE KNOWLEDGE AND WRITTEN APPROVAL OF OWNER.
6. CONTRACTOR SHALL PROVIDE LABELS (WITH FLOW ARROWS) FOR ALL
PIPING.
7. MAINTAIN MAIXIMUM HEADROOM AT ALL LOCATIONS. ALL PIPING TO
BE AS TIGHT TO THE UNDERSIDE OF DECK AS POSSIBLE. ALL
EXPOSED PIPING SHALL BE APPROVED BY ARCHITECT AND SHALL
MAINTAIN REQUIRED CLEARANCES.
8. STORM AND SANITARY PIPING ARE TO BE INSTALLED SLOPED AT CODE
ALLOWABLE SLOPES.
SHEET TITLE
SHEET NUMBER
Republic Airways, Inc.
8909 Purdue Road, Suite 300
Indianapolis, IN 46268
317-484-6000
Owner
RATIO
101 South Pennsylvania Street
Indianapolis, Indiana 46204
317-633-4040
Architect
McComas/O'donnell & Naccarato
Structural Engineer
Mechanical / Electrical Engineer
1717 E. 116th Street, Suite 200
Carmel, IN 46032
317-580-0402
Deem
6831 E. 32nd Street
Indianapolis, IN 46226
317-860-2990
PROJECT NO.
SHEET ISSUE
NOT FOR CONSTRUCTION
SEAL | DATE
COPYRIGHT NOTICE: THIS ARCHITECTURAL
AND ENGINEERING DRAWING IS GIVEN IN
CONFIDENCE AND SHALL BE USED ONLY
PURSUANT TO THE AGREEMENT WITH RATIO.
NO OTHER USE, DISSEMINATION OR
DUPLICATION MAY BE MADE WITHOUT PRIOR
WRITTEN CONSENT OF RATIO. ALL COMMON
LAW RIGHTS OF COPYRIGHT AND OTHERWISE
ARE HEREBY SPECIFICALLY RESERVED.10/8/2021 10:36:18 AMP-101B
FIRST FLOOR
PLUMBING PLAN -
AREA B
1/8" = 1'-0"P-101B
1 FIRST FLOOR PLUMBING PLAN B
# PLAN NOTES
1 8" STORM FROM ABOVE
2 8" STORM DOWN TO BELOW SLAB
3 SEE ENLARGED PLAN FOR WORK IN THIS AREA (P-400)
4 6" STORM FROM ABOVE, TRANSITION TO 8" STORM AT THE ELBOW
6 4" VENT UP FROM BELOW SLAB
7 3" DOMESTIC COLD WATER SERVICE UP FROM BELOW SLAB
8 1" IRRIGATION UP FROM BELOW SLAB
10/19/22