Loading...
HomeMy WebLinkAboutP-103A-THIRD FLOOR PLUMBING PLAN -AREA A5,913 S.F. 5,913 S.F. 5,913 S.F. 3,362 SQ.FT. 1 1 1 6"RD-1 6"ORD-1 6"RD-1 6"ORD-1 1 2 3 4 5 6 7 8 A B C D 7.73.2 C.7 C.6 A.3 A.4 1.8 2.2 2.3 2.4 3.8 4.13.9 5.4 5.5 5.6 6.4 6.5 6.6 7.4 7.5 7.6 7.8 C.8 5.2 6.2 OPEN OFFICE -78 DESKS 304 CONF 303 FTD 305 DEBRIEF 305AIN-FLIGHT NEW HIRE 30 STUDENTS 313 IN-FLIGHT NEW HIRE 30 STUDENTS 310 IN-FLIGHT NEW HIRE 24 STUDENT 311 IN-FLIGHT NEW HIRE 30 STUDENT 312 OPEN OFFICE -78 DESKS 304 WORK AREA 309 WEST CORRIDOR 319 WEST CORRIDOR 319 FTD 306 BRIEF 306B DEBRIEF 307A BRIEF 307B FTD 307 EAST CORRIDOR 302 BRIEF 305B DEBRIEF 306A 4"RD-1 4"ORD-1 4"RD-1 4"ORD-1 15,791 SQ.FT. 10,077 SQ.FT. 3,200 SQ.FT. GENERAL NOTES: 1. PROVIDE NEW DOMESTIC WATER, SANITARY WASTE, STORM DRAINAGE AND NATURAL GAS SYSTEMS FOR THIS BUILDING. PROVIDE ALL NECESSARY COMPONENTS FOR FULLY OPERATIONAL SYSTEM. INSTALL SYSTEMS IN ACCORDANCE WITH STATE REQUIREMENTS AND LOCAL AUTHORITY HAVING JURISDICTION. COORDINATE THE LOCATION OF ALL UTILITY CONNECTION POINTS, FLOOR DRAINS AND HUB DRAINS FOR EQUIPMENT WITH OTHER TRADES. 2. ALL FLOOR PENETRATIONS TO BE SEALED WATER TIGHT AND COMPLETELY PACKED WITH FIRE STOP MATERIAL BY TRADE CONTRACTORS. 3. ALL PENETRATIONS THROUGH FIRE RESISTANCE RATED CONSTRUCTION SHALL BE PROVIDED A UL LISTED THROUGH PENETRATION FIRESTOP ASSEMBLY. THE RATINGS OF ALL FIRESTOP ASSEMBLIES SHALL BE GREATER THAN OR EQUAL TO THE RATING OF THE PENETRATED BARRIER. 4. CORE DRILL PENETRATIONS IN CONCRETE FLOORS OR WALLS 1-2 INCHES LARGER THAN THE PIPE DRIAMETER OF THE PENETRATING PIPE. 5. NO STURCTURAL MEMBERS SHALL BE CUT, DRILLED OR BURNED WITHOUT THE KNOWLEDGE AND WRITTEN APPROVAL OF OWNER. 6. CONTRACTOR SHALL PROVIDE LABELS (WITH FLOW ARROWS) FOR ALL PIPING. 7. MAINTAIN MAIXIMUM HEADROOM AT ALL LOCATIONS. ALL PIPING TO BE AS TIGHT TO THE UNDERSIDE OF DECK AS POSSIBLE. ALL EXPOSED PIPING SHALL BE APPROVED BY ARCHITECT AND SHALL MAINTAIN REQUIRED CLEARANCES. 8. STORM AND SANITARY PIPING ARE TO BE INSTALLED SLOPED AT CODE ALLOWABLE SLOPES. SHEET TITLE SHEET NUMBER Kite Realty Group 30 S. Meridian Street, #1100 Indianapolis, Indiana 46204 Owner Republic Airways Holdings RATIO 101 South Pennsylvania Street Indianapolis, Indiana 46204 317-633-4040 Architect McComas/O'donnell & Naccarato Structural Engineer Mechanical / Plumbing Design/Builder Civil Engineer 8909 Purdue Road, Suite 300 Indianapolis, Indiana 46268 1717 E. 116th Street, Suite 200 Carmel, Indiana 46032 317-580-0402 DEEM LLC 6831 E 32nd Street Indianapolis, Indiana 46226 Kimley Horn 250 East 96th Street, Suite 580 Indianapolis, Indiana 46240 KEY PLAN B A HOTEL PROJECT NO. SHEET ISSUE NOT FOR CONSTRUCTION SEAL | DATE COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE, DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED. TRAINING CENTER Electrical Design/Builder Barth Electric Co., Inc. 1934 N. Illinois Street Indianapolis, Indiana 46202 10/15/2021 11:57:42 AMP-103A THIRD FLOOR PLUMBING PLAN - AREA A Republic Airways Training Center 12195 N. Meridian St. Carmel, Indiana 46032 1/8" = 1'-0" P-103A 1 THIRD FLOOR PLUMBING PLAN A # PLAN NOTES 1 DOWNSPOUT FROM HIGH ROOF BY OTHERS 10/19/22