HomeMy WebLinkAboutP-400-ENLARGED PLUMBING PLAN1 2 3 4 42 1 7 8 E 7.7 D.8 2" SAN 4" V 4" V 2"FD-1 WC-1WC-1 WC-1 WC-1 WC-1H WC-1H WC-1HWC-1H U-1U-1 U-1H 2"FD-1 L-1 L-1L-1H L-1H L-1 L-1 1" HW 1/2" HW 1" HW 1" HW 1" HW 1 1/2" CW2" V 3" CW 2" CW 3" CW 1" HW 1" HWR MSB-1 S-1 WC-1 L-1 L-1H WC-1H FCO 1" HW 2" CW 6 2" SAN 1/2" HW 7 7 7 2" V 4" V 4" V 1" HWR 1 2 1/2" CW 2" V 1/2" CW 2" CW 1" HW 3" CW 1" HW 8 8 8 9 10 11 12 11 4" V 4" V 13 2" V 1" CW BF-1 14 15 16 1 1 3 4 4 1 5 7 8 E 7.7 D.8 6 WC-1H WC-1HWC-1H WC-1H U-1U-1U-1H 2" SAN WC-1 WC-1 WC-1 WC-1 2" SAN 2"FD-1 2"FD-1 L-1L-1 L-1H L-1H L-1 L-1 2" V 4" V 1" HW 2" CW 4" V 2" CW 2" CW 1 1/2" CW 2" V 1" HW 2" CW 1" HWR 1" HW 88 S-1 BF-1 1" HW 1/2" HW 7 7 7 13 17 18 4" ST 4" ST 4" ST 9 10 11 12 14 15 16 WC-1 L-1 L-1HWC-1H 11 1 7 E D.8 1 1/2" CW1" HW 1" HW 2" VWC-1H L-1H BF-1 L-1H L-1 U-1H U-1 WC-1H 2"FD-1 2"FD-1 WC-1HWC-1 WC-1 WC-1 L-1H L-1 L-1 S-1 WC-1 L-1 2" V 2" CW 2" CW 1" HW 3" V 2" V 1/2" CW 1" HW MSB-1 GENERAL NOTES: 1. PROVIDE NEW DOMESTIC WATER, SANITARY WASTE, STORM DRAINAGE AND NATURAL GAS SYSTEMS FOR THIS BUILDING. PROVIDE ALL NECESSARY COMPONENTS FOR FULLY OPERATIONAL SYSTEM. INSTALL SYSTEMS IN ACCORDANCE WITH STATE REQUIREMENTS AND LOCAL AUTHORITY HAVING JURISDICTION. COORDINATE THE LOCATION OF ALL UTILITY CONNECTION POINTS, FLOOR DRAINS AND HUB DRAINS FOR EQUIPMENT WITH OTHER TRADES. 2. ALL FLOOR PENETRATIONS TO BE SEALED WATER TIGHT AND COMPLETELY PACKED WITH FIRE STOP MATERIAL BY TRADE CONTRACTORS. 3. ALL PENETRATIONS THROUGH FIRE RESISTANCE RATED CONSTRUCTION SHALL BE PROVIDED A UL LISTED THROUGH PENETRATION FIRESTOP ASSEMBLY. THE RATINGS OF ALL FIRESTOP ASSEMBLIES SHALL BE GREATER THAN OR EQUAL TO THE RATING OF THE PENETRATED BARRIER. 4. CORE DRILL PENETRATIONS IN CONCRETE FLOORS OR WALLS 1-2 INCHES LARGER THAN THE PIPE DRIAMETER OF THE PENETRATING PIPE. 5. NO STURCTURAL MEMBERS SHALL BE CUT, DRILLED OR BURNED WITHOUT THE KNOWLEDGE AND WRITTEN APPROVAL OF OWNER. 6. CONTRACTOR SHALL PROVIDE LABELS (WITH FLOW ARROWS) FOR ALL PIPING. 7. MAINTAIN MAIXIMUM HEADROOM AT ALL LOCATIONS. ALL PIPING TO BE AS TIGHT TO THE UNDERSIDE OF DECK AS POSSIBLE. ALL EXPOSED PIPING SHALL BE APPROVED BY ARCHITECT AND SHALL MAINTAIN REQUIRED CLEARANCES. 8. STORM AND SANITARY PIPING ARE TO BE INSTALLED SLOPED AT CODE ALLOWABLE SLOPES. SHEET TITLE SHEET NUMBER Kite Realty Group 30 S. Meridian Street, #1100 Indianapolis, Indiana 46204 Owner Republic Airways Holdings RATIO 101 South Pennsylvania Street Indianapolis, Indiana 46204 317-633-4040 Architect McComas/O'donnell & Naccarato Structural Engineer Mechanical / Plumbing Design/Builder Civil Engineer 8909 Purdue Road, Suite 300 Indianapolis, Indiana 46268 1717 E. 116th Street, Suite 200 Carmel, Indiana 46032 317-580-0402 DEEM LLC 6831 E 32nd Street Indianapolis, Indiana 46226 Kimley Horn 250 East 96th Street, Suite 580 Indianapolis, Indiana 46240 KEY PLAN B A HOTEL PROJECT NO. SHEET ISSUE NOT FOR CONSTRUCTION SEAL | DATE COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE, DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED. TRAINING CENTER Electrical Design/Builder Barth Electric Co., Inc. 1934 N. Illinois Street Indianapolis, Indiana 46202 10/15/2021 11:57:48 AMP-400 ENLARGED PLUMBING PLAN Republic Airways Training Center 12195 N. Meridian St. Carmel, Indiana 46032 1/4" = 1'-0" P-400 1 ENLARGED FIRST FLOOR RESTROOM PLAN 1/4" = 1'-0"P-400 2 ENLARGED SECOND FLOOR RESTROOM PLAN 1/4" = 1'-0"P-400 3 ENLARGED THIRD FLOOR RESTROOM PLAN # PLAN NOTES 1 4" SANITARY STACK UP. 2 4" SANITARY STACK DOWN THROUGH SLAB. 3 4" VENT UP TO SECOND LEVEL. 4 2" SANITARY UP TO FLOOR DRAIN. 5 4" SANITARY STACK DOWN IN CHASE. 6 2" COLD WATER DOWN IN CHASE. ROUTE 2" HEADER THROUGH CHASE AND CONNECT 1" COLD WATER TO EACH OF (8) WATER CLOSETS, 3/4" COLD WATER TO EACH OF (3) URINALS AND 1/2" COLD WATER TO EACH OF (3) LAVATORIES. 7 1/2" HOT WATER DOWN IN WALL TO LAVATORY, 1/2" COLD WATER FROM CHASE. 2" SANITARY DOWN AND 2" VENT UP. 8 1/2" HOT AND COLD WATER DOWN IN WALL TO LAVATORY. 2" SANITARY DOWN, 2" VENT UP. 9 1/2" HOT AND COLD WATER DOWN IN WALL TO SINK. 2" SANITARY DOWN, 2" VENT UP. 10 1/2" HOT AND COLD WATER FROM CHASE TO MOP SINK. 3" SANITARY, 2" VENT UP. 11 1-1/2" COLD WATER AND 1/2" HOT WATER DOWN IN CHASE. CONNECT 1/2" HOT AND COLD WATER TO LAVATORY AND CONNECT 1" COLD WATER TO WATER CLOSET. 4" SANITARY THROUGH CHASE TO STACK, 2" VENT THROUGH CHASE TO ABOVE CEILING. 12 1/2" HOT WATER DOWN IN CHASE. 13 4" STORM CONDUCTOR IN CHASE. 14 3" COLD WATER RISER IN CHASE. 1" HOT WATER RISER AND 1" HOT WATER RETURN RISER IN CHASE. 15 1/2" COLD WATER DOWN IN WALL TO BOTTLE FILLER. 2" SANITARY TO STACK, VENTED FROM TOP OF STACK. 16 2" COMBINATION SANITARY/ VENT STACK. 17 4" STORM UP TO ROOF DRAIN. 18 4" STORM UP TO OVERFLOW ROOF DRAIN. 10/19/22