HomeMy WebLinkAboutS-103B-THIRD FLOOR & LOW ROOF FRAMING PLAN -AREA B1 2 3 4 5 6 7 8
D
E
F
G
H
I
7.7
D.8
D.3
MATCHLINE S-103A
9'-9" 29'-2" 6'-1" 14'-9" 18'-8" 39'-6" 39'-6" 28'-9 7/8" 10'-3 1/8"6'-5 3/8" 14'-11 1/4" 7'-9 3/4" 30'-0" 30'-0" 19'-10" 10'-2"196'-6"
3.2
DB
DBSTAIR
PRECAST
STRUCTURE
(BY OTHERS)
PU1 PU1 PU1 PU1
PU1 PU1PU1
PU1
PU1
3" CONC. TOPPING
w/ 6x6-W1.4xW1.4 WWF
FIN. FLR. EL. +134'-0"
5
S-402
6
S-402
7
S-402
4" CONCRETE SLAB
w/ 6x6-W1.4xW1.4 WWF ON
GEOFOAM ON 3" TOPPING
FIN. FLR. EL. +134'-7 1/2"
EXTERIOR
TERRACE
PERGOLA COLUMNS
(SEE ARCH.)
PERGOLA COLUMNS
(SEE ARCH.)
CONC CURB - TYP
9"9"9"2 3/8"HSS10x6x5/8 HSS10x6x5/8PU3
PU3
PU3SEE ARCH. FOR WINDOW SIZE & LOCATION8
S-402
2.6
NOTES:
1) TOP OF PRECAST TOPPING ELEVATION 134'-0", SEE PLAN.
2) INDICATES 3", 22 GA. TYPE 'N' METAL ROOF DECK.
3) INDICATES VERTICAL DIAGONAL BRACING, SEE S-501 FOR ADDITIONAL
INFORMATION.
4) ALL BEAM/GIRDER CONNECTIONS SHALL BE DESIGNED FOR A MINIMUM
UNFACTORED VERTICAL REACTION OF 15 kips, UNLESS NOTED GREATER.
CONNECTIONS TO COLUMNS TO BE PER GENERAL NOTES. ALL REACTIONS SHOWN ON
PLAN ARE SERVICE LOADS.
5) ADDITIONAL REINFORCING IN TOPPING TO BE PROVIDED BY PRECAST
MANUFACTURER.
D1
DB
SS
ROC
PROFE.AI GNNIOLAE RER
SASTATE OF
860325
NNID
No.
A ENI
R
M
IED
EG
N
TSE
Y MOC
DE
c
SHEET TITLE
SHEET NUMBER
RATIO
101 South Pennsylvania Street
Indianapolis, Indiana 46204
317-633-4040
Architect
McComas/O'Donnell & Naccarato
Structural Engineer
Civil Engineer
Mechanical / Plumbing Design/Builder
1717 E. 116th Street, Suite 200
Carmel, Indiana 46032
317-580-0402
Kimley Horn
250 East 96th Street, Suite 580
Indianapolis, Indiana 46240
DEEM LLC
6831 E 32nd Street
Indianapolis, Indiana 46226
KEY PLAN
B
A
HOTEL
PROJECT NO.
SHEET ISSUE
SEAL | DATE
COPYRIGHT NOTICE: THIS ARCHITECTURAL
AND ENGINEERING DRAWING IS GIVEN IN
CONFIDENCE AND SHALL BE USED ONLY
PURSUANT TO THE AGREEMENT WITH RATIO.
NO OTHER USE, DISSEMINATION OR
DUPLICATION MAY BE MADE WITHOUT PRIOR
WRITTEN CONSENT OF RATIO. ALL COMMON
LAW RIGHTS OF COPYRIGHT AND OTHERWISE
ARE HEREBY SPECIFICALLY RESERVED.
TRAINING
CENTER
**-ALL DRAWINGS MARKED AS PART OF AN "EARLY"
SUBMISSION PACKAGE ARE ISSUED PRIOR TO COMPLETION OF
OTHER DESIGN DISCIPLINES INCLUDING BUT NOT LIMITED TO
ARCHITECTURAL OR MECHANICAL DESIGNS; AND AS SUCH,
ARE INCOMPLETE BY NATURE FOR THE COMPREHENSIVE
SCOPE OF THE PROJECT. ALLOWANCES FOR STRUCTURAL
ELEMENTS REQUIRED DUE TO THE COMPLETION AND
CROSS-COORDINATION OF ALL OTHER DISCIPLINES SHOULD
BE MADE.
1717 EAST 116TH STREET | SUITE 200 | CARMEL, IN. 46032
(317) 580-0402 | WWW.O-N.com | Project No. 7167.0013.00
SHELL & CORE PERMIT SET
10/15/21
Electrical Design/Builder
Barth Electric Co., Inc.
1934 N. Illinois Street
Indianapolis, Indiana 46202
10/15/2021 2:23:14 PMS-103B
THIRD FLOOR & LOW
ROOF FRAMING
PLAN -AREA B
21040.000
Republic Airways
Training Center
12195 N. Meridian St.
Carmel, Indiana
46032
SCALE: 1/8" = 1'-0"
THIRD FLOOR & LOW ROOF FRAMING PLAN - AREA B
1 DESIGN DEVELOPMENT 10/01/21
2 CONSTRUCTION DOCUMENTS 10/15/21
10/15/21
10/19/22