HomeMy WebLinkAboutS-104A-HIGH ROOF FRAMING PLAN -AREA A1 2 3 4 5 6 7 8 A B C D 7.7 D.3 MATCHLINE S-104B 9'-9" 29'-2" 20'-10" 18'-8" 39'-6" 39'-6" 28'-9 7/8" 10'-3 1/8"45'-7" 45'-8" 46'-6 5/8" 6'-5 3/8"196'-6" W18x40 W18x40 W24x68 W24x68 W24x68W24x68 W24x68 W24x68W30x90 W30x90 W30x90W30x90 W30x90 W30x90W18x40 W18x40 W18x40 W18x40 W18x40 W18x40 W18x40 W18x40 W18x40 W18x40 W18x40 W18x40 W18x40 W18x40 W18x40 W18x40 W18x40 W18x40 W18x40 W18x40 W18x40 W18x40 W18x40 W18x40 W18x40 W18x40 W18x40 W18x40 W18x40 W18x40 W18x40 W18x40 W18x40 W18x40 W18x40 W18x40 W18x40 16k16k 16k 16k16k 16k 16kT.O.S. EL. + 148'-2 7/8"T.O.S. EL. + 147'-0 1/16"(TYP. ALONG GRID 8)(TYP. ALONG GRID 5)31k31k 31k 18k31k 31k 31k31k31k 31k 18k31k 31k 31k16k16k 16k 16k16k 16k 16k 17k17k DB DB1 S-402 4 S-402 2 S-402 1 S-402 3 S-402 3 S-402 W8x24 W8x24 HSS10x4x1/4E.O.D.5"E.O.D. 11" E.O.D. 6" NOTES: 1) TOP OF STEEL/DECK BEARING ELEVATION (+VARIES), SEE PLAN. 2) INDICATES 3", 22 GA. TYPE 'N' METAL ROOF DECK. 6) INDICATES VERTICAL DIAGONAL BRACING, SEE S-501 FOR ADDITIONAL INFORMATION. 4) ALL BEAM/GIRDER CONNECTIONS SHALL BE DESIGNED FOR A MINIMUM UNFACTORED VERTICAL REACTION OF 15 kips, UNLESS NOTED GREATER. CONNECTIONS TO COLUMNS TO BE PER GENERAL NOTES. ALL REACTIONS SHOWN ON PLAN ARE SERVICE LOADS. D1 DB SS ROC PROFE.AI GNNIOLAE RER SASTATE OF 860325 NNID No. A ENI R M IED EG N TSE Y MOC DE c SHEET TITLE SHEET NUMBER RATIO 101 South Pennsylvania Street Indianapolis, Indiana 46204 317-633-4040 Architect McComas/O'Donnell & Naccarato Structural Engineer Civil Engineer Mechanical / Plumbing Design/Builder 1717 E. 116th Street, Suite 200 Carmel, Indiana 46032 317-580-0402 Kimley Horn 250 East 96th Street, Suite 580 Indianapolis, Indiana 46240 DEEM LLC 6831 E 32nd Street Indianapolis, Indiana 46226 KEY PLAN B A HOTEL PROJECT NO. SHEET ISSUE SEAL | DATE COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE, DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED. TRAINING CENTER **-ALL DRAWINGS MARKED AS PART OF AN "EARLY" SUBMISSION PACKAGE ARE ISSUED PRIOR TO COMPLETION OF OTHER DESIGN DISCIPLINES INCLUDING BUT NOT LIMITED TO ARCHITECTURAL OR MECHANICAL DESIGNS; AND AS SUCH, ARE INCOMPLETE BY NATURE FOR THE COMPREHENSIVE SCOPE OF THE PROJECT. ALLOWANCES FOR STRUCTURAL ELEMENTS REQUIRED DUE TO THE COMPLETION AND CROSS-COORDINATION OF ALL OTHER DISCIPLINES SHOULD BE MADE. 1717 EAST 116TH STREET | SUITE 200 | CARMEL, IN. 46032 (317) 580-0402 | WWW.O-N.com | Project No. 7167.0013.00 SHELL & CORE PERMIT SET 10/15/21 Electrical Design/Builder Barth Electric Co., Inc. 1934 N. Illinois Street Indianapolis, Indiana 46202 10/15/2021 2:23:16 PMS-104A HIGH ROOF FRAMING PLAN - AREA A 21040.000 Republic Airways Training Center 12195 N. Meridian St. Carmel, Indiana 46032 SCALE: 1/8" = 1'-0" HIGH ROOF FRAMING PLAN - AREA A 1 DESIGN DEVELOPMENT 10/01/21 2 CONSTRUCTION DOCUMENTS 10/15/21 10/15/21 10/19/22