HomeMy WebLinkAboutS-200 - GENERAL NOTESGENERAL CONSTRUCTION
1. NOTES, TYPICAL DETAILS, AND SCHEDULES APPLY TO ALL STRUCTURAL WORK UNLESS NOTED OTHERWISE. TYPICAL DETAILS ARE TO BE
USED FOR ALL CONDITIONS WHERE THE DETAIL IS APPLICABLE, WHETHER OR NOT NOTED ON PLAN. TYPICAL DETAILS MAY BE SLIGHTLY ALTERED IF
REQUIRED DUE TO PROJECT CONDITIONS, ONLY WHEN SUBMITTED AND THE ENGINEER’S APPROVAL IS OBTAINED PRIOR TO PERFORMING THE WORK.
2. ALL DIMENSIONS AND ELEVATIONS SHOWN ON STRUCTURAL DRAWINGS, WITH THE EXCEPTION OF STRUCTURAL MEMBER SIZES, ARE
GENERATED BY OTHER DISCIPLINES. ANY DIMENSIONS OR ELEVATIONS OMITTED OR NOT SHOWN ON THE STRUCTURAL DRAWINGS SHOULD BE
OBTAINED FROM THE DRAWINGS OF THE OTHER DISCIPLINES. STRUCTURAL DRAWINGS ARE NOT “STAND-ALONE”DOCUMENTS AND SHOULD BE USED
IN CONJUNCTION WITH, AND COORDINATED WITH THE SPECIFICATIONS, ARCHITECTURAL DRAWINGS AND ALL OTHER DISCIPLINE’S DRAWINGS. IF
THERE IS A DISCREPANCY BETWEEN DRAWINGS, IT IS THE CONTRACTOR’S RESPONSIBILITY TO NOTIFY THE ENGINEER AND ARCHITECT PRIOR TO
PERFORMING THE WORK.
3. IF DIFFERENCES OCCUR WITHIN OR BETWEEN DRAWINGS AND SPECIFICATIONS REGARDING MATERIALS, STRENGTHS OR QUANTITIES, THE
BETTER MATERIAL, HIGHER STRENGTH, AND GREATER QUANTITY INDICATED, SPECIFIED OR NOTED SHALL BE PROVIDED.
4. REPRODUCTIONS OF STRUCTURAL DRAWINGS FOR SUBMITTAL AS SHOP DRAWINGS IS PROHIBITED, UNLESS WRITTEN APPROVAL IS
REQUESTED BY THE CONTRACTOR AND IT IS GRANTED BY O’DONNELL & NACCARATO, INC.
5. DO NOT SCALE DRAWINGS TO OBTAIN DIMENSIONAL INFORMATION.
6. THESE DRAWINGS DO NOT DEFINE SCOPE OF CONTRACTOR OR SUBCONTRACTOR CONTRACTS.
7. AT ALL TIMES, THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR THE CONDITIONS OF THE JOBSITE INCLUDING MEANS AND METHODS OF
CONSTRUCTION AND SAFETY OF PERSONS AND PROPERTY. THE ENGINEER’S PRESENCE OR REVIEW OF WORK AT THE JOBSITE IS FOR GENERAL
COMPLIANCE WITH THE DESIGN INTENT ONLY AND IS NOT EVER TO BE CONSTRUED AS A REVIEW OF MEANS AND METHODS OF CONSTRUCTION AND
SAFETY METHODS.
8. THE CONTRACTOR IS RESPONSIBLE FOR DETERMINING ALLOWABLE CONSTRUCTION LOADS AND FOR PROTECTING THE COMPLETED OR
INCOMPLETE STRUCTURAL FRAMING FROM DAMAGE DUE TO TEMPORARY CONSTRUCTION LOADINGS.
9. COSTS OF INVESTIGATION AND/OR REDESIGN DUE TO CONTRACTOR ERRORS WILL BE AT THE CONTRACTOR’S EXPENSE.
10. ANY APPROVED CONTRACTOR REQUESTED CHANGES TO THESE DRAWINGS WILL BE DONE AT NO COST TO THE OWNER. APPROVAL OF
CONTRACTOR REQUESTED CHANGES IN NO WAY STATES OR IMPLIES APPROVAL OF A CHANGE IN SCOPE OR CHANGE IN CONTRACT COST.
11. UNLESS EXPLICITLY NOTED AS “ISSUED FOR BID”, THESE DRAWINGS ARE NOT SUITABLE FOR OBTAINING BIDS FROM GENERAL OR
SUBCONTRACTORS. BIDDING OF DRAWINGS PRIOR TO DESIGN COMPLETION AND “ISSUED FOR BID”IS DONE AT THE SOLE RISK OF THE BIDDING
CONTRACTOR. ADDITIONS OR CORRECTIONS TO DRAWINGS THAT ARE BID PRIOR TO DESIGN COMPLETION AND “ISSUED FOR BID”WILL NOT BE
CONSIDERED AS DESIGN ERRORS OR OMISSIONS. STRUCTURAL DESIGN, BY NATURE, CANNOT BE COMPLETE PRIOR TO COMPLETION OF
ARCHITECTURAL AND MECHANICAL DRAWINGS.
12. ALL REFERENCES TO WATER/DAMPPROOFING, FIREPROOFING, AND UTILITIES ON THE STRUCTURAL DRAWINGS ARE FOR REFERENCE ONLY.
SEE ARCHITECTURAL DRAWINGS, SPECIFICATIONS, AND OTHER DOCUMENTS FOR ALL WATER/DAMPPROOFING, FIREPROOFING AND UTILITY DETAILS
AND REQUIREMENTS. COORDINATE ALL UNDERGROUND UTILITY REQUIREMENTS WITH THE CIVIL/MEP DRAWINGS. ALL UTILITIES SHALL BE
ABOVE/BELOW FOOTING AND NOT LOCATED WITHIN THE FOOTINGS. NOTIFY ENGINEER OF RECORD IF OTHERWISE
13. IF THE EXISTING FIELD CONDITIONS DO NOT PERMIT THE INSTALLATION OF THE WORK IN ACCORDANCE WITH THE DETAILS SHOWN, THE
CONTRACTOR SHALL NOTIFY THE ARCHITECT/ENGINEER IMMEDIATELY. THE CONTRACTOR MUST PROVIDE A SKETCH OF THE CONDITION WITH HIS
PROPOSED MODIFICATION OF THE DETAILS GIVEN ON THE CONTRACT DOCUMENTS. THIS SKETCH MUST BE SUBMITTED TO AND APPROVAL MUST BE
GRANTED BY THE ENGINEER PRIOR TO PERFORMING THE WORK.
14. SUBMIT SHOP DRAWINGS SUCH THAT BY THE TIME THEY ARE RECEIVED BY O’DONNELL & NACCARATO, INC., THERE WILL BE AT LEAST 14 DAYS
BEFORE REVIEWED SUBMITTALS WILL BE NEEDED. SHOP DRAWINGS SHALL BEAR THE CONTRACTOR’S STAMP OF APPROVAL CERTIFYING THAT HE
HAS VERIFIED ALL FIELD MEASUREMENTS, CONSTRUCTION CRITERIA, MATERIALS AND SIMILAR DATA AND HAS CHECKED EACH DRAWING FOR
COMPLETENESS, COORDINATION AND COMPLIANCE WITH THE CONTRACT DOCUMENTS. IF REVIEW OF AN INCOMPLETE SHOP DRAWING IS REQUIRED,
THAT SHOP DRAWING SHALL BE CLEARLY MARKED AS INCOMPLETE. THE AREA THAT NEEDS TO BE REVIEWED SHALL BE CLEARLY NOTED WITH AN
EXPLANATION FOR THE REASON FOR PARTIAL APPROVAL.
15. IN NO CASE SHALL HEAVY EQUIPMENT BE PERMITTED CLOSER THAN 8’-0” FROM ANY FOUNDATION/BASEMENT WALL. IF THE CONTRACTOR
DEEMS IT NECESSARY TO OPERATE SUCH EQUIPMENT CLOSER THEN 8’-0”, THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE AND, AT HIS OWN
EXPENSE, PROVIDE ADEQUATE SUPPORTS OR WALL BRACES TO WITHSTAND THE ADDITIONAL LOADS SUPERIMPOSED FROM SUCH EQUIPMENT.
16. SIZE AND/OR LOCATION OF OPENINGS, SLEEVES, CONCRETE HOUSEKEEPING PADS, INSERTS, DEPRESSIONS, ETC. SHOWN ON THE STRUCTURAL
DOCUMENTS ARE FOR THE CONTRACTOR’S CONVENIENCE ONLY. THE CONTRACTOR IS SOLELY RESPONSIBLE TO COORDINATE ALL CONTRACT
DOCUMENTS TO DETERMINE THE SIZE AND/OR LOCATION OF OPENINGS, SLEEVES, CONCRETE HOUSEKEEPING PADS, INSERTS, DEPRESSIONS, ETC.
17. SIZE AND/OR LOCATION OF EXISTING STRUCTURES AND UTILITIES SHOWN ON THE STRUCTURAL DOCUMENTS ARE FOR THE CONTRACTOR’S
CONVENIENCE ONLY. THE CONTRACTOR IS SOLELY RESPONSIBLE TO VERIFY BY FIELD MEASUREMENTS/INVESTIGATION THE SIZE AND/OR LOCATION
OF ALL EXISTING STRUCTURES AND UTILITIES.
18. THE CONTRACTOR SHALL SUBMIT SIGNED AND SEALED CALCULATIONS AND SHOP DRAWINGS BY A STRUCTURAL ENGINEER REGISTERED IN
THE STATE IN WHICH THE PROJECT IS LOCATED SHOWING DESIGNS OF METAL STAIRS, METAL RAILINGS AND CONNECTIONS TO STRUCTURE TAKING
INTO ACCOUNT THE VERTICAL AND LATERAL LOADS STATED IN THE GOVERNING CODES. WHERE HEADERS OR OTHER TYPES OF STRUCTURAL
MEMBERS HAVE BEEN DESIGNATED ON THE STRUCTURAL CONTRACT DOCUMENTS TO SUPPORT THE STAIRS, THE CONNECTIONS FROM THE STAIRS
SHALL BE DESIGNED SO THAT NO ECCENTRIC OR TORSIONAL FORCES ARE IMPOSED ON THESE STRUCTURAL MEMBERS. IF ECCENTRIC
CONNECTIONS ARE USED, CONTRACTOR SHALL PROVIDE BRACING ELEMENTS FOR ALL SUPPORTING STEEL TO ELIMINATE THE TORSIONAL EFFECTS
OF THE ECCENTRIC CONNECTIONS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR FURNISHING AND INSTALLING ALL EMBEDDED ITEMS AND
HARDWARE AS REQUIRED PER THE STAIR DESIGN.
19. STRUCTURAL COMPONENTS ARE NOT DESIGNED FOR VIBRATING EQUIPMENT. MOUNT VIBRATING EQUIPMENT ON VIBRATION ISOLATORS,
INERTIA PADS, ETC.
20. EXACT LOCATIONS OF ROOF PENETRATIONS TO BE COORDINATED BY THE GENERAL CONTRACTOR BETWEEN STEEL/JOIST/DECK/HVAC
SUBCONTRACTORS. SEE DETAIL FOR ROOF FRAME REQUIREMENTS
EXISTING CONDITIONS/DEMOLITION
1. SHORING, BRACING, PROTECTION, AND UNDERPINNING OF EXISTING AND ADJACENT STRUCTURES DURING CONSTRUCTION, INCLUDING ALL
DESIGN RESPONSIBILITIES, IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR. PROVIDE SIGNED AND SEALED CALCULATIONS AND DRAWINGS TO
OWNER. PROTECT AND MAINTAIN THE INTEGRITY OF EXISTING AND ADJACENT STRUCTURES, BUILDINGS AND STREETS,
2. ALL EXISTING DIMENSIONS, ELEVATIONS, AND LOCATIONS OF EXISTING STRUCTURES, OR RELATIVE TO EXISTING STRUCTURES, THAT ARE
SHOWN ON THE STRUCTURAL DOCUMENTS WILL BE VERIFIED BY FIELD MEASUREMENTS PERFORMED BY THE CONTRACTOR. ANY DISCREPANCIES
SHALL BE REPORTED TO THE ARCHITECT AND ENGINEER.
3. THE STRUCTURAL DOCUMENTS HAVE BEEN PREPARED BASED ON AVAILABLE KNOWLEDGE OF EXISTING CONDITIONS. IF, DURING DEMOLITION,
EXCAVATION OR CONSTRUCTION, ACTUAL CONDITIONS ARE DISCOVERED TO DIFFER FROM THOSE INDICATED ON THE DOCUMENTS, THE ARCHITECT
AND ENGINEER SHALL BE NOTIFIED.
4. ALL STRUCTURAL DEMOLITION MUST BE COORDINATED WITH THE ARCHITECTURAL, MECHANICAL, ELECTRICAL, AND PLUMBING DRAWINGS.
5. SELECTIVELY DEMOLISH STRUCTURAL COMPONENTS AS REQUIRED TO CONSTRUCT NEW WORK. PRIOR TO ANY DEMOLITION WORK, AN
ENGINEERING SURVEY REPORT OF THE STRUCTURE SHALL BE PREPARED BY THE CONTRACTOR TO DOCUMENT THE CONDITION OF THE FRAMING,
FLOORS, AND WALLS. ANY ADJACENT STRUCTURE WHERE OCCUPANTS MAY BE EXPOSED SHALL BE SIMILARLY REVIEWED.
6. WHERE NEW FRAMING IS TO BE CONNECTED TO AN EXISTING STRUCTURE WITH BRICK OR CMU VENEER, THE VENEER SHALL BE REMOVED
SUFFICIENTLY TO PERMIT CONNECTION OF THE NEW FRAMING DIRECTLY TO THE BUILDING SUPERSTRUCTURE. NEW BRICK OR CMU SHALL BE
INSTALLED TO MATCH THE EXISTING ADJACENT SURFACES. MAINTAIN A 1/2" SEPARATION BETWEEN THE BRICK OR CMU AND THE NEW FRAMING,
UNLESS NOTED OTHERWISE ON DRAWINGS. FILL GAPS WITH BACKER RODS AND SEALANTS.
7. CONTRACTOR TO FIELD VERIFY ALL EXISTING FINISHED FLOOR ELEVATIONS PRIOR TO FABRICATION OF STEEL BEGINS. PROVIDE ALLOWANCE
FOR ADDITIONAL LEVELING MATERIAL IN AREAS OF BREAK THROUGH TO THE EXISTING STRUCTURE TO ENSURE FINISHED FLOOR ELEVATION OF NEW
MATCHES EXISTING.
8. CONTRACTOR SHALL RETAIN INDIVIDUAL TO PERFORM SITE SAFETY DEMOLITION PLAN, ENGINEERING STUDY AND ALL OTHER SERVICES
RELATED TO DEMOLITION IN ACCORDANCE WITH LOCAL JURISDICTION REQUIREMENTS.
FOUNDATIONS
1. PERFORM ALL SITE PREPARATION AND EXCAVATION WORK IN STRICT ACCORDANCE WITH THE GEOTECHNICAL ENGINEERING REPORT AS
PREPARED BY TBD (N1, DATED N2).
2. EXCAVATE THE BUILDING SITE TO THE DEPTH AND EXTENT INDICATED IN THE SOILS REPORT. ALL SUBGRADES SHALL BE APPROVED IN
WRITING BY THE SOILS ENGINEER PRIOR TO BACKFILLING.
3. NO GEOTECHNICAL REPORT IS PROVIDED. BOTTOM OF FOOTINGS IS ASSUMED TO BEAR ON SOIL CAPABLE OF SAFELY SUPPORTING 5000 PSF.
PRIOR TO CONSTRUCTION, THE SERVICES OF A QUALIFIED GEOTECHNICAL ENGINEER SHALL BE RETAINED. THE GENERAL CONTRACTOR IS HEREIN
RESPONSIBLE FOR PERFORMING ALL EARTHWORK OPERATIONS IN STRICT ACCORDANCE WITH GEOTECHNICAL ENGINEERING REQUIREMENTS. IF THE
FOUNDATION RECOMMENDATIONS AND/OR DESIGN VALUES DIFFER FROM THAT ASSUMED, MODIFICATION TO THE DESIGN/DRAWINGS MAY BE
REQUIRED.
4. BOTTOM OF FOOTINGS SHALL BEAR ON SUBGRADE CAPABLE OF SAFELY SUPPORTING 5000 PSF PER THE GEOTECHNICAL REPORT. MODIFY
SOIL BEARING CAPACITY USING RAMMED AGGREGATE PIER (RAP) TECHNIQUES. SOIL SHALL BE MODIFIED TO ACHIEVE THE MINIMUM ALLOWABLE
BEARING CAPACITY STATED. RAMMED AGGREGATE PIERS SHALL BE DESIGN BY APPROVED CONTRACTOR.
5. SUBGRADE OF ALL FOOTINGS MUST BE INSPECTED UNDER THE SUPERVISION OF AND APPROVED BY A REGISTERED SOILS ENGINEER BEFORE
PLACING ANY CONCRETE. APPROVAL IN WRITING MUST INDICATE THE SOIL IS ADEQUATE TO SAFELY SUSTAIN SPECIFIED SOIL BEARING PRESSURE.
6. BOTTOM OF ALL EXTERIOR FOOTINGS SHALL BE A MINIMUM OF 3 FEET BELOW EXTERIOR FINISH GRADE. ALL FOOTING ELEVATIONS SHOWN ON
PLAN ARE THE BEST APPROXIMATIONS BASED ON AVAILABLE DATA. GENERAL CONTRACTOR MAY ALTER FOOTING ELEVATIONS FOR REASONS
INCLUDING, BUT NOT LIMITED TO, REVISED GEOTECHNICAL OR CIVIL INFORMATION, UNFORESEEN CONDITIONS, ACTUAL INVERT ELEVATIONS,
CONTRACTIBILITY, ETC. CONTRACTOR SHALL NOTIFY ARCHITECT AND OBTAIN WRITTEN APPROVAL PRIOR TO ANY MODIFICATIONS.
7. DO NOT BACKFILL ANY BASEMENT WALLS WITH AN UNBALANCED HEIGHT OF SOIL GREATER THAN THREE FEET UNTIL ELEVATED FLOOR IS IN-
PLACE AND THE WALL HAS REACHED ITS DESIGN STRENGTH OR THE WALLS ARE ADEQUATELY BRACED.
8. CONCRETE/CMU WALLS EXPOSED TO VIEW (INTERIOR OR EXTERIOR) SHALL HAVE CONTROL JOINTS AT 30 FEET MAXIMUM ON CENTER UNLESS
NOTED OTHERWISE. WALLS WITH INTEGRAL COLUMN PIERS OR PILASTERS SHALL BE POURED MONOLITHICALLY AND SHALL HAVE A FORMED
CONTROL JOINT ON ONE SIDE OF EACH PIER ON THE EXPOSED FACE OF THE WALL. JOINTS SHALL BE FILLED WITH AN APPROVED SEALANT.
CONCRETE
1. REINFORCING STEEL SHALL BE WITHIN TOLERANCES SET FORTH IN ACI 117, AND HAVE THE SPECIFIED CLEAR COVER, UNLESS NOTED
OTHERWISE ON DRAWINGS:
CONCRETE POURED AGAINST EARTH 3"
CONCRETE EXPOSED TO EARTH OR WEATHER:
#5 OR SMALLER 1 1/2"
#6 OR LARGER 2"
CONCRETE NOT EXPOSED TO WEATHER OR IN CONTACT WITH GROUND:
COLUMNS (TIES AND MAIN REINFORCING) 1 1/2"
SLABS, WALLS, JOISTS: #14 OR #18 BARS 1 1/2"
#11 OR SMALLER 3/4"
BEAMS (STIRRUPS AND MAIN REINFORCING) 1 1/2"
CLEAR COVER SHALL BE CLEARLY SHOWN ON ALL REINFORCING BAR DETAIL DRAWINGS.
2. ALL CONCRETE SHALL BE READY-MIX AND HAVE A MINIMUM COMPRESSIVE STRENGTH AT 28 DAYS OF:
A. SPREAD FOOTINGS/WALL FOOTINGS/FOUNDATION WALL 3,000 PSI
B. BASEMENT WALLS/RETAINING WALLS 4,000 PSI
C. PIERS-MATCH WALL STRENGTH (MINIMUM OF 4,000 PSI)
D. SLAB-ON-GRADE 4,000 PSI
E. COLUMNS FRAMING 6,000 PSI AT 7 DAYS
F. STRUCTURAL SLABS 6,000 PSI AT 7 DAYS
G. CONCRETE SLABS ON METAL DECK 4,000 PSI
H. OR AS SHOWN ON DRAWINGS.
I. HAVE A MINIMUM OF 500 LBS. OF CEMENT PER CUBIC YARD.
J. SLUMP (AT POINT OF CONCRETE PLACEMENT) SHALL BE 3 INCH MINIMUM AND 6 INCH MAXIMUM.
K. CONCRETE EXPOSED TO WEATHER SHALL HAVE 5 PERCENT AIR ENTRAINMENT. CONCRETE NOT EXPOSED TO WEATHER SHALL NOT CONTAIN
AN AIR-ENTRAINING AGENT.
L. SUBMIT MIX DESIGNS FOR REVIEW.
NORMAL-WEIGHT CONCRETE TO BE GIVEN A HARD-TROWELED FINISH SHALL NOT CONTAIN AN AIR-ENTRAINING AGENT. TOTAL AIR CONTENT
FOR THIS CONCRETE SHOULD NOT EXCEED 3 PERCENT (AT POINT OF CONCRETE PLACEMENT). ALL CONCRETE WORK SHALL COMPLY WITH THE
REQUIREMENTS OF THE LATEST ACI BUILDING CODE (ACI 318), THE ACI DETAILING MANUAL (ACI 315), AND THE SPECIFICATIONS FOR STRUCTURAL
CONCRETE FOR BUILDINGS (ACI 301).
3. ALL REINFORCING STEEL SHALL BE MANUFACTURED FROM HIGH STRENGTH BILLET STEEL CONFORMING TO ASTM DESIGNATION
A615 GRADE 60.
4. DEVELOPMENT LENGTHS, NOTED AS Ld ON DRAWINGS, AND SPLICE/LAP LENGTHS OF ALL REINFORCING STEEL TO BE PER DETAIL WITH NOTES
ENTITLED "TABLE OF DEVELOPMENT AND LAP SPLICE LENGTH". LAP SPLICES OF #14 BARS AND LARGER ARE NOT PERMITTED. THESE BARS MUST BE
MECHANICALLY COUPLED WITH DEVICES RATED TO DEVELOP 125% OF Fy OF THE BAR. SUBMIT PRODUCT DATA FOR ENGINEERING APPROVAL.
LAP ALL WWF A MINIMUM OF SIX INCHES.
5. ALL INSERTS AND SLEEVES SHALL BE CAST-IN-PLACE. THE CONTRACTOR SHALL VERIFY THE DIMENSIONS AND LOCATIONS OF ALL OPENINGS,
PIPE SLEEVES, ETC. AS REQUIRED BY ALL TRADES BEFORE THE CONCRETE IS POURED. THE CONTRACTOR SHALL CONSULT THE ARCHITECTURAL,
MECHANICAL, AND ELECTRICAL DRAWINGS, AS WELL AS THE STRUCTURAL DRAWINGS FOR THE LOCATION, NUMBER, AND SIZE OF ALL OPENINGS,
SLEEVES, ETC. HOWEVER, OPENINGS NOT SHOWN ON THE STRUCTURAL DRAWINGS SHALL BE INSTALLED ONLY AFTER APPROVAL BY THE
STRUCTURAL ENGINEER IS OBTAINED. DRAWINGS SHALL BE SUBMITTED FOR REVIEW SHOWING LOCATIONS AND DIMENSIONS OF ALL OPENINGS,
SLEEVES, ETC. IN CAST-IN-PLACE CONCRETE SLABS, BEAMS, WALLS, COLUMNS, AND FOUNDATIONS. THESE DRAWINGS SHALL BE COORDINATED BY
THE CONTRACTOR. OPENINGS AND SLEEVES THROUGH CAST-IN-PLACE CONCRETE FRAMING IS PROHIBITED EXCEPT WHERE THOSE SLEEVES AND
OPENINGS ARE SHOWN ON THE STRUCTURAL DRAWINGS OR WHERE THEY ARE SHOWN ON THE APPROVED SLEEVE AND OPENING DRAWINGS THAT
HAVE BEEN SUBMITTED TO THE STRUCTURAL ENGINEER FOR REVIEW. SAW-CUTTING, CORING, OR DRILLING OF SLEEVES OR OPENING THROUGH
PREVIOUSLY CAST CONCRETE IS NOT PERMITTED EXCEPT WHERE SPECIFICALLY REVIEWED AND APPROVED BY THE STRUCTURAL ENGINEER.
6. LOCATION OF CONSTRUCTION JOINTS IN THE STRUCTURAL SLAB SHALL BE SUBMITTED FOR APPROVAL BY THE STRUCTURAL ENGINEER.
CONSTRUCTION JOINTS IN STRUCTURAL SLABS SHALL BE AT MID-SPAN AND KEY JOINTED WITH REINFORCING CONTINUOUS ACROSS JOINT.
CONSTRUCTION JOINTS IN SLABS ON METAL DECK SHALL OCCUR MIDWAY BETWEEN BEAMS AT END THIRD OF GIRDER SPAN.
7. SUBMIT ALL REINFORCING SHOP DRAWINGS FOR REVIEW PRIOR TO ANY FABRICATION.
8. FOR CONCRETE SLABS ON METAL DECK, FLOORS SHALL BE POURED TO THE THICKNESS SHOWN ON DOCUMENTS, NOT TO A LEVEL LINE.
9. THE CONTRACTOR SHALL INSTALL FLOOR LEVELING MATERIAL AND PERFORM OTHER CORRECTIVE MEASURES IN ALL AREAS, INCLUDING BUT
NOT LIMITED TO, AREAS WHERE FLOOR FINISH PROVISIONS DO NOT COMPLY WITH THE FLATNESS AND LEVELNESS REQUIREMENTS. NOTE: UNLESS
NOTED OTHERWISE, THE CALCULATED CENTER OF BAY DEFLECTION DUE TO DEAD LOADS ONLY, MEASURED ON A DIAGONAL DIMENSION BETWEEN
COLUMNS, IS APPROXIMATELY 1/8”PER 10’-0”LENGTH.
10. CONTRACTOR TO ENGAGE AN ENGINEER, REGISTERED IN THE PROJECT'S JURISDICTION, TO DEVELOP ALL FORMWORK, SHORING, AND
RESHORING DESIGNS AND PROCEDURES AND SUBMIT SIGNED AND SEALED DRAWINGS AND CALCULATIONS. ALL SHORING AND RESHORING MUST
REMAIN IN PLACE FOR A MINIMUM OF 28 DAYS AFTER CONCRETE PLACEMENT, OR WHEN FULL STRENGTH IS ACHIEVED FROM FIELD CURED
CYLINDERS.
11. THE CONTRACTOR SHALL DELIVER TO THE ENGINEER, AT THE END OF THE JOB, ONE (1) ELECTRONIC VERSION OF THE FINAL FIELD COPIES OF
ALL STEEL REINFORCING SHOP DRAWINGS.
12. RIGID INSULATION USED AS FLOOR FILL SHALL BE STYROFOAM HIGHLOAD 40 EXTRUDED POLYSTYRENE INSULATION (40 PSI COMPRESSIVE
STRENGTH) ASTM C578, TYPE VI MANUFACTURED BY DOW CHEMICAL COMPANY, OR APPROVED EQUAL.
STEEL
1. ALL STRUCTURAL STEEL SHALL BE FABRICATED AND ERECTED IN ACCORDANCE WITH THE LATEST AISC 360-10.
ALL CONNECTIONS, INCLUDING AT HSS SECTIONS, SHALL BE DESIGNED AND DETAILED IN ACCORDANCE WITH THE LATEST AISC 360-10. UNLESS
INDICATED OTHERWISE ON CONTRACT DOCUMENTS, IN ADDITION TO THE SHEAR CONNECTION, INCLUDE AS A MINIMUM, 4X4X3/8 ANGLES TOP AND
BOTTOM OR ENDPLATE AT ALL HSS BEAMS/GIRDERS TO COLUMN CONNECTIONS. ALL WIDE FLANGE SHAPES SHALL BE ASTM A992. ALL OTHER
STRUCTURAL STEEL SHALL BE ASTM A36. UNLESS NOTED OTHERWISE. ALL STEEL RECTANGULAR/SQUARE HOLLOW STRUCTURAL SECTIONS SHALL
BE ASTM A500 GRADE C, FY = 50 KSI. ALL STEEL ROUND HOLLOW STRUCTURAL SECTIONS SHALL BE ASTM A500 GRADE C, FY = 46 KSI.
ALL STEEL SHALL HAVE A SHOP COAT OF RUST INHIBITIVE PAINT. ALL STEEL SHALL BE UNPAINTED. DELETE PAINT ON ALL STEEL TO RECEIVE
SPRAYED-ON FIREPROOFING OR CONCRETE ENCASEMENT, AS NOTED ON ARCHITECTURAL DOCUMENTS.
ORIENT ALL MILL CAMBER UPWARD DURING FABRICATION AND ERECTION. ALL STEEL SHALL BE THOROUGHLY CLEANED IN ACCORDANCE WITH SSPC-
SP3 PRIOR TO PAINTING.
2. ALL SHOP AND FIELD WELDING SHALL BE PERFORMED BY CERTIFIED WELDERS, AS DESCRIBED IN "AMERICAN WELDING SOCIETY'S STANDARD
QUALIFICATION PROCEDURE", AWS D1.1 LATEST EDITION, TO PERFORM THE TYPE OF WORK REQUIRED.
3. UNLESS OTHERWISE NOTED, ALL CONNECTIONS SHALL BE BOLTED WITH MINIMUM 3/4-INCH DIAMETER A325 OR A490 HIGH STRENGTH BEARING
TYPE BOLTS OR WELDED. THE FABRICATOR IS RESPONSIBLE FOR THE SELECTION, DESIGN, AND DETAILING OF ALL CONNECTIONS, INCLUDING BUT
NOT LIMITED TO MOMENT CONNECTIONS, BRACED FRAME CONNECTIONS, AND TRUSS CONNECTIONS, NOT FULLY DETAILED ON THE CONTRACT
DRAWINGS. THIS INCLUDES TO DESIGN, DETAIL, FURNISH, AND INSTALL STIFFENERS, CONTINUITY PLATES, DOUBLER PLATES, OR OTHER NECESSARY
ADDITIONAL LOCAL STRENGTHENING MEASURES AS REQUIRED. MEMBER SIZES INDICATED ON THE DRAWINGS ARE BASED ON MEMBER BEHAVIOR
AWAY FROM CONNECTIONS.
USE FULL DEPTH DOUBLE ANGLE CONNECTIONS ON ALL GIRDER AND BEAM CONNECTIONS TO COLUMNS. BOLTS SHALL BE AT 3 INCH O/C VERTICALLY.
INFILL BEAM CONNECTIONS MAY BE ONE-SIDED CONNECTIONS, UNLESS NOTED OTHERWISE. ALL GRAVITY MOMENT CONNECTIONS SHALL BE BOLTED
WITH MINIMUM 3/4-INCH DIAMETER A325 OR A490 HIGH STRENGTH SLIP CRITICAL BOLTS OR WELDED.
UNLESS OTHERWISE NOTED, DETAILS INDICATED ON DRAWINGS INDICATE GENERAL CRITERIA FOR DESIGN AND DETAILING OF CONNECTIONS.
DETAILS INDICATED ON DRAWINGS ARE NOT INTENDED TO CONVEY COMPLETE CONNECTOR SIZES, PLATE SIZES, WELD SIZES, NUMBER OF BOLTS, OR
ANY OTHER SPECIFIC INFORMATION THAT IS OBTAINED THROUGH DESIGNING OF AN INDIVIDUAL CONNECTION FOR A GIVEN SET OF LOADS. THESE
DETAILS DO NOT SHOW ERECTION AIDS. PROVIDE ERECTION AIDS AS REQUIRED AND REMOVE THEM AFTER WORK IS COMPLETE.
4. ALL ANCHOR RODS TO BE ASTM F1554 GRADE 36, UNLESS NOTED OTHERWISE.
5. ALL ALUMINUM AND STEEL MEMBERS SHALL BE TREATED OR PROPERLY SEPARATED TO PREVENT GALVANIC AND CORROSIVE EFFECTS.
6. ALL STEEL WELDING RODS SHALL BE E70XX.
7. SUBMIT ALL STEEL SHOP DRAWINGS FOR REVIEW PRIOR TO ANY FABRICATION. SHOP DRAWINGS SHALL SHOW COMPLETE BOLTING AND
WELDING INFORMATION, BOTH SHOP AND FIELD. ALL WELDING INFORMATION SHALL USE AMERICAN WELDING SOCIETY SYMBOLS. SHOP OR FIELD
SPLICING OF ANY STRUCTURAL STEEL SECTION WHERE NOT DETAILED ON THE CONTRACT DOCUMENTS IS STRICTLY PROHIBITED WITHOUT PRIOR
WRITTEN APPROVAL BY THE STRUCTURAL ENGINEER OF RECORD.
8. CONNECTIONS FOR ALL BEAM/GIRDERS SHALL BE DESIGNED FOR A MINIMUM UNFACTORED REACTION OF 15 KIPS, UNLESS NOTED GREATER
ON DRAWINGS.
9. STEEL FABRICATOR IS SOLELY RESPONSIBLE FOR SURVEYING AND VERIFICATION OF EXISTING CONDITIONS INCLUDING BUT NOT LIMITED TO
THE LOCATION, ELEVATION, AND DIMENSIONS OF EXISTING WALLS AND FRAMING.
10. ALL LINTELS AND SHELF ANGLES WITHIN EXTERIOR WALLS SHALL BE HOT DIP GALVANIZED. ANY POINTS OF WELDING SHALL BE TOUCHED UP
IN THE FIELD WITH A ZINC-RICH PAINT BY THE STEEL ERECTOR.
11. ALL EXPOSED STEEL (INCLUDING BUT NOT LIMITED TO DUNNAGE FRAMING, SCREEN WALL FRAMING, CANOPY FRAMING, ETC.) SHALL BE HOT
DIP GALVANIZED. ANY POINTS OF WELDING SHALL BE TOUCHED UP IN THE FIELD WITH A ZINC-RICH PAINT BY THE STEEL ERECTOR.
12. SPANDREL ANGLE AT PERIMETER EDGE OF FLOOR SLAB/ROOF SHALL BE ADJUSTABLE. SHIP ANGLE LOOSE AND SET WITH STRING LINE IN
FIELD FOR VERTICAL AND HORIZONTAL ALIGNMENT AFTER STEEL IS FULLY ERECTED TO A MAXIMUM TOLERANCE OF 1/4 INCH HORIZONTAL PER
BAY/PER FLOOR AND MUST BE SET PLUMB BY STEEL ERECTOR PRIOR TO STUD ERECTION. ANGLE MUST BE INSTALLED IN ONE LENGTH PER BAY. SEE
TYPICAL SPANDREL ANGLE DETAIL.
13. PROVIDE WELDED STIFFENER PLATES ON BOTH SIDES OF THE WEB OF BEAMS AT POINTS OF CONCENTRATED LOADS INCLUDING BEAMS
SUPPORTING COLUMNS OR RUNNING OVER THE TOPS OF COLUMNS, OR OTHER BEAMS. MINIMUM STIFFENER PLATE THICKNESS SHALL BE 3/8 INCH OR
FLANGE THICKNESS OF COLUMN ABOVE OR BELOW OR BEAM WEB THICKNESS ABOVE OR BELOW, WHICHEVER IS GREATER.
14. ALL POST-INSTALLED EXPANSION ANCHORS FASTENED INTO CONCRETE SHALL BE HILTI KWIK BOLT TZ WITH MATERIAL TYPE, DIAMETER, AND
EMBEDMENT PER DOCUMENTS, UNLESS NOTED OTHERWISE. ALL POST-INSTALLED ADHESIVE ANCHORS FASTENED INTO CONCRETE AND
REINFORCING BAR DOWELING INTO CONCRETE SHALL USE HILTI HIT-RE 500v3 EPOXY ADHESIVE ANCHORING SYSTEM IN HAMMER-DRILLED HOLES
WITH ROD TYPE, DIAMETER, EMBEDMENT AND SPACING/EDGE DISTANCE PER DOCUMENTS, UNLESS NOTED OTHERWISE.
15. ALL PIPING RUNS LARGER THAN 4" DIAMETER SHALL BE HUNG DIRECTLY FROM STEEL BEAMS AND NOT THE CONCRETE SLAB ON METAL DECK
SYSTEM (NO UTILITIES SHALL BE HUNG FROM METAL ROOF DECK). ANY SUPPLEMENTAL STEEL REQUIRED FOR BUILDING SYSTEMS (MECHANICAL,
ELECTRICAL, PLUMBING, ETC.) IS NOT BY O'DONNELL & NACCARATO.
16. THE CONTRACTOR SHALL DELIVER TO THE ENGINEER, AT THE END OF THE JOB, ONE (1) ELECTRONIC VERSION OF THE FINAL FIELD COPIES OF
ALL STEEL ERECTION DRAWINGS SHOP DRAWINGS.
DECK
1. STEEL ROOF DECK SHALL BE PAINTED 3" 22 GAGE TYPE N METAL DECK, AS SHOWN ON DRAWINGS, GRADE 33 (MINIMUM FY = 33 KSI) AND
MANUFACTURED BY VULCRAFT OR APPROVED EQUAL. MANUFACTURER SHALL BE A MEMBER OF THE STEEL DECK INSTITUTE. ROOF DECK
FABRICATION AND INSTALLATION MUST COMPLY WITH STEEL DECK INSTITUTE STANDARDS. ALL ROOF DECK SHALL BE CONTINUOUS OVER A MINIMUM
OF THREE SPANS. SUSPENDED CEILINGS, LIGHT FIXTURES, DUCTS, PIPES (INCLUDING FIRE PROTECTION), OR OTHER UTILITIES SHALL NOT BE
SUPPORTED BY THE STEEL DECK.
2. ATTACH TYPE N METAL ROOF DECK TO STRUCTURAL STEEL SUPPORTS WITH 5/8" DIAMETER PUDDLE WELDS, OR EQUIVALENT MECHANICAL
FASTENER, (4 CONNECTIONS (MIN., UNO) PER 24" WIDE SHEET PER SUPPORT). FASTEN SIDE JOINTS TOGETHER WITH #10 SELF DRILLING SCREWS, OR
WELD, AT 3’-0”ON-CENTER MAXIMUM BETWEEN SUPPORTS.
3. USE WELDING WASHERS ON ALL CONNECTIONS OF STEEL DECK WITH METAL THICKNESS LESS THAN 22 GAGE TO STRUCTURAL STEEL
SUPPORTS.
4. IN AREAS OF WARPED ROOF DECK USE, SELF DRILLING SCREWS FOR CONNECTIONS OF STEEL ROOF DECK TO STRUCTURAL STEEL
SUPPORTS. SCREW SIZES SHALL COMPLY WITH MANUFACTURER'S REQUIREMENTS, ATTACH DECK TO ALL SUPPORTING MEMBERS.
5. HOTEL FLOOR DECK SHALL BE GALVANIZED 2" -22 GAGE EPICORE MSR COMPOSITE METAL DECK AS SHOWN ON DRAWINGS. MANUFACTURER
SHALL BE A MEMBER OF THE STEEL DECK INSTITUTE. FLOOR DECK FABRICATION AND INSTALLATION MUST COMPLY WITH STEEL DECK INSTITUTE
STANDARDS. STAGGER FLOOR DECK AT BEARING WALLS PER TYPICAL DETAIL ON S-401 FOR SOUND/STC REASONS. HOTEL FLOOR DECK SHORING
REQUIRED AT 5'-0" ON-CENTER MAXIMUM.
MINIMUM STC RATING = 55
MINIMUM IIC RATING = 57
6. ATTACH EPICORE MSR COMPOSITE METAL DECK TO STRUCTURAL STEEL SUPPORTS WITH 3/4" DIAMETER PUDDLE WELDS, OR EQUIVALENT
MECHANICAL FASTENER, (4 CONNECTIONS (MIN., UNO) PER 32" WIDE SHEET PER SUPPORT). FASTEN SIDE JOINTS WITH #10 SELF-DRILLING SCREW, OR
WELD, AT 3'-0" ON-CENTER MAXIMUM BETWEEN SUPPORTS AND AT 8" MAXIMUM AROUND PERIMETER .
7. BRIDGE FLOOR DECK SHALL BE GALVANIZED 3" -20 GAGE LOK-FLOOR COMPOSITE METAL DECK AS SHOWN ON DRAWINGS AND
MANUFACTURED BY VULCREAFT OR APPROVED EQUAL. MANUFACTURER SHALL BE A MEMBER OF THE STEEL DECK INSTITUTE. FLOOR DECK
FABRICATION AND INSTALLATION MUST COMPLY WITH STEEL DECK INSTITUTE STANDARDS. ALL FLOOR DECK SHALL BE CONTINUOUS OVER A
MINIMUM OF THREE SPANS. BRIDGE FLOOR DECK HAVE BEEN DESIGNED AS DESIGNED AS COMPOSITE DECK. BEAM/DECK SHORING IS NOT
REQUIRED.
8. COMPOSITE SHEAR STUDS SHALL BE WELDED THROUGH STEEL DECK. SHEAR STUDS SHALL BE HEADED STUDS MADE FROM LOW CARBON
STEEL, FY=60 KSI, CONFORMING TO ASTM A108 AND SHALL BE INSTALLED IN ACCORDANCE WITH AWS D1.1.
9. ATTACH LOK-FLOOR COMPOSITE METAL DECK TO STRUCTURAL STEEL SUPPORTS WITH 3/4" DIAMETER PUDDLE WELDS, OR EQUIVALENT
MECHANICAL FASTENER, (4 CONNECTIONS (MIN., UNO) PER 36" WIDE SHEET PER SUPPORT). FASTEN SIDE JOINTS WITH #10 SELF-DRILLING SCREW, OR
WELD, AT 3'-0" ON-CENTER MAXIMUM BETWEEN SUPPORTS.
10. NO CONDUIT SHALL BE PLACED WITHIN CONCRETE SLABS ON METAL DECK.
11. THE CONTRACTOR SHALL DELIVER TO THE ENGINEER, AT THE END OF THE JOB, ONE (1) ELECTRONIC VERSION OF THE FINAL FIELD COPIES OF
ALL DECK LAYOUT SHOP DRAWINGS.
LIGHTGAGE METAL FRAMING
1. LIGHTGAGE METAL STUD DESIGNATION SHOWN ON STRUCTURAL DRAWINGS ASSUME MARINO WARE AS A DESIGN BASIS. MANUFACTURER
MUST SUBMIT LITERATURE INDICATING THAT THE MEMBERS SUPPLIED PROVIDE EQUIVALENT STRENGTH AND STIFFNESS. MANUFACTURER AND/OR
SUPPLIER TO PREPARE INFORMATION INDICATING CAPACITY OF MEMBERS, FRAMING DETAILS, CONNECTIONS, BRACING, BRIDGING AND ALL OTHER
APPURTENANCES OF MEMBERS TO CONFORM TO LOAD CRITERIA AS DIRECTED BY CONTRACTOR/CONSTRUCTION MANAGER.
2. ALL STEEL STUDS SHALL BE HOT-DIPPED GALVANIZED (G 60) IN ACCORDANCE WITH ASTM A924. STEEL STUDS SHALL BE DESIGNED,
MANUFACTURED AND INSTALLED IN ACCORDANCE WITH THE LATEST AISC SPECIFICATIONS AND SHALL COMPLY WITH ASTM A653 & C955. ALL STUDS,
JOISTS, AND ACCESSORIES SHALL HAVE THE FOLLOWING MATERIAL STRENGTHS:
54 MILS (16 GAGE) AND HEAVIER -FY = 50KSI.
33 MILS, 43 MILS (20 GAGE, 18 GAGE RESPECTIVELY) -FY = 33KSI.
3. ALL WELDING OF LIGHT GAGE STEEL FRAMING MUST BE DONE BY CERTIFIED WELDERS IN ACCORDANCE WITH AWS D1.3, SPECIFICATION FOR
WELDING SHEET STEEL IN STRUCTURES.
4. MAKE CONNECTIONS WITH SELF-TAPPING SCREWS OR WELDING SO THAT THE CONNECTIONS MEET OR EXCEED THE DESIGN LOADS. ALWAYS
USE WELDS WHERE SHOWN ON DRAWINGS.
5. CUT ALL LIGHT GAGE STEEL FRAMING MEMBERS WITH SAWS OR SHEARS. FLAME CUTTING IS NOT PERMITTED.
6. THE LIGHT GAGE STEEL FRAMING SUPPLIER AND ERECTOR SHALL HAVE A MINIMUM 5 YEARS EXPERIENCE IN THE FABRICATION AND ERECTION
OF LIGHT GAGE STEEL FRAMING SYSTEMS.
7. THE CONTRACTOR SHALL DELIVER TO THE ENGINEER, AT THE END OF THE JOB, ONE (1) ELECTRONIC VERSION OF THE FINAL FIELD COPIES OF
ALL TRUSS LAYOUT SHOP DRAWINGS.
SS
ROC
PROFE
.
AI GNNIOLAE RER
SASTATE OF
860325
NNID
No.
A ENI
R
M
I
ED
EG
N
TSE
Y MOC
DE
c
SHEET TITLE
SHEET NUMBER
RATIO
101 South Pennsylvania Street
Indianapolis, Indiana 46204
317-633-4040
Architect
McComas/O'Donnell & Naccarato
Structural Engineer
1717 E. 116th Street, Suite 200
Carmel, Indiana 46032
317-580-0402
KEY PLAN
B
A
HOTEL
PROJECT NO.
SHEET ISSUE
SEAL | DATE
COPYRIGHT NOTICE: THIS ARCHITECTURAL
AND ENGINEERING DRAWING IS GIVEN IN
CONFIDENCE AND SHALL BE USED ONLY
PURSUANT TO THE AGREEMENT WITH RATIO.
NO OTHER USE, DISSEMINATION OR
DUPLICATION MAY BE MADE WITHOUT PRIOR
WRITTEN CONSENT OF RATIO. ALL COMMON
LAW RIGHTS OF COPYRIGHT AND OTHERWISE
ARE HEREBY SPECIFICALLY RESERVED.
TRAINING
CENTER
THESE ARE PROGRESS DRAWINGS, THEREFORE THEY ARE
ISSUED PRIOR TO COMPLETION OF THE STRUCTURAL DESIGN
AND OTHER DESIGN DISCIPLINES INCLUDING BUT NOT
LIMITED TO ARCHITECTURAL OR MECHANICAL DESIGNS; AND
AS SUCH, ARE INCOMPLETE BY NATURE FOR THE
COMPREHENSIVE SCOPE OF THE PROJECT. ALLOWANCES FOR
STRUCTURAL ELEMENTS REQUIRED DUE TO THE COMPLETION
AND CROSS-COORDINATION OF ALL OTHER DISCIPLINES
SHOULD BE MADE.
1717 EAST 116TH STREET | SUITE 200 | CARMEL, IN. 46032
(317) 580-0402 | WWW.O-N.com | Project No. 7167.0014.00
SHELL & CORE PERMIT SET
10/15/2021
Mechanical / Plumbing Design/Builder
Civil Engineer
DEEM LLC
6831 E 32nd Street
Indianapolis, Indiana 46226
Kimley Horn
250 East 96th Street, Suite 580
Indianapolis, Indiana 46240
Electrical Design/Builder
Barth Electric Co., Inc.
1934 N. Illinois Street
Indianapolis, Indiana 46202
Kite Realty Group
30 S. Meridian Street, #1100
Indianapolis, Indiana 46204
Owner
Republic Airways Holdings
8909 Purdue Road, Suite 300
Indianapolis, Indiana 46268
10/15/2021 2:14:39 PMS-200
GENERAL NOTES
0-N 7167.0014.00
Republic Airways
Hotel
12197 N Meridian St.
Carmel, IN 46032
1 DESIGN DEVELOPMENT 10/01/21
2 SHELL & CORE PERMIT SET 10/15/21
10/15/21
10/19/22