Loading...
HomeMy WebLinkAboutS-201 - SCHEDULESDESIGN LOAD SCHEDULE COMPONENT AREACONCRETE SLAB STEEL & JOIST CEILING COLLATERAL PODIUM/3RD FLRSLAB ON GRADETOTAL DEAD LOAD TOTAL LIVE LOAD TOTAL LOAD (ALL LOADS SHOWN ARE IN POUNDS PER SQ. FT.) 50 325 12 35050 150 100 390 40 TYPICAL FLOORROOF5 3 3 7 7 8090 40 110 30 5 1/2" CONC SLAB 65 65 BUILT IN WALLS 1010 130 3 MEZZANINE6 3 14 80 150 230BRIDGE FLOOR6 15 12 90 100 190 3" NW CONC ON 3" METAL DECK ROOF & INSULATION 5 5757 LATERAL LOAD DESIGN SCHEDULE SNOW DESIGN LOAD SCHEDULE INTERNATIONAL BUILDING CODE 2012/ASCE 7-10 WIND LOAD SEISMIC LOAD INTERNATIONAL BUILDING CODE 2012/ASCE 7-10 1.0 TABLE 7.3-2tCTHERMAL FACTOR SECTIONSEISMIC BASE SHEAR 12.8.1 SECTION II TABLE 1.5-1 SECTION 1609.4.3 FIGURE 1609.3 B 1.0 115 - V TABLE 12.2-1 12.2-1 TABLE TABLE 12.2-1 20.3-1 TABLE SECTIO N 11.6 TABLE 1604.5 SECTION 1613.2.4 1613.2.40.158 0.131 B D Cd R - - - - SD1 SDS DEFLECTION AMPLIFICATION FACTOR RESPONSE MODIFICATION COEFFICIENT SEISMIC FORCE-RESISTING SYSTEM SITE CLASSIFICATION SEISMIC DESIGN CATEGORY RISK CATEGORY (1) SECOND PERIOD SPECTRAL ACCELERATION SHORT PERIOD SPECTRAL ACCELERATION REFERENCEVALUE SYMBOL ITEM WIND EXPOSURE CATEGORY RISK CATEGORY BASIC WIND SPEED (3 SEC. GUST) REFERENCEVALUESYMBOL ITEM P g P f eC IMPORTANCE FACTOR SNOW LOAD 1.0 TABLE 1.5-2 TABLE 7.3-1 SECTION 7.3 FIGURE 1608.2 1.0 20 20 I SNOW EXPOSURE FACTOR FLAT-ROOF SNOW LOAD GROUND SNOW LOAD REFERENCEVALUESYMBOL ITEM s TABLE 1.5-2IMPORTANCE FACTOR IE ANALYSIS PROCEDURE EQUIVALENT LATERAL FORCE PROCEDURE SECTION 12.8 V 661k 1.0 * ** - ' * ' INDICATES LIGHT-FRAME (COLD FORMED STEEL) WALL SYSTEMS USING FLAT STRAP BRACING -(3RD-ROOF) ' ** ' INDICATES ORDINARY REINFORCED COCNRETE MOMENT FRAMES -(GROUND -3RD) 4 3 3 1/2 2 1/2 CONCRETE/STEEL LINTEL SCHEDULE (NON- BEARING WALLS) WIDTH OF OPENING UP TO 2'-11" 3'-0" TO 3'-11" 6'-0" TO 8'-0" (1) #4 TOP & BOTTOMž3 1/2x3 1/2x5/16 ž4x3 1/2x5/16 (1) #4 TOP & BOTTOM (1) #5 TOP & BOTTOM STEEL FOR EACH 4" OF WALL THICKNESS REMARKSREINF. CONC. FOR EACH 4" OF WALL THICKNESS ž6x3 1/2x5/16 NOTES: 1) ALL CONCRETE LINTELS SHALL BE 4000 PSI CONCRETE AT 28 DAYS WITH GRADE 60 REINFORCING 2) ALL STEEL LINTELS SHALL BE ASTM A-36. 3) FILL CMU VOIDS SOLID (2) COURSES BELOW LINTEL BEARING. 4) ALL LINTELS SHALL HAVE 8" MINIMUM BEARING U.N.O. 5) ALL CONCRETE LINTELS SHALL BE 8" DEEP, U.N.O. 4'-0" TO 5'-11" ž5x3 1/2x5/16 (1) #4 TOP & BOTTOM 8'-1" TO 10'-0" (1) #5 TOP & BOTTOMž6x3 1/2x3/8 TYPICAL HEADER DETAIL METAL STUD HEADER SCHEDULE 6T18 (TOP & BOTT.) SEE SCHED. FOR SIZE KICKERS REQ'D @ 4'-0" o/c KICKERS REQ'D @ 4'-0" o/c @ 4'-0" o/c KICKERS REQ'D N.R. N.R. (2) STUD (2) STUD (2) STUD (2) STUD (2) 14J12 16'-0" TO ABOVE (2) 10SW14 10'-0" TO 12'-0" (2) 12SW12 JAMB STUDS BRACINGMETAL STUD LINTEL SIZE (2) 8SW14 (2) 6SW16 (2) STUD 12'-0" TO 16'-0" 7'-0" TO 10'-0" UP TO 7'-0" WIDTH OF OPENING (NON- BEARING WALLS) LIGHT GAUGE BEARING WALL SCHEDULE LEVEL 7TH TO ROOF 6TH TO 7TH INTERIOR WALL NON LOAD BEARING EXTERIOR WALL INTERIOR JAMB NOTES: 1) ALL STUD JOISTS AND ACCESSORIES SHALL BE Fy=50 KSI 2) BOTTOM TRACK SHALL BE HOT-DIPPED GALVANIZED (G60) 3) BRIDGING REQUIRED @ 4'-0" o/c FOR ALL WALL STUDS. 5TH TO 6TH EXTERIOR JAMB 600S200-43 (6J18) @ 24" o/c 600S200-54 (6J16) @ 16” o/c 600S250-68 (6JE14) @ 16” o/c (2) STUD (3) STUD (3) STUD 600S200-43 @ 16" o/c 600S200-43 @ 16" o/c 600S200-54 (50) @ 16" o/c (2) STUD (3) STUD (3) STUD 4TH TO 5TH (3) STUD (3) STUD 3RD TO 4TH (3) STUD (3) STUD 600S250-68 (6JE14) @ 12” o/c 600S200-54 (50) @ 16" o/c 600S250-97 (6JE12) @ 12” o/c 600S200-54 (50) @ 16" o/c TYPICAL ELEVATION w/ CENTER BOUNDARY ELEMENT (XB2) TYPICAL ELEVATION w/o CENTER BOUNDARY ELEMENT (XB1) 3RD FLOOR 4TH FLOOR 5TH FLOOR 6TH FLOOR WALL LENGTH PER ARCH. DRAWINGS 14" TO B.E. ® 14" TO B.E. ® WALL LENGTH PER ARCH. DRAWINGS 14" TO B.E. ® 14" TO B.E. ® BOUNDARY ELEMENT (SEE SCHEDULE) CENTER POST (SEE SCHEDULE) STRAP BRACE (SEE SCHEDULE) BOUNDARY ELEMENT (SEE SCHEDULE) BOUNDARY ELEMENT (SEE SCHEDULE) STRAP BRACE (SEE SCHEDULE) BOUNDARY ELEMENT (SEE SCHEDULE) FLAT STRAP BRACE SCHEDULE BRACE MARK BOUNDARY ELEMENT XB2 XB1 7TH TO ROOF& 6TH TO 7THCENTER POST STRAP STRAP FORCE BOUNDARY ELEMENT 5TH TO 6TH& 4TH TO 5THCENTER POST STRAP STRAP FORCE (2) 600S200-54 (50 KSI) NOTES: 1. (2) STRAPS INDICATES FLAT STRAP X-BRACE TO BE PROVIDED ON BOTH SIDES OF THE METAL STUD WALL. 2. STRAP FORCE INDICATED IS THE SERVICE LEVEL AXIAL TENSION IN THE FLAT STRAP MEMBER IN KIPS. TBD - SEE 4/S-403 TBD - SEE 4/S-403 (2) 43 MILx10" Fy=50 KSI ROOF 7TH FLOOR ROOF 3RD FLOOR 4TH FLOOR 5TH FLOOR 6TH FLOOR 7TH FLOOR BOUNDARY ELEMENT 3RD TO 4THCENTER POST STRAP STRAP FORCE (2) 600S200-54 (50 KSI) 17.3K (4) 600S250-68 (50 KSI) (2) 54 MILx10" Fy=50 KSI (2) 600S200-68 (50 KSI) 28.4K (4) 600S250-97 (50 KSI) (2) 68 MILx10" Fy=50 KSI (2) 600S250-97 (50 KSI) 29.6K (2) 600S200-54 (50 KSI) (2) 43 MILx10" Fy=50 KSI 14.6K (4) 600S250-68 (50 KSI) (2) 54 MILx10" Fy=50 KSI 25.6K (4) 600S250-97 (50 KSI) (2) 68 MILx10" Fy=50 KSI 26.1K METAL STUD BEAM SCHEDULE END POSTMETAL STUD SIZE 5'-0" TO 8'-0" UP TO 5'-0" SPAN (2) 600S162-97 (50) (62W12) (2) 600S162-68 (50) (6SW14) (2) 1000S250-118 (50) (10JE10) (2) 800S250-68 (50) (8JE14) CONCRETE COLUMN SCHEDULE MARK LEVEL FND - 3rd C1 C2 C3 C4 28"x28" (12) #8 #4 @ 12" 28"x28". (16) #10 32"x32" (12) #9 12"x28" L Shaped (12) #8 NOTES: 1) f'c FOR ALL COLUMNS IS 6000 psi (U.N.O.). 2) DIMENSIONS & TIE SPACING INDICATED IN INCHES. 3) TIES TO BE PER TYPICAL DETAIL U.N.O. VERT. REINF. SIZE TIES #4 @ 12" #4 @ 12" #4 @ 12" C7 32" DIA. (12) #8 #4 @ 12" C8 28" DIA. (12) #8 #4 @ 12" C9 28" DIA. (12) #10 #4 @ 12" SEE SCH. FOR SPLICE WELDING DIAGONAL GALV. STL. STRAPPING (45° < 0 < 60°) PROVIDE STRAPPING PER SCHEDULE IN OPPOSITE DIRECTIONS (SCREW STRAPPING TO EA. STUD) CONT. BRIDGING STUD SPC. SEE PLAN STRAP BRACING SCHEDULE 4" x 14 GA. SIZE & GAUGEMETAL STRAP X-BRACE FILLET MIN. WELD LENGTH @ GUSSET PLATES LENGTH @ SPLICE IN STRAP BRACING MIN. GROOVE WELD DBL. STUD MIN. @ GUSSET LOCATION TYP. STRAPPING SIZE 14 GA. GUSSET PL. MIN. SEE SCHED. FOR SEE SCH. TRACK 6" x 14 GA. 5" EA. SIDE 7" EA. SIDE 8" EA. SIDE 6" EA. SIDE BASED ON: 14 GAGE, Fy=50 ksi. TYPICAL DETAIL @ DIAGONAL STRAP LATERAL BRACING 2RD - ROOF FND. - 3RD (2) 362S200-68 VERT. STUDS @ GUSSET (3) 362S200-68 CONT. 14 GA. TRACK w/ 1/2"Ø EXP. ANCHORS @ 32" o/c (2) S/HDU6 w/ (12) #14 SCREWS INTO VERT. STUD & 5/8"Ø A.B. w/ NUT, 12" MIN. EMBED. (BY SIMPSON STRONG-TIE) (TYP.) SS ROC PROFE.AI GNNIOLAE RER SASTATE OF 860325 NNID No. A ENI R M I ED EG N TSE Y MOC DE c SHEET TITLE SHEET NUMBER RATIO 101 South Pennsylvania Street Indianapolis, Indiana 46204 317-633-4040 Architect McComas/O'Donnell & Naccarato Structural Engineer 1717 E. 116th Street, Suite 200 Carmel, Indiana 46032 317-580-0402 PROJECT NO. SHEET ISSUE SEAL | DATE COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE, DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED. THESE ARE PROGRESS DRAWINGS, THEREFORE THEY ARE ISSUED PRIOR TO COMPLETION OF THE STRUCTURAL DESIGN AND OTHER DESIGN DISCIPLINES INCLUDING BUT NOT LIMITED TO ARCHITECTURAL OR MECHANICAL DESIGNS; AND AS SUCH, ARE INCOMPLETE BY NATURE FOR THE COMPREHENSIVE SCOPE OF THE PROJECT. ALLOWANCES FOR STRUCTURAL ELEMENTS REQUIRED DUE TO THE COMPLETION AND CROSS-COORDINATION OF ALL OTHER DISCIPLINES SHOULD BE MADE. 1717 EAST 116TH STREET | SUITE 200 | CARMEL, IN. 46032 (317) 580-0402 | WWW.O-N.com | Project No. 7167.0014.00 SHELL & CORE PERMIT SET 10/15/2021 Mechanical / Plumbing Design/Builder Civil Engineer DEEM LLC 6831 E 32nd Street Indianapolis, Indiana 46226 Kimley Horn 250 East 96th Street, Suite 580 Indianapolis, Indiana 46240 Electrical Design/Builder Barth Electric Co., Inc. 1934 N. Illinois Street Indianapolis, Indiana 46202 Kite Realty Group 30 S. Meridian Street, #1100 Indianapolis, Indiana 46204 Owner Republic Airways Holdings 8909 Purdue Road, Suite 300 Indianapolis, Indiana 46268 10/15/2021 2:14:41 PMS-201 SCHEDULES 0-N 7167.0014.00 Republic Airways Hotel 12197 N Meridian St. Carmel, IN 46032 STEEL COLUMN SCHEDULE MARK SIZE BASE PLATE ANCHOR RODS REMARKS C5 W12x53 1x20x1'-8" (4) 3/4"Ø C6 W18x130 1 1/2x20x2'-4" (4) 1"Ø WALL FOOTING SCHEDULE MARK DIMENSIONS REINFORCINGWIDTH DEPTH F30.20 3'-0" 1'-8" (5) #5 LWB #4@24 SWB COLUMN FOOTING SCHEDULE MARK DIMENSIONS REINFORCINGLENGTH WIDTH THICKNESS F50 5'-0" 5'-0" 1'-8" (5) #6 EWB F70 7'-0" 7'-0" 1'-10" (8) #6 EWB F96 9'-6" 9'-6" 2'-4" (10) #7 EWB F110 11'-0" 11'-0" 2'-8" (10) #8 EWB F120 12'-0" 12'-0" 2'-10" (9) #9 EWB F130 13'-0" 13'-0" 3'-2" (11) #9 EWB F146 14'-6" 14'-6" 3'-4" (13) #9 EWB F156 15'-6" 15'-6" 3'-6" (15) #9 EWB F100180 18'-0" 10'-0" 3'-10" (10) #9 LWB, (18) #9 SWB HANGER SCHEDULE MARK SIZE HA1 HSS5X5X5/16 POST UP SCHEDULE MARK SIZE Base Plate Anchor Rods Remarks PU1 HSS4x4x3/8 3/4x12x1'-0" (4) 3/4"Ø PU2 HSS6x6x3/8 3/4x12x1'-0" (4) 3/4"Ø OFFSET BASE PLATE w/ EXP. ANCHORS PU3 HSS5X5X5/16 3/4x12x1'-0" (4) 3/4"Ø SCALE: 3/4" = 1'-0" METAL STUD 1 DESIGN DEVELOPMENT 10/01/21 2 SHELL & CORE PERMIT SET 10/15/21 10/15/21 10/19/22