HomeMy WebLinkAboutS-301-FOUNDATION SECTIONSSLAB ON
GRADE
P/C CONC. WALL
FIN. GRADE
(SEE CIVIL DWGS.)
BASE CONNECTION
(BY P/C MFR.)3" CLR.SEE PLAN/SCHEDULE
FOR FOOTING SIZE,
REINF. & EL.
MANUFACTURER
PER PRECAST
SLAB
CONCRETE
P/C COLUMN
ENCASE w/ 3000 psi
CONCRETE MINIMUM
BASE CONNECTION
FOOTING SIZE, REINF. & EL.
SEE PLAN/SCHEDULE FOR
3" CLR. 3"
3"
ISOLATION JOINT
PLANSEE8" CONC. w/
#4 @ 12" E.W.
FIN. FLR. EL.
(SEE PLAN)
2'-0"3" CLR. .SEE PLAN/SCHEDULE FOR
FOOTING SIZE, REINF. & EL.
® WALL & FOOTING
SEE PLAN FOR
SLAB THICKNESS
PMF
#4 CONT.
#4 DOWELS @ 18" o/c
2'-0
2'-0SLAB ON
GRADE
P/C CONC. WALL
FIN. GRADE
(SEE CIVIL DWGS.)
BASE CONNECTION
(BY P/C MFR.)3" CLR.SEE PLAN/SCHEDULE
FOR FOOTING SIZE,
REINF. & EL.
CURTAINWALL
(SEE ARCH.)
HSS 3x3x1/4 CONT.
HSS 3x3x1/4 @ CURTAINWALL
CORNER - MAX 9'-0" OC
2.5k 6.5k
4.0k
2.0k (WIND)
10" CONC. w/
#4 @ 12" E.W.
FIN. FLR. EL.
(SEE PLAN)
2'-0"
FIN. GRADE 3" CLR.3'-0" (MIN.).
SEE PLAN/SCHEDULE FOR
FOOTING SIZE, REINF. & EL.
® WALL & FOOTING
P/C CONC. WALL
BASE CONNECTION
(BY P/C MFR.)3" CLR.SEE PLAN/SCHEDULE
FOR FOOTING SIZE,
REINF. & EL.
SEE PLAN FOR
SLAB THICKNESS
PMF
SEE PLAN FOR
SLAB THICKNESS
PMF
SLAB ON
GRADE
P/C CONC. WALL
BASE CONNECTION
(BY P/C MFR.)3" CLR.SEE PLAN/SCHEDULE
FOR FOOTING SIZE,
REINF. & EL.
SEE PLAN FOR
SLAB THICKNESS
PMF
PMF
SS
ROC
PROFE.AI GNNIOLAE RER
SASTATE OF
860325
NNID
No.
A ENI
R
M
IED
EG
N
TSE
Y MOC
DE
c
SHEET TITLE
SHEET NUMBER
RATIO
101 South Pennsylvania Street
Indianapolis, Indiana 46204
317-633-4040
Architect
McComas/O'Donnell & Naccarato
Structural Engineer
Civil Engineer
Mechanical / Plumbing Design/Builder
1717 E. 116th Street, Suite 200
Carmel, Indiana 46032
317-580-0402
Kimley Horn
250 East 96th Street, Suite 580
Indianapolis, Indiana 46240
DEEM LLC
6831 E 32nd Street
Indianapolis, Indiana 46226
KEY PLAN
B
A
HOTEL
PROJECT NO.
SHEET ISSUE
SEAL | DATE
COPYRIGHT NOTICE: THIS ARCHITECTURAL
AND ENGINEERING DRAWING IS GIVEN IN
CONFIDENCE AND SHALL BE USED ONLY
PURSUANT TO THE AGREEMENT WITH RATIO.
NO OTHER USE, DISSEMINATION OR
DUPLICATION MAY BE MADE WITHOUT PRIOR
WRITTEN CONSENT OF RATIO. ALL COMMON
LAW RIGHTS OF COPYRIGHT AND OTHERWISE
ARE HEREBY SPECIFICALLY RESERVED.
TRAINING
CENTER
**-ALL DRAWINGS MARKED AS PART OF AN "EARLY"
SUBMISSION PACKAGE ARE ISSUED PRIOR TO COMPLETION OF
OTHER DESIGN DISCIPLINES INCLUDING BUT NOT LIMITED TO
ARCHITECTURAL OR MECHANICAL DESIGNS; AND AS SUCH,
ARE INCOMPLETE BY NATURE FOR THE COMPREHENSIVE
SCOPE OF THE PROJECT. ALLOWANCES FOR STRUCTURAL
ELEMENTS REQUIRED DUE TO THE COMPLETION AND
CROSS-COORDINATION OF ALL OTHER DISCIPLINES SHOULD
BE MADE.
1717 EAST 116TH STREET | SUITE 200 | CARMEL, IN. 46032
(317) 580-0402 | WWW.O-N.com | Project No. 7167.0013.00
SHELL & CORE PERMIT SET
10/15/21
Electrical Design/Builder
Barth Electric Co., Inc.
1934 N. Illinois Street
Indianapolis, Indiana 46202
10/15/2021 2:23:25 PMS-301
FOUNDATION
SECTIONS
21040.000
Republic Airways
Training Center
12195 N. Meridian St.
Carmel, Indiana
46032
Section
S-301
1 Section
S-301
2 Section
S-301
3
Section
S-301
4
Section
S-301
5 Section
S-301
6 Section
S-301
7
1 DESIGN DEVELOPMENT 10/01/21
2 CONSTRUCTION DOCUMENTS 10/15/21
10/15/21
10/19/22