HomeMy WebLinkAboutS-401-TYPICAL FRAMING DETAILS* LAP SPLICELENGTH 6"MIN. (TYP.)AS PER SCHEDULE (TYP.)LAP SPLICE* FOR SIZE AND NUMBER OF REINF. BARS AT END OF WALL, SEE PLAN/SCHEDULE. (SEE PLANS IF INTEGRAL PIERS EXIST, 'MP' ON PLANS) VERTICAL REINFORCEMENT PRE-FORMED "TEE" JOINT REINFORCING TYPICAL WALL SECTION 1'-6"1'-6"VERTICAL REINFORCEMENT (2) #5 HOOKS INTO INTERSECTING WALL USE PREFABRICATED BLOCK OR CUT OUT FACE SHELL TO ALLOW PLACEMENT OF REINFORCING BARS AND GROUT. HOOK PER SCHEDULE OF LAP SPLICE TO BARS IN EACH WALL SECTION AT BOND BEAM NOTES: 1) SIZE OF HORIZONTAL INTERSECTION REINFORCING BARS TO MATCH BOND BEAM REINFORCING. 2) NORMAL JOINT AND BOND BEAM REINFORCING NOT SHOWN FOR CLARITY. 3) VERTICAL REINFORCING BARS TO EXTEND CONTINUOUSLY THROUGH BOND BEAMS. LAP VERTICALS AS PER SCHEDULE ABOVE BOND BEAMS. TYPICAL HORIZONTAL CMU WALL INTERSECTION REINFORCEMENT DETAIL TYPICAL WALL SECTION *LAP SPLICELENGTH 6"MIN. (TYP.)VERTICAL REINFORCEMENT * FOR SIZE AND NUMBER OF REINF. BARS AT END OF WALL, SEE PLAN/SCHEDULE. (SEE PLANS IF INTEGRAL PIERS EXIST, 'MP' ON PLANS) PRE-FORMED CORNER JOINT REINFORCING USE PREFABRICATED BLOCK OR CUT OUT FACE SHELL TO ALLOW PLACEMENT OF REINFORCING BARS AND GROUT. HOOK PER SCHEDULE OF LAP SPLICE TO BARS IN EACH WALL SECTION AT BOND BEAM NOTES: 1) PROVIDE VERTICAL STEEL REINFORCING BAR SIZE AS NOTED ON PLAN, IN SECTION, OR IN GENERAL NOTES TO MATCH ADJACENT VERTICAL BARS. 2) SIZE OF HORIZONTAL CORNER REINFORCING BARS TO MATCH BOND BEAM REINFORCING. 3) BOND BEAM REINFORCING NOT SHOWN FOR CLARITY. 4) VERTICAL REINFORCING BARS TO EXTEND CONTINUOUSLY THROUGH BOND BEAMS. LAP VERTICALS AS PER SCHEDULE ABOVE BOND BEAMS.1'-6"1'-6"VERTICAL REINFORCEMENT TYPICAL HORIZONTAL CMU WALL CORNER REINFORCEMENT DETAIL (END OF WALL DETAIL SIMILAR) TYPICAL SECTION @ INTERIOR SLAB EDGE EDGE CLOSURE CHARTSLAB DEPTH, "D"DECK CAN BEPARALLEL ORPERP. TO BEAM CONT. 16 GA. CLOSURE, MIN. SEE ARCH. SEE ARCH. 1/2" JOIST TOP CHORD EXTENSION 2" MIN. OVERHANG, "L" CONT. CLOSURE, SEE CHART NOTES: 1) GAGE ™ OR BENT ™ PER CHART FOR SPECIFIC CONDITION. 2) AT LOCATIONS WHERE ITEMS (RAILING POST, METAL STUD, ETC.) ARE CONNECTED TO VERTICAL FACE OF CLOSURE ™, PROVIDE MIN. 1/4" BENT ™ w/ 1/2"Øx6" HEADED STUD @ 24" o/c. G.C. TO COORDINATE LOCATIONS. 3) PROVIDE AT ALL INTERIOR SLAB EDGES, U.N.O. 4) SEE SPECIFIC SECTIONS FOR ADDITIONAL REQUIREMENTS. ¦ 3" OVERHANG "L"SLAB DEPTH "D" ¦ 4" 4" < D ¦ 6" 6" < D ¦ 9" 9" < D ¦ 10 1/2" 10 1/2" < D ¦ 12" 16 GA. 16 GA. 12 GA. 10 GA. 10 GA. 3" < L ¦ 5" 14 GA. 14 GA. 10 GA. 10 GA. 10 GA. 5" < L ¦ 9" 10 GA. 10 GA. 10 GA. 1/4" 1/4" 9" < L ¦ 12" 1/4" 1/4" 1/4" 1/4" 1/4" 12" < L ¦ 15" 1/4" 1/4" 1/4" 1/4" 5/16" 15" < L ¦ 18" 5/16" 5/16" 3/8" 3/8" 3/8" 6 3/4 " 2" 3" 1 0 1 5/ 16" 1/ 2" TYPICAL FLOOR OPENING REINFORCING DETAIL 1'-0" MIN. UP TO 5'-0" OPNG. 5'-0" TO 7'-0" OPNG. 1'-0"1'-0"CONTRACTOR TO ENSURE PROPER CONCRETE COVERAGE BELOW REINFORCING ANY LOCATION (2) #4 @ UP TO 5'-0" LG. OPNG. ((4) #4 FOR 5'-0" TO 7'-0" LG. OPNG.) (2) #5 (2) #5 (3) #5 (3) #5 FOR OPENINGS LONGER THAN 7'-0" (PERPENDICULAR TO DECK SPAN) NOTIFY ENGINEER.3/4"PLACE REBAR IN REINFORCING BEYOND CLR.FIRST FLUTE ADJACENT TO OPENING. (COMPOSITE CONSTRUCTION)® BM. ®® BM.VARIESANYWIDTHVARIESNOTE:DECK SPANBLOCK OUT OPENING AS REQUIRED. DO NOT FIELD CUT DECK OPNG. UNTIL CONCRETE HAS CURED. #4 x 2'-0" @ EA. CORNER (TYP.)1 ' -2 11 /1 6" 9 5/1 6" 1 '-2" 3 ' - 2 " 3 ' - 2 " 1 ' - 6 1 / 2 " 1 ' -0 1/ 4" 2 1 / 1 6 " 2 7/ 1 6 " 2 1/ 4 " 6 1 5/ 16"7 9/1 6" 2 1/ 2"2' -8 1 /8"2 1 /2"2 1/ 2" 2' -8 1 /8" 2 1 /2" 2 1/ 2" 2' -8 1 /8" 2 1 /2" TYPICAL LINTEL/BEAM BEARING DETAILS WIDE-FLANGE LINTEL/BEAM BEARINGANGLE LINTEL BEARING 3/8" NEOPRENE BEARING PAD CONCRETE-FILLED CMU (2) COURSES BELOW BEARING LINTEL- SEE PLAN/ SCHEDULE FOR ANGLE SIZE BEARING PLATE w/ MIN. (2) HEADED STUDS IN GROUTED CORES (SEE SCHEDULE) CONCRETE-FILLED CMU (2) COURSES BELOW BEARING EXTEND BEAM FOR FULL LENGTH OF BRG. PLATE (60 DUROMETERS) 8" BEARING U.N.O. 8" (MIN.) SEE PLAN/ SIZE SCHEDULE FOR LINTEL/BEAM- (AT CMU BEARING WALLS) 8" 8" 1/4 4" ONE END OF BEAM ONLY PROVIDE (2) 3/4"Ø RODS WELDED TO BEARING PLATE, CTRD. IN STANDARD SLOTTED HOLES IN BOTTOM FLANGE (PARALLEL TO BEAM SPAN), AT NON-WELDED END A4" 2" 2"(4" @ ELEV. SEPARATOR BEAM) WALL MAY CONTINUE ABOVE ENCASE BEAM IN MASONRY 3/4" NON-SHRINK GROUT (2) 3/4"Ø ANCHOR BOLTS 16" 3" ® OF WALL U.N.O. GROUT SOLID A MIN. AREA OF 16" LONG, 24" DEEP DIRECTLY BELOW BEAM BRG. ™ 1/2x4x0'-10" (ALSO ACTS AS LEVELING ™) BEAM BEARING AT 2" 4" Section A - 1/4 3TYP.1 1/2"COLUMN BASE PLATE DETAIL X (TYP.) X (TYP.) (USE ONLY AT COLUMNS INDICATED) ANCHOR ROD (TYP.) COLUMN BASE ™ A BASE ™ COLUMN (TYP.) ANCHOR ROD B COLUMN MARK WELD SIZE (IN.) A BX (TYP.)X (TYP.)ANCH. ROD DIA. 3/4" 1 1/2" DIMENSION "X" ®®®®MIN. PLATE WASHER THICK. SIZE 1/4" 2" STOP WELD @ TOES OF FLGS. 3" 3 " 3 " 3 " C1, PU1 5/16" TYPICAL BEAM OVER HSS COLUMN CONNECTION STIFF. ™'s (BOTH SIDES) (THICKNESS TO MATCH COL. FLANGE THICKNESS) TYP. MIN. 3/4" ™ w/ (4) 3/4"Ø BOLTS . TYPICAL BOLTED BEAM TO COLUMN FLANGE GRAVITY MOMENT CONNECTION "k" SHIM (IF REQ'D), 1/4" MAX. THK. PERMITTED FLANGE BOLTS STIFFENER ™'s, WIDTH & THICKNESS TO MATCH FLANGE ™'s FLANGE ™'s (T&B) TYP. SHEAR CONNECTION TYP. NOTES: 1) DETAILS SHOWN ARE NOT FULLY DESIGNED AND DETAILED AND ARE CONCEPTUAL IN NATURE. STEEL FABRICATOR'S ENGINEER TO FULLY DESIGN AND DETAIL MOMENT CONNECTIONS FOR FORCES SHOWN ON PLAN. THIS INCLUDES FLANGE PLATES, BOLTS AND WELDS. (IF NO FORCE IS SHOWN, DESIGN FOR FULL CAPACITY OF BEAM). 2) WELDS CAN BE SUBSTITUTED FOR BOLTS. 3) BOLTS SHALL BE ASTM A325/A490-SC, WITH STANDARD SIZE HOLES IN BEAM. 4) STEEL FABRICATOR TO PROVIDE DECK SUPPORT AS REQUIRED. 7/8" TYPICAL BEAM TO GIRDER MOMENT CONNECTION - FIELD BOLTED BEAMS DIFFERENT DEPTHS BEAMS SAME DEPTHS FLANGE ™'s (T&B) SHEAR CONNECTIONSHIM (IF REQ'D), 1/4" MAX. THK. PERMITTED SUPPORTED BEAM SUPPORTING GIRDER (BEAM) NOTES: 1) DETAILS SHOWN ARE NOT FULLY DESIGNED AND DETAILED AND ARE CONCEPTUAL IN NATURE. STEEL FABRICATOR'S ENGINEER TO FULLY DESIGN AND DETAIL MOMENT CONNECTIONS FOR FORCES SHOWN ON PLAN. THIS INCLUDES FLANGE PLATES, BOLTS AND WELDS. (IF NO FORCE IS SHOWN, DESIGN FOR FULL CAPACITY OF BEAM). 2) WELDS CAN BE SUBSTITUTED FOR BOLTS. 3) BOLTS SHALL BE ASTM A325/A490-SC, WITH STANDARD SIZE HOLES IN BEAM. 4) STEEL FABRICATOR TO PROVIDE DECK SUPPORT AS REQUIRED. .. TENSION DEVELOPMENT AND LAP SPLICE LENGTH (FOR MASONRY ONLY) BAR PLACEMENTCMU THICKNESS 8" #3 CENTER BAR SIZE EDGE #4 #5 #6 #7 #8 #9 12 12 12 21 19 33 37 64 51 79 79 105 102 NP MASONRY DESIGN STRENGTH f'm = 2000 psi 12" #3 #4 #5 #6 #7 #8 #9 12 12 12 21 12 33 23 64 32 79 49 105 63 118 NOTES: 1) ALL LENGTHS ARE IN INCHES. 2) FOR BAR PLACEMENT, EDGE DISTANCE: "CENTER" INDICATES CENTER OF BAR ALIGNS WITH CENTER OF BLOCK THICKNESS. "EDGE" INDICATES CENTER OF BAR TO OUTSIDE FACE OF BLOCK IS AS FOLLOWS: #3-#6 - 2.375" #7 - 2.625" #8 - 3.0" #9 - 3.375" 3) WHERE (2) BARS PER CELL OCCUR THEY SHALL BE PLACED PER EDGE CONDITION, SEE NOTE #2. 4) 6" CMU (2) BARS PER CELL IS NOT PERMITTED. 8" CMU (2) BARS PER CELL UP TO #5 ARE PERMITTED. 10" CMU (2) BARS PER CELL UP TO #7 ARE PERMITTED. 5) "NP" INDICATES NOT PERMITTED. 6) #10 AND #11 BARS WHERE SHOWN ON PLAN OR DETAILS REQUIRE A MECHANICAL SPLICE. 7) FOR EPOXY-COATED BARS INCREASE LENGTHS SHOWN BY 50%. TYPICAL WF COLUMN CONNECTION TO TRANSFER GIRDER COLUMN WEB PARALLEL TO GIRDER WEBCOLUMN WEB PERPENDICULAR TO GIRDER WEB 1" TYP. COLUMN 3/4" BASE ™ w/ (4) BOLTS 1 1/2" MIN. BASE ™ w/ (4) BOLTS FITTED STIFF. ™, BOTH SIDES TRANSFER GIRDER NOTE: 1) STIFFENER ™ THICKNESS TO MATCH COLUMN FLANGE THICKNESS. FITTED STIFF. ™, BOTH SIDES TRANSFER GIRDER 0" COLUMN SS ROC PROFE . AI GNNIOLAE RER SASTATE OF 860325 NNID No. A ENI R M IED EG N TSE Y MOC DE c SHEET TITLE SHEET NUMBER RATIO 101 South Pennsylvania Street Indianapolis, Indiana 46204 317-633-4040 Architect McComas/O'Donnell & Naccarato Structural Engineer Civil Engineer Mechanical / Plumbing Design/Builder 1717 E. 116th Street, Suite 200 Carmel, Indiana 46032 317-580-0402 Kimley Horn 250 East 96th Street, Suite 580 Indianapolis, Indiana 46240 DEEM LLC 6831 E 32nd Street Indianapolis, Indiana 46226 KEY PLAN B A HOTEL PROJECT NO. SHEET ISSUE SEAL | DATE COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE, DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED. TRAINING CENTER **-ALL DRAWINGS MARKED AS PART OF AN "EARLY" SUBMISSION PACKAGE ARE ISSUED PRIOR TO COMPLETION OF OTHER DESIGN DISCIPLINES INCLUDING BUT NOT LIMITED TO ARCHITECTURAL OR MECHANICAL DESIGNS; AND AS SUCH, ARE INCOMPLETE BY NATURE FOR THE COMPREHENSIVE SCOPE OF THE PROJECT. ALLOWANCES FOR STRUCTURAL ELEMENTS REQUIRED DUE TO THE COMPLETION AND CROSS-COORDINATION OF ALL OTHER DISCIPLINES SHOULD BE MADE. 1717 EAST 116TH STREET | SUITE 200 | CARMEL, IN. 46032 (317) 580-0402 | WWW.O-N.com | Project No. 7167.0013.00 SHELL & CORE PERMIT SET 10/15/21 Electrical Design/Builder Barth Electric Co., Inc. 1934 N. Illinois Street Indianapolis, Indiana 46202 10/15/2021 2:23:30 PMS-401 TYPICAL FRAMING DETAILS 21040.000 Republic Airways Training Center 12195 N. Meridian St. Carmel, Indiana 46032 1 DESIGN DEVELOPMENT 10/01/21 2 CONSTRUCTION DOCUMENTS 10/15/21 10/15/21 10/19/22