HomeMy WebLinkAboutS-402 - TYPICAL FRAMING DETAILSFIN. FLR. EL. (SEE PLAN) FIN. FLR. EL. (SEE PLAN) TYPICAL SECTION @ INTERIOR SLAB EDGE EDGE CLOSURE CHARTSLAB DEPTH, "D"DECK CAN BE PARALLEL ORPERP. TO BEAM CONT. 16 Ga. CLOSURE, MIN. SEE ARCH. SEE ARCH. 1/2" JOIST TOP CHORD EXTENSION 2" MIN. OVERHANG, "L" CONT. CLOSURE, SEE CHART NOTES: 1) GAGE ™ OR BENT ™ PER CHART FOR SPECIFIC CONDITION. 2) AT LOCATIONS WHERE ITEMS (RAILING POST, METAL STUD, ETC.) ARE CONNECTED TO VERTICAL FACE OF CLOSURE ™, PROVIDE MIN. 1/4" BENT ™ w/ 1/2"Øx6" HEADED STUD @ 24" o/c. G.C. TO COORDINATE LOCATIONS. 3) PROVIDE AT ALL INTERIOR SLAB EDGES, U.N.O. 4) SEE SPECIFIC SECTIONS FOR ADDITIONAL REQUIREMENTS. ¦ 3" OVERHANG "L"SLAB DEPTH "D" ¦ 4" 4" < D ¦ 6" 6" < D ¦ 9" 9" < D ¦ 10 1/2" 10 1/2" < D ¦ 12" 16 Ga. 16 Ga. 12 Ga. 10 Ga. 10 Ga. 3" < L ¦ 5" 14 Ga. 14 Ga. 10 Ga. 10 Ga. 10 Ga. 5" < L ¦ 9" 10 Ga. 10 Ga. 10 Ga. 1/4" 1/4" 9" < L ¦ 12" 1/4" 1/4" 1/4" 1/4" 1/4" 12" < L ¦ 15" 1/4" 1/4" 1/4" 1/4" 5/16" 15" < L ¦ 18" 5/16" 5/16" 3/8" 3/8" 3/8" 6 3/ 4" 2" 3" 10 15/16" 1/2" TYPICAL FLOOR OPENING REINFORCING DETAIL 1'-0" MIN. UP TO 5'-0" OPNG. 5'-0" TO 7'-0" OPNG. 1'-0"1'-0"CONTRACTOR TO ENSURE PROPER CONCRETE COVERAGE BELOW REINFORCING ANY LOCATION (2) #4 @ UP TO 5'-0" LG. OPNG. ((4) #4 FOR 5'-0" TO 7'-0" LG. OPNG.) (2) #5 (2) #5 (3) #5 (3) #5 FOR OPENINGS LONGER THAN 7'-0" (PERPENDICULAR TO DECK SPAN) NOTIFY ENGINEER.3/4"PLACE REBAR IN REINFORCING BEYOND CLR.FIRST FLUTE ADJACENT TO OPENING. (COMPOSITE CONSTRUCTION)® BM. ®® BM.VARIESANYWIDTHVARIESNOTE:DECK SPANBLOCK OUT OPENING AS REQUIRED. DO NOT FIELD CUT DECK OPNG. UNTIL CONCRETE HAS CURED. #4 x 2'-0" @ EA. CORNER (TYP.) 1'-2 11 / 1 6 " 9 5/16" 1'-2" 3 ' - 2 " 3 ' - 2 " 1'-6 1/2" 1'-0 1/4" 2 1/16" 2 7/ 1 6 " 2 1/ 4 " 6 15/16" 6 7/8" 2 1/2"2'-8 1/ 8"2 1/2"2 1/2" 2'-8 1/ 8" 2 1/2" 2 1/2" 2'-8 1/ 8" 2 1/2" TYPICAL METAL STUD WALL AND/OR LATERAL LOAD RESISTING WALL ELEVATION Section A - A - 1'-0" MAX. 1'-0" MAX. ROUGH OPENING WIDTH TYPICAL STUD SPACING STUD LINTEL(SEE PLAN/SCHEDULE) BUILT-UP METAL (TYP.) ROUGH OPNG.WIDTH TOP TRACK AT EXTERIOR WALLS: (2) JACK STUDS & (2) KING STUDS AT ALL LINTELS (MIN. U.N.O. ON PLAN) AT INTERIOR WALLS: (2) JACK STUDS & (1) KING STUD AT ALL LINTELS (MIN. U.N.O. ON PLAN) WHEN NOT AT TYP. STUD SPACING EXTRA DOUBLE STUD HORIZONTAL GALVANIZED STEEL STRAPPING CONT. MFR. RECOMMENDATIONS) TO DEVELOP FULL CAPACITY OF METAL STUDS. ATTACHMENTS AS PER w/TRACK BLOCKING (SIZE, SPACING AND BOTTOM TRACK CONCRETE SLAB ON METAL DECK FLOOR CONSTRUCTIONSEE PLAN METAL STUD (TYP.) OF STUD. CONNECT TO FLOOR CONSTRUCTION PER MFR. INSTALL TRACK TIGHT TO BOTTOM WELD DECK TO DISTRIBUTION HEADER SHEATHING w/ JOINTAT CENTER OF DISTRIBUTION HEADER TIEDOWN ANCHORS ALONG SHEAR WALLS OR AT SHEATHING (FOR SHEAR WALLS, SEE SCHEDULE) HSS 2xSTUD DEPTHx1/4 (MIN.) (MIN., U.N.O. ON PLAN) DISTRIBUTION HEADER NOTES: 1) FOR SHEARWALL SHEATHING SCREW REQUIREMENTS, SEE SCHEDULE. 2) SEE SECTIONS FOR MORE INFORMATION ON TIEDOWN CONNECTIONS/ANCHORS. STRAP LOCATIONS (TYP.) TIEDOWN ANCHORS ALONG SHEAR WALLS OR ANCHORS/STRAPS AT DIAGONAL STRAP LOCATIONS (TYP.) TIEDOWN ANCHORS ALONG OF SHEARWALL AND AT MIN. ALL ALONG SHEARWALL LINE. EACH SIDE OF OPENING, SHEAR WALLS (OR AT STRAP LOCATIONS)(TYP.) PROVIDE AT ENDS DIAGONAL GALVANIZED STEEL STRAPPING, SEE PLANS, ELEVATIONS AND SECTIONS FOR SIZES AND LOCATIONS. ATTACHMENTS PER MFR. DISTRIBUTION HEADER ALONG WALL. (TYP.) PROVIDE CONT. HSS INSTALL TRACK TIGHT TO TOP OF STUD, CONNECT TO HSS AT EACH STUD AS A MIN. (SEE MFR. RECOMMENDATIONS) (1) 1/2"Ø HILTI KWIK BOLT 3 EXP. ANCHOR (OR EQUAL) @ 4'-0" o/c MAX. (4 3/4" MIN. EMBED.) INTO CONCRETE, OR @ 2'-0" o/c MAX. (3" MIN. EMBED.) INTO GROUT-FILLED CMU, LOCATED IN BETWEEN TIEDOWN ANCHORS AND WITHIN 1'-0" OF EACH END OF EVERY TRACK. NOTE: STRAPS TO BE PRE-TENSIONED. WALL STUD (TYP.) BOTTOM TRACK BOTTOM TRACK HSS DISTRIBUTION HEADER (TYP.) STRAPS FASTENED TO EACH STUD AS REQUIRED PER MFR. (TYP.) BOX STUDS @ TIEDOWN (SEE PLAN/SCHEDULE) (TYP.) STRAP CONNECTION TO BOX STUDS PER MFR. BASED ON LOADS PROVIDED. ADD GUSSET PLATES, ETC. AS REQUIRED (TYP.) STEEL FLAT STRAP, SEE SCHEDULE TIEDOWN ANCHOR CONNECTION, SEE OTHER DETAILS FOR INFO. CONC. SLAB AND METAL DECK TYPICAL DETAIL OF TYP. FLOOR-TO-FLOOR CONNECTION @ DIAGONAL STRAP LATERAL BRACING . TYPICAL WELDED WIRE SUPPORT DETAIL OVER INFILL BEAMS SEE PLAN FOR SLAB DEPTH 3/4" COVER WELDED WIRE FABRIC DRAPED OVER BEAM BOLSTERS (TYPICAL) METAL DECK . SEE PLAN FOR SLAB DEPTH 3/4" COVER ADDITIONAL WELDED WIRE FABRIC OVER GIRDER WELDED WIRE FABRIC OVER BEAMS AT SLAB MID-DEPTH METAL DECK 2'-0" 2'-0" .. . . TYPICAL SLAB REINFORCING AT GIRDERS AND AT BEAMS/GIRDERS ALONG COLUMN LINES (FOR CONCRETE THICKNESS OVER COMPOSITE DECK NOT EXCEEDING 3 1/2") SECTION @ ELEVATOR SILL DECK CAN BE PARALLEL OR PERP. TO BEAM CONT. ž4x4x3/8 ® OF BEAM * * * "*" COORDINATE DIMENSIONS WITH ELEVATOR MANUFACTURER CONT. 5/16" BENT ™ w/ 1/2"Øx4" HEADED STUD @ 2'-0" o/c 2 7/8" 1 15/ 1 6 " 3 1/4" TYPICAL CURTAINWALL SUPPORT DETAIL GRAVITY/LATERAL CONN. BY WINDOW SYSTEM MFR CONC. SLAB ON DECK DIRECTION VARIES SEE SECTIONS WINDOW SYSTEM (SEE ARCH.) 3/8" STIFF. ™, SPACING TO MATCH MULLION LOCATIONS. COORD. w/ WINDOW SYSTEM MFR. (5'-0" o/c MAX.) ž3x3x1/4 w/ 1/4" ™ @ EA. STIFF. ™ 1/4" BENT ™ w/ (2) 1/2"Ø EXP. BOLTS IN FLUTES OF DECK1 2 NOTE: VERTICAL SUPPORT IS ASSUMED TO BE AT EVERY FLOOR. IF THIS IS NOT ACCURATE, NOTIFY STRUCTURAL ENGINEER TO MODIFY STRUCTURAL STEEL DESIGN AS REQUIRED. EXISTING WALL TO BE REMOVED 1/2"Ø THRU-BOLT @ EA. BEARING END STEEL ANGLES (SEE PLAN FOR SIZE) & 2'-0" o/c 8" MIN. BEARING EA. END ON (2) COURSES OF GROUTED CMU @ OPENING INCREMENTS @ 3/16" ™ IN 2'-0" ERECTION SEQUENCE: TYPICAL INSTALLATION OF NEW LINTEL IN EXISTING WALL DETAIL 3) REPEAT STEPS 1 & 2 ON OTHER SIDE. 4) INSTALL 1/2"Ø THRU-BOLTS. 5) INSTALL & WELD 3/16" PLATE TO UNDERSIDE OF CHANNEL IN 2'-0" INCREMENTS AS WALL IS REMOVED. 1) SAWCUT 4" SLOT ON ONE SIDE. 2) INSTALL CHANNEL ON ONE SIDE. 3/16 3@12 ERECTION SEQUENCE: INSTALLATION OF CHANNEL LINTEL 3) REPEAT STEPS 1 & 2 ON OTHER SIDE. 4) INSTALL 1/2"Ø THRU-BOLTS. 5) INSTALL & WELD 3/16" PLATE TO UNDERSIDE OF CHANNEL IN 2'-0" INCREMENTS AS WALL IS REMOVED. 1) SAWCUT 4" SLOT ON ONE SIDE. 2) INSTALL CHANNEL ON ONE SIDE. INCREMENTS @ @ OPENING 3/16" ™ IN 2'-0" EXISTING WALL TO BE REMOVED 1/2"Ø THRU-BOLT @ EA. BEARING END & 2'-0" o/c STEEL CHANNELS (SEE PLAN FOR SIZE) 3/16 3@12 TYPICAL DETAIL FOR OPENINGS IN WEB OF STEEL BEAMS SCALE: 3/4" = 1'-0 DRAWING: \FRM\S8 3xd 4d HL ® OPENING® OPENING 1/2 OF OPENING HEIGHT, TOP & BOTT., 2" MIN. (TYP.) 2'-0 3/8"D= MINIMUM CLEAR @ CONNECTION OR POINT LOAD, TYP. EDGE OF CONNECTION MATERIAL TYP. 1/2" M A X .1/2" MAX. TYP. 3xL SEE PLAN FOR BEAM SIZE NOTE: ALL HOLES IF POSSIBLE SHALL BE LOCATED IN THE MIDDLE THIRD OF SPAN. 1) IF THE OPENING IS IN THE MIDDLE THIRD OF THE SPAN AND: a) "d" OR "L" OR "H" IS 1/4 D OR SMALLER - NO REINFORCEMENT IS REQUIRED. b) "d" OR "L" OR "H" IS LARGER THAN 1/4 D BUT SMALLER THAN OR EQUAL TO 1/3 D - ADD WEB REINFORCING PLATE SAME THICKNESS ON ONE SIDE ONLY (3/8" MIN.). c) "d" OR "L" OR "H" IS LARGER THAN 1/3 D - SEE STIFFENER REINFORCEMENT DETAIL. 2) IF THE OPENING IS LOCATED OUT OF THE MIDDLE THIRD OF THE SPAN AND: a) "d" OR "L" OR "H" IS 1/6 D OR SMALLER - NO REINFORCEMENT IS REQUIRED. b) "d" OR "L" OR "H" IS LARGER THAN 1/6 D BUT SMALLER THAN OR EQUAL TO 1/4 D - ADD WEB REINFORCING PLATE SAME THICKNESS ON ONE SIDE ONLY (3/8" MIN.) c) "d" OR "L" OR "H" IS LARGER THAN 1/4 D - SEE STIFFENER REINFORCEMENT DETAIL. (UNREINFORCED OR DOUBLER PLATE REINFORCING)dD3 13 / 1 6 " 1/4 TYP. TYPICAL WF COLUMN CONNECTION TO TRANSFER GIRDER COLUMN WEB PARALLEL TO GIRDER WEB COLUMN WEB PERPENDICULAR TO GIRDER WEB 1" TYP. COLUMN 3/4" BASE ™ w/ (4) BOLTS 1 1/2" MIN. BASE ™ w/ (4) BOLTS FITTED STIFF. ™, BOTH SIDES TRANSFER GIRDER NOTE: 1) STIFFENER ™ THICKNESS TO MATCH COLUMN FLANGE THICKNESS. FITTED STIFF. ™, BOTH SIDES TRANSFER GIRDER 1 1/ 16" COLUMN TYPICAL BOLTED BEAM TO COLUMN FLANGE GRAVITY MOMENT CONNECTION "k" SHIM (IF REQ'D), 1/4" MAX. THK. PERMITTED FLANGE BOLTS STIFFENER ™'s, WIDTH & THICKNESS TO MATCH FLANGE ™'s FLANGE ™'s (T&B) TYP. SHEAR CONNECTION TYP. NOTES: 1) DETAILS SHOWN ARE NOT FULLY DESIGNED AND DETAILED AND ARE CONCEPTUAL IN NATURE. STEEL FABRICATOR'S ENGINEER TO FULLY DESIGN AND DETAIL MOMENT CONNECTIONS FOR FORCES SHOWN ON PLAN. THIS INCLUDES FLANGE PLATES, BOLTS AND WELDS. (IF NO FORCE IS SHOWN, DESIGN FOR FULL CAPACITY OF BEAM). 2) WELDS CAN BE SUBSTITUTED FOR BOLTS. 3) BOLTS SHALL BE ASTM A325/A490-SC, WITH STANDARD SIZE HOLES IN BEAM. 4) STEEL FABRICATOR TO PROVIDE DECK SUPPORT AS REQUIRED. 7/8" SS ROC PROFE . AI GNNIOLAE RER SASTATE OF 860325 NNID No. A ENI R M I ED EG N TSE Y MOC DE c SHEET TITLE SHEET NUMBER RATIO 101 South Pennsylvania Street Indianapolis, Indiana 46204 317-633-4040 Architect McComas/O'Donnell & Naccarato Structural Engineer 1717 E. 116th Street, Suite 200 Carmel, Indiana 46032 317-580-0402 PROJECT NO. SHEET ISSUE SEAL | DATE COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE, DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED. THESE ARE PROGRESS DRAWINGS, THEREFORE THEY ARE ISSUED PRIOR TO COMPLETION OF THE STRUCTURAL DESIGN AND OTHER DESIGN DISCIPLINES INCLUDING BUT NOT LIMITED TO ARCHITECTURAL OR MECHANICAL DESIGNS; AND AS SUCH, ARE INCOMPLETE BY NATURE FOR THE COMPREHENSIVE SCOPE OF THE PROJECT. ALLOWANCES FOR STRUCTURAL ELEMENTS REQUIRED DUE TO THE COMPLETION AND CROSS-COORDINATION OF ALL OTHER DISCIPLINES SHOULD BE MADE. 1717 EAST 116TH STREET | SUITE 200 | CARMEL, IN. 46032 (317) 580-0402 | WWW.O-N.com | Project No. 7167.0014.00 SHELL & CORE PERMIT SET 10/15/2021 Mechanical / Plumbing Design/Builder Civil Engineer DEEM LLC 6831 E 32nd Street Indianapolis, Indiana 46226 Kimley Horn 250 East 96th Street, Suite 580 Indianapolis, Indiana 46240 Electrical Design/Builder Barth Electric Co., Inc. 1934 N. Illinois Street Indianapolis, Indiana 46202 Kite Realty Group 30 S. Meridian Street, #1100 Indianapolis, Indiana 46204 Owner Republic Airways Holdings 8909 Purdue Road, Suite 300 Indianapolis, Indiana 46268 10/15/2021 2:14:48 PMS-402 TYPICAL FRAMING DETAILS 0-N 7167.0014.00 Republic Airways Hotel 12197 N Meridian St. Carmel, IN 46032 1 DESIGN DEVELOPMENT 10/01/21 2 SHELL & CORE PERMIT SET 10/15/21 10/15/21 10/19/22