Loading...
HomeMy WebLinkAboutC100 COVER SHEETDUMPSTERENCLOSURE PATIO 20' BMP ESMT20' BMP ESMT PROJECT NO. CHECK:DRAWN: PLAN DATE: DESIGN: STATE OF No. PE10707583 OO14020 Mississinewa Drive Carmel, Indiana 46033 P: 317.324.8695 F: 317.324.8717 www.Fritz-Eng.com Fritz Engineering Services, LLC REVISIONS AND ISSUES BYDATE CLIENT: PROJECT: PROJECT LOCATION: GENERAL NOTES / LEGEND: SECTION, TOWNSHIP, RANGE: LAKEFRONT COURT 2 CARMEL SCIENCE & TECHNOLOGY PARK DAVID RAUSCH STUDIO 170 S. MAIN STREET ZIONSVILLE, IN 46077 5/18/2022 2204001 LAKEFRONT COURT CARMEL, INDIANA 46032 HAMILTON COUNTY NW 1 4, S36 , T18N, R3E SHEET NAME SHEET NO. PRELI MI N A R Y NOT F O R CONS T R U C TI O N ©2022 FRITZ ENGINEERING SERVICES, LLCN PLANS PREPARED FOR: DAVID RAUSCH STUDIO 170 S. MAIN STREET ZIONSVILLE, IN 46077 Contact Person: DAVID RAUSCH (317) 873-4970 DAVID@DAVIDRAUSCH.COM CONSTRUCTION PLANS FOR: LAKEFRONT COURT 2 CARMEL SCIENCE & TECHNOLOGY PARK LAKEFRONT COURT CITY OF CARMEL, CLAY TOWNSHIP, HAMILTON COUNTY, INDIANA NW 1 4, SECTION 36, TOWNSHIP 18N, RANGE 3E SITE VICINITY & ZONING MAP FLOOD ZONE: THE PROJECT SITE IS LOCATED WITHIN THE FEMA COMMUNITY PANEL MAP #18057C0209G DATED NOVEMBER 19, 2014. REVIEW OF THE MAP INDICATES THE SITE IS LOCATED WITHIN THE FLOOD DESIGNATIONS 'ZONE X' (UNSHADED). THE PROPOSED BUILDINGS AND IMPROVEMENTS ARE LOCATED IN ZONE X UNSHADED AND ARE THEREFORE NOT SUBJECT TO FLOOD CONTROL ORDINANCE REQUIREMENTS. NOT TO SCALE SITE LOCATION M3 SITE DATA: TOTAL SITE ACREAGE - 0.96 AC TOTAL ACREAGE OF DISTURBANCE - 0.86 AC GROSS SQUARE FOOTAGE OF PROPOSED BUILDING - 8,000 PROPOSED CONSTRUCTION START - JULY 1, 2022 PROPOSED CONSTRUCTION END - JULY 1, 2023 WORK TO BE COMPLETED IN ONE CONTINUOUS CONSTRUCTION PHASE SETBACKS:REQUIRED PROVIDED FRONT YARD 20 FT (CARMEL DR)22.8 FT 20 FT (LAKEFRONT CT,E)22.6 FT 20 FT (LAKEFRONT CT,S)75 FT ± SIDE YARD 20 FT 66.5 FT (WEST) REAR YARD 20 FT N/A (NO REAR YARD) N C100 COVER SHEET 1.REV PER TAC COMMENTS 7/7/2022 AF AF AF KG GENERAL NOTES: 1.THE CONSTRUCTION PLANS SHALL GOVERN OVER ANY OTHER FORM OF MEDIA, WHICH INCLUDES DIGITAL FILES OF THIS PROJECT. 2.THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING OR VERIFYING THAT ALL PERMITS AND APPROVALS ARE OBTAINED FROM THE RESPECTIVE CITY, COUNTY, STATE & FEDERAL AGENCIES PRIOR TO STARTING CONSTRUCTION. 3.IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO DETERMINATE THE EXACT LOCATION OF ALL EXISTING UTILITIES IN THE VICINITY OF THE CONSTRUCTION AREA PRIOR TO STARTING CONSTRUCTION. ONCE ALL UTILITIES HAVE BEEN LOCATED, IT WILL BE THE CONTRACTOR'S RESPONSIBILITY TO MAINTAIN IN SERVICE ALL EXISTING UTILITIES ENCOUNTERED DURING CONSTRUCTION UNLESS OTHERWISE INDICATED IN THE CONSTRUCTION DRAWINGS. 4.BEFORE WORKING WITH OR AROUND EXISTING UTILITIES, THE APPLICABLE UTILITY COMPANY SHALL BE CONTACTED BY THE CONTRACTOR. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY AND COORDINATE CONSTRUCTION WITH ALL RESPECTIVE UTILITIES. 5.ALL CONSTRUCTION METHODS AND MATERIALS MUST CONFORM TO CURRENT STANDARDS AND SPECIFICATIONS FOR THE GOVERNING MUNICIPALITY REQUIREMENTS. 6.MAINTENANCE OF TRAFFIC NEEDED FOR THIS PROJECT SHALL BE INSTALLED AND MAINTAINED PER INDOT SPECIFICATIONS AND THE INDIANA MUTCD MANUAL. 7.THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL FIELD DIMENSIONS AND SHALL VERIFY ALL DIMENSIONS ON THE SITE PRIOR TO START OF CONSTRUCTION. IF ANY DISCREPANCIES ARE FOUND IN THESE PLANS FROM ACTUAL FIELD CONDITIONS, THE CONTRACTOR SHALL NOTIFY THE ENGINEER IMMEDIATELY. 8.ALL QUANTITIES GIVEN ON THESE CONSTRUCTION PLANS OR IN THE SCOPE OF WORK SECTION ARE ESTIMATES AND SHALL BE CONFIRMED BY THE BIDDING CONTRACTORS. 9.IT SHALL BE THE RESPONSIBILITY OF THE DEVELOPER AND CONTRACTOR TO MAINTAIN QUALITY CONTROL THROUGHOUT THIS PROJECT. 10.BEARINGS, DIMENSIONS, AND EASEMENTS ARE SHOWN FOR REFERENCE ONLY. SEE RECORD SURVEYS AND PLATS FOR EXACT INFORMATION. SITE LOCATION SURVEY CONTROL & BENCHMARK DATA: STATE PLANE INDIANA EAST, US FOOT, NAD83, CORS96 SITE BENCHMARK: TBM #1, PT 702, MAGNAIL SET IN SIDEWALK NEAR SW CORNER OF SITE N: 1718211.48 , E:194433.70 ELEV = 841.99 (NAVD 88) 4'± SOUTH OF SOUTH PROPERTY LINE & 13'± EAST OF WEST PROPERTY LINE. ORIGINATING BENCHMARK FROM SURVEY: NORTH CORNER OF THE SW 1 4 OF SECTION 36, TWP 18N, RANGE 3E, DATED 07-11-2007, #5 REBAR AT TOP OF BANK SHOWN ON SECTION CORNER NUMBER 18033617 N: 1717824.498, E: 195125.875, ELEV=833.683 SURVEY DATA PROVIDED BY AXIS SURVEYING, JOB #1-24329 PLAN SHEET INDEX SHEET NUMBER SHEET TITLE C100 COVER SHEET C101 GENERAL INFORMATION PLAN C102 EXISTING CONDITIONS AND DEMO PLAN C102A SURVEY (BY OTHERS) C201 SITE LAYOUT PLAN C301 GRADING PLAN C302 DRAINAGE PLAN C401 SITE UTILITY PLAN C402 STORM PLAN & PROFILE C501 INITIAL CONTROLS SWPPP C502 MASS GRADING & CONSTRUCTION SWPPP C503 POST CONSTRUCTION SWPPP C504 EROSION CONTROL DETAILS C505 SWPP SPECIFICATIONS C801 GENERAL DETAILS C802 CARMEL CURB & PAVEMENT DETAILS C803 ADA RAMP DETAILS C804 TRICO SANITARY DETAILS C805 WATER & STORM DETAILS C806 WATER QUALITY DETAILS C901 GENERAL SPECIFICATIONS C902 CARMEL CURB & PAVING POLICY L101 LANDSCAPE PLAN & PLANTING DETAILS OPERATING AUTHORITIES: COUNTY LOCATION MAP M3 M3 M3 M3 TBM #2, PT 704, MAGNAIL SET TO SOUTHEAST OF SITE N: 1718176.21 , E:194683.12 ELEV = 838.25 (NAVD 88) 10'± SOUTH OF SOUTH PROPERTY LINE & 46'± EAST OF EAST PROPERTY LINE. CITY OF CARMEL CONSTRUCTION STANDARDS AND SPECIFICATIONS, LATEST EDITION, TO BE USED AS SUPPLEMENTAL INFORMATION WITH THESE PLANS. INDIANA STATE DEPARTMENT OF TRANSPORTATION STANDARD SPECIFICATIONS, LATEST EDITION, TO BE USED AS SUPPLEMENTAL INFORMATION WITH THESE PLANS. CARMEL ENGINEERING DEPARTMENT NOTE: ALL PAVING WITHIN THE EXISTING AND PROPOSED CITY RIGHT-OF-WAY SHALL CONFORM TO THE REQUIREMENTS OF THE DEPARTMENT OF ENGINEERING. THE CONTRACTOR SHALL CONTACT THE DEPARTMENT OF ENGINEERING TO SCHEDULE A PRE-CONSTRUCTION MEETING TO REVIEW THE DEPARTMENT'S CONSTRUCTION REQUIREMENTS, STAFF NOTIFICATION REQUIREMENTS, REQUIRED INSPECTIONS FOR CERTAIN STAGES OF THE WORK AND TO REVIEW THE AUTHORITY OF THE DEPARTMENT AS IT RELATES TO WORK WITHIN THE EXISTING AND PROPOSED RIGHT-OF-WAY. EXISTING RIGHT OF WAY NOTE: DAMAGE TO THE EXISTING RIGHT-OF-WAY SHALL BE RESTORED/REPAIRED TO THE SATISFACTION OF THE CITY AT THE COMPLETION OF THE PROJECT. THE CONTRACTOR IS ENCOURAGED TO INSPECT THE RIGHT-OF-WAY WITH THE CITY PRIOR TO THE START OF CONSTRUCTION TO DOCUMENT THE EXISTING CONDITION OF THE RIGHT-OF-WAY. CARMEL PETITION REFERENCE: DOCKET NO. PZ-2022-00090 DP ADLS DOCKET NO. STORMWATER PERMIT: CARMEL UTILITIES 30 West Main Street Carmel, IN 46032 (317) 571-2442 (Customer Service) CITIZEN'S ENERGY GROUP 2150 Dr. Martin Luther King Jr. Street indianapolis, IN 46202 (317) 263-6418 CARMEL DEPARTMENT OF COMMUNITY SERVICES 1 Civic Square Carmel, IN 46032 (317) 571-2417 DUKE ENERGY 100 South Mill Creek Road Noblesville, Indiana 46060 (317) 776-5365 VECTREN 16000 Allisonville Road Noblesville, Indiana 46061 (317) 776-5532 CARMEL DEPARTMENT OF ENGINEERING 1 Civic Square Carmel, IN 46032 (317) 571-2411 COMCAST 5330 E. 65th Street Indianapolis, IN 46220 (317) 774-3384 TRICO REGIONAL WASTE 10701 N College Ave, Suite A Indianapolis, IN 46280 "IT'S THE LAW" R Know what's below. Call before you dig. 2 WORKING DAYS BEFORE YOU DIG.PRINTED BY: Ashton FritzDATE: 7/8/2022 3:06 PMSHEET SIZE, SCALE: ANSI FULL BLEED D (34.00 X 22.00 INCHES), 1:1FILE NAME: F:\2022\2204001 - LAKEFRONT COURT 2\02 CIVIL\PLANS\C100.DWG, LAYOUT: COVER SHEET