HomeMy WebLinkAboutA3-0 - ROOF PLANGENERAL ROOFING NOTES
1. THESE GENERAL NOTES APPLY TO ROOF DRAWINGS.
2. VERIFY SIZE, LOCATION AND NUMBER OF ROOF PENETRATIONS INCLUDING
VENTS, PIPES, CURBS, ROOF DRAINS, CONDUITS, ETC. PROVIDE NEW FLASHING
AND SEAL PENETRATIONS WHETHER OR NOT INDICATED ON THE DRAWINGS.
3. COMPLETE WORK ABOVE ROOF, SUCH AS MASONRY, WELDING, MASONRY
RESTORATION, ETC., PRIOR TO STARTING ROOFING WORK.
4. VERIFY AND MAINTAIN ROOF SLOPES AND DRAINAGE PATTERNS. TEST FOR
AND CORRECT ANY PONDING CONDITIONS.
5. REPAIR AND REPLACE ROOFING SYSTEM OR STRUCTURE DAMAGED BY
IMPROPER STORAGE, CONSTRUCTION ACTIVITIES, OR LACK OF ADEQUATE
TEMPORARY PROTECTION. THIS ALSO INCLUDES INTERIOR DAMAGE TO FINISHES,
EQUIPMENT, FURNISHINGS, ETC., RESULTING FROM LEAKS.
6. BLOCKING SHALL BE PRESERVATIVE-TREATED WOOD.
7. PAINT EXTERIOR LADDERS, BRACKETS, ETC., UNLESS NOTED OTHERWISE.
8. CAP FASTENERS THAT PENETRATE ROOF DECK IN AREAS NOT CONCEALED BY
CEILINGS WITH WIRE NUTS OR OTHER MEANS ACCEPTABLE TO ARCHITECT UNLESS
OTHERWISE INDICATED. AREAS SUCH AS JANITOR CLOSETS, STORAGE ROOMS,
MECHANICAL AND ELECTRICAL EQUIPMENT ROOMS, ETC., ARE EXEMPT FROM THIS
REQUIREMENT UNLESS OTHERWISE INDICATED.
9. REFER TO WALL SECTIONS NOTED ON ROOF PLANS FOR INFORMATION.
10. REFER TO MECHANICAL DRAWINGS TO COORDINATE MECHANICAL UNIT
LOCATIONS.
A5.12
A5.1
A5.0
A5.0
3
4
1
1
A6.0
HH
EE
DD
CC
BB
AA
11
4
4
5
5
6
6
7
7
8
810
1
A6.1
3
A6.1
3.9
FF
GG
2
A6.1
2
A6.0
1
A7.1
4
A7.1
3
A7.1
2
A7.1
1
A7.2
3
A6.0
1
A7.3
2
A7.3
4
A7.3
3
A7.0
2
A7.0
1
A7.0
3
A7.3
A1.0 5
1/4" / 1'-0"1/4" / 1'-0"1/4" / 1'-0"1/4" / 1'-0"1/4" / 1'-0"
1/8" / 1'-0"
RECESSED METAL
BOX GUTTER AND
DOWNSPOUTS
ROOF LOW
POINT FOR
INTERNAL ROOF
ROOF DRAINS
3x3 METAL BOX GUTTER,
DIVERT WATER TO BACK
AND DIRECT TO RAIN CHAIN
9
METAL PANEL
PARAPET WALL
METAL PANEL
SCREEN
TOP OF PARAPET 20'
17'4"15'4"
13'4"
16'4"
15'4"
SCREEN WALL TOP 20'
12" OPEN WEB JOISTS BEAR AT 12'4 1/2"
PLUS INSULATION = BOTTOM OF HVAC
UNIT 14' TOP OF HVAC UNIT 20'
BOTTOM OF STRUCTURE 12'4"
CEILING 9'0"
CLEAR INTERSTICIAL SPACE 32"
RTU
RTU
RTU
RTU
SURGERY RTU
RTU
RTU
LOBBY
PERIMETER
PRELIMINARY
NOT FOR PERMIT
OR CONSTRUCTION
COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING
DRAWING IS GIVEN IN CONFIDENCE AND SHALL BE USED ONLY
PURSUANT TO THE AGREEMENT WITH DAVID RAUSCH STUDIO
LLC. NO OTHER USE, DISSEMINATION OR DUPLICATION MAY BE
MADE WITHOUT PRIOR WRITTEN CONSENT OF DAVID RAUSCH
STUDIO LLC. ALL COMMON LAW RIGHTS OF COPYRIGHT AND
OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.
ISSUE DATE:
DAVID RAUSCH STUDIO LLC
ARCHITECT
170 S. MAIN STREET
ZIONSVILLE, INDIANA 46077
PHONE: 317.873.4970
WWW.DAVIDRAUSCH.COM
LAKEFRONT COURT
DR. RON MILLER AND DR. BURKE CHEGAR
OWNER
BCRM PROFESSIONAL PARTNERS, LLC
715 WEST CARMEL DRIVE
CARMEL, INDIANA 46032
PHONE: 317.818.5438
STRUCTURAL ENGINEER
FRITZ ENGINEERING SERVICES
CIVIL ENGINEER
14020 MISSISSINEWA DRIVE
CARMEL, INDIANA 46033
PHONE: 317.324.8695
WWW.FRITZ-ENG.COM
FINK ROBERTS & PETRIE, INC.
3535 EAST 96TH STREET, SUITE 126
INDIANAPOLIS, INDIANA 46240
PHONE: 317.872.8400
WWW.FRPINC.COM
2
735 WEST CARMEL DRIVE
CARMEL, INDIANA 46032
CONTRACTOR
GENESIS ENGINEERING GROUP
MECHANICAL & ELECTRICAL ENGINEER
95 S. MAIN STREET
ZIONSVILLE, INDIANA 46077
PHONE: 317.927.8307
WWW.GENESIS-ENGINEERING.COM
CAPITOL CONSTRUCTION SERVICES, INC.
11051 VILLAGE SQUARE LANE
FISHERS, INDIANA 46038
PHONE: 317.574.5488
WWW.CAPITOLCONSTRUCT.COM
DAVID RAUSCH STUDIO LLC
INTERIOR DESIGNER
170 S. MAIN STREET
ZIONSVILLE, INDIANA 46077
PHONE: 317.873.4970
WWW.DAVIDRAUSCH.COM
ROOF PLAN
A3.0
July 7, 2022
1/8" = 1'-0"2 ROOF PLAN
KEYNOTE LEGEND
NO. NOTE