Loading...
HomeMy WebLinkAbout06050150 Site Plan .~~ Schneider The Schneider Corporation 8901 0Us inDue H1storIc Fort Harrison Indlanapollo. indiana 48216-10:l'1 317-828-7100 317-626-7200 fAX EDgIneerlna ~ lAn_po .ltcldteeture GIS .IJS GeolOO This Plot Plan Prepared for: R.H. of Indiana Lot # 70 . containing 6,764 SJ.:f:. in Stanford Park Section I 1 INSlR. I 200500009385 P.C. I 3, Slide I sn CERTIFlCA 1E of CORRECTION INSlR. I 200500044195 Oay Twp, HamDton County Sec 29, TI8N, RJE 3492 Modesto Lone Carmel, IN 46074 Prepared Dote: 05/10/06: By: JKI Proposed Bu)'llr(s): Inventory Plot Plan Legend (50'RjW) []Q[Q] Proposed Grodes 000.0 Existing Grodes __000.0-- Contour Grade * Approx. lateral Location - . - Sanitary Sewer lines -IT - Storm Sewer lines - 1,/ - Water Service lines - - - - - - - Sub-Surface Drain Lines . Manhole (Sanitary or Storm) . Beehive Inlet (Stann) 11III Curb Inlet (Stonn) D End Section (Storm) .... Fire Hydront - .. .. .. - .. .. .. - flow line of swole Building Une (BL / BSL) - - - - - - - Easement Line Community Restrictions: Side Yard =3' min. Rear Yard' N/A Aggregale = 6' (B.H.) Note: Sanitary Sewer Top of Costing Information Upstream Manhole. TC= 914,90 Downstream Manhole. TC=916,20 per plan. R.H. of Indiana Finished Floor Elevation Information Pad Grade = 915.6 per plan Pad Grade + 0.7' = Garage FFE (916.3) Garage FFE + 1.5' = Residential FFE (917,B) Residential FFE - 9.0' = Basement FFE (90B,B) Note: Per Carmel zoning ordinance 26.1,1 : The residential district limits height to twenty-five feet (25'). however (I dwelling moy be increased in height to thirty-five feet (35') provided the side and rear ~rds ore increased on additional one foot (1') for each one foot (1') the structure exceeds the first twenty-five feel (25') in hei9ht. Note : The garage finished floor elevation is lA' above the curb at the drive, per pion. Ground Cover Calculations Drive = 513 SF! Public Walk = 201 SF! Privote Waik = 40 SF! Hydroseeding =1.4C0 SF! Sod = 203 SYf. from Rear of residence. Add, Sod = 157 SYf, from sod line. , 10' LM.A. 56.00 1913.51 15' O.E, 7.6' 1914.21 AOo.-SOO - - w: AOO. SOO 1914.61 12.00' 13 OECI< ~ N :I'" 0-1. Note: The contractor is to maintain a minimum distance of ten feet (10') between the sonitry sewer and water line laterols. SOO 19.67 ASPEN C fR~ & ~S1' '" RE90ENC[ N ~ 1 .50 8 . 9,63 .,: .... SOO BSlINT 1\\l) CAR GARAt;[ 6,0 26.0 2JO: 915.0 . 5' WALK <: I APRON ----- 11l~ ElEV=914,9 1914.931 /' 30.0' 8-a <: MODESTO LANE ----------- --- Flood Hazard Statement: The accuracy of any flood hazard data shown on this report is subject to map scale uncertainty and to any other uncertainty in location or elevation on the referenced flood insurance rate map. ALL of the within described land DOES NOT LIE within that special flood hazard zone A as said land plots by scale on flood insurance rale map # 18057 0205F for City of Carmel, Indiana (maps dated February 19, 2003). 9GNA TURE : DATE: SIGNATURE REPRESOITS CONRRMATION Of RECEIPT Of PLOT PlAN BY CUSTOMER, Note: This drawing is based on construction plans or record drawings, and is not based upon a field survey. The Schneider Carporation does not worrant the accuracy or sufficiency of this information. Contractors should verify existing conditions prior to any construction. Any discrepancy found on this drawing should be reported to The Schneider Corporation immediately; foning to do so results in the contractors assumption of all liability. Note: The basement elevation, depicted hereon, has been determined and based upon the pad grades and/or contours taken from the construction plans for this subdivision. Unless stated, no information about fluctuating water tables, soli conditions, or son twes has been provided or stated on said plans. It is recommended that the basement finished floor elevations be at least two feet (2') above the normal pool elevation of any adpining bodies of woter, unless 0 study of facts reveals otherwise. If during- the excavation process any ground water is witnessed, The Schneider Corporation should be notified immediately, The basement elevation shoold be raised two feet (2') obove the ground water, and additional construction techniques should be incorporated to alleviate future problems. Note: Sump pump(s) to be placed by bunder os needed. o ~ =Ji:51= Lot # 70 VB06.0054123 o Sidewalk to be placed " from property line, 4' from bock of curb, per plan. Assumed North Scale: 1" = 30' Oelol of Ground/ Slorm Water flaw pattem for indlviduollats. I I :p: I I Note: Builder to ensure positive drainage away ~om structure(s). ~H /729 TC-914.90 PER PlAN ROlL CURB FLOOD HAZARD STATEMENT CERllFICA llON ,\II\II\\IIIIIIIIIIIi/III///1. ~~'\ c.. L /l I'ij~ ;i>~':~ . 1/,LJh~ ~~~"' ...............'(v,/.,,'0;; ~<..~..tG\ST€"Jy~....~A~ "'~...<I- No 0',,;<>,", i ( 50303 ....) i % \. STATE OF ..... Jj ~ /", ....C\ ~ ~(~....f.tvO'At.\~... ~~~ % '1tJ "S"'U'''o,i '- ~ # ~ijl/, 1\' ~\~~ '//i/II/IIIIIIIIIIIIII\II\\ Oo-l,r-v ~ TYPIC....L SWALE SECTlON