HomeMy WebLinkAboutS201 - GarveyBEDROOM
MASTER
8'-0"
201
BATHROOM
MASTER
VARIES
202
CLOSET
8'-0"
202
KITCHEN
9'-0"
101
GREAT ROOM
VARIES
100
MUD ROOM
9'-0"
102
RESTROOM
9'-0"
103
CORRIDOR
9'-0"
103
A202REFLECTED CEILINGPLANSecond Level Reflected Ceiling Plan
Scale: 1/4" = 1'-0"
02
A202 SHEET NO.DRAWN BY.CHECKED BY. TGJ
COPYRIGHT: Architects Forum, LLC expressly reserves the common
law copyright and other property rights in these plans. These plans
are not to be reproduced in any form or manner, nor assigned to any
third party, without first obtaining the expressed permission and
consent of Architects Forum, LLC.PROJECT NO.220510HA8555 North River Road .Suite 220 . Indianapolis . Indiana . 46240[p] 317. 842.8500 [f] 317.842.8877MICHAEL & CAROLINE'SRESIDENCE1193 HELFORD LANECARMEL, INDIANA 46032CERTIFIED BY.DATE:REVISIONS:SEPTEMBER 22, 2022PERMIT SETSEPTEMBER 22, 2022First Level Reflected Ceiling Plan
Scale: 1/4" = 1'-0"
01
A202
GENERAL CEILING NOTES
CEILING LEGEND
CEILING PLAN NOTES
LIGHT FIXTURE SCHEDULE
* ALL LIGHT FIXTURES ARE TO BE LED UNLESS NOTED
OTHERWISE.
GYPSUM BOARD
2X4 SUSPENDED ACOUSTICAL PANEL CEILING
(REFERENCE FINISH SCHEDULE FOR TYPE)
2X2 SUSPENDED ACOUSTICAL PANEL CEILING
(REFERENCE FINISH SCHEDULE FOR TYPE)
2X2 HVAC RETURN AIR GRILLE
(REFERENCE MECHANICAL SCHEDULE)
2X2 LED LAY-IN LIGHT FIXTURE
(REFERENCE ELECTRICAL SCHEDULE)
STRIP LIGHT FIXTURE
RECESSED LED CAN LIGHT FIXTURE
LED PENDANT LIGHT FIXTURE
EXIT LIGHT FIXTURE
2X4 LED LAY-IN LIGHT FIXTURE
(REFERENCE ELECTRICAL SCHEDULE)
2X2 HVAC DIFFUSER
(REFERENCE MECHANICAL SCHEDULE)
A. ALL WALLS EXTEND TO DECK UNLESS NOTED AS FOLLOWS:
WALLS TO 6" ABOVE CEILING HEIGHT
WALLS TO JOISTS ABOVE
WALLS TO DECK ABOVE
B. LIGHT FIXTURE AND DIFFUSERS ON DRAWINGS SHOWN FOR
LOCATION ONLY. COORDINATE WITH MECHANICAL AND
ELECTRICAL DRAWINGS FOR EXACT SPECIFICATIONS AND
VERIFICATION OF QUANTITY.
C. ALL CEILING ARE TO BE INSTALLED AT 9'-1" UNLESS NOTED
OTHERWISE.
D. CENTER ACOUSTICAL CEILING PANELS IN EACH DIRECTION
WITH THE MAIN PORTION OF ANY ROOM OR SPACE, UNLESS
NOTED OTHERWISE.
6"
J
D
RESPONSIBILITY LEGEND
C.F.C.I. CONTRACTOR FURNISHED, CONTRACTOR INSTALLED
TENANT FURNISHED, CONTRACTOR INSTALLED
VENDOR FURNISHED, CONTRACTOR INSTALLED
T.F.C.I.
V.F.C.I.
FIXTURE MANUFACTURER RESP.STYLE NUMBER STYLE NAME
-
-F1 -
-
-
-C.F.C.I.
-
-F2 -
-
-
-C.F.C.I.
NEW GYPSUM DRYWALL BULKHEAD LOCATION. ALIGN EDGE OF
BULKHEAD TO ADJACENT WALLS.
PROVIDE DIMMABLE FIXTURES AND CONTROLS.
CEILING FAN LOCATION. PROVIDE 2X BLOCKING AS REQUIRED FOR
SECURE INSTALLATION.
1
2
3
PROJECT KEY MAP
PROJECT LOCATION
PAINT WOOD SUPPORT
(EXPOSED).
FINISH W/ PAINTED
WOOD SLATS
1
1
10/28/22