Loading...
HomeMy WebLinkAboutS201 - GarveyBEDROOM MASTER 8'-0" 201 BATHROOM MASTER VARIES 202 CLOSET 8'-0" 202 KITCHEN 9'-0" 101 GREAT ROOM VARIES 100 MUD ROOM 9'-0" 102 RESTROOM 9'-0" 103 CORRIDOR 9'-0" 103 A202REFLECTED CEILINGPLANSecond Level Reflected Ceiling Plan Scale: 1/4" = 1'-0" 02 A202 SHEET NO.DRAWN BY.CHECKED BY. TGJ COPYRIGHT: Architects Forum, LLC expressly reserves the common law copyright and other property rights in these plans. These plans are not to be reproduced in any form or manner, nor assigned to any third party, without first obtaining the expressed permission and consent of Architects Forum, LLC.PROJECT NO.220510HA8555 North River Road .Suite 220 . Indianapolis . Indiana . 46240[p] 317. 842.8500 [f] 317.842.8877MICHAEL & CAROLINE'SRESIDENCE1193 HELFORD LANECARMEL, INDIANA 46032CERTIFIED BY.DATE:REVISIONS:SEPTEMBER 22, 2022PERMIT SETSEPTEMBER 22, 2022First Level Reflected Ceiling Plan Scale: 1/4" = 1'-0" 01 A202 GENERAL CEILING NOTES CEILING LEGEND CEILING PLAN NOTES LIGHT FIXTURE SCHEDULE * ALL LIGHT FIXTURES ARE TO BE LED UNLESS NOTED OTHERWISE. GYPSUM BOARD 2X4 SUSPENDED ACOUSTICAL PANEL CEILING (REFERENCE FINISH SCHEDULE FOR TYPE) 2X2 SUSPENDED ACOUSTICAL PANEL CEILING (REFERENCE FINISH SCHEDULE FOR TYPE) 2X2 HVAC RETURN AIR GRILLE (REFERENCE MECHANICAL SCHEDULE) 2X2 LED LAY-IN LIGHT FIXTURE (REFERENCE ELECTRICAL SCHEDULE) STRIP LIGHT FIXTURE RECESSED LED CAN LIGHT FIXTURE LED PENDANT LIGHT FIXTURE EXIT LIGHT FIXTURE 2X4 LED LAY-IN LIGHT FIXTURE (REFERENCE ELECTRICAL SCHEDULE) 2X2 HVAC DIFFUSER (REFERENCE MECHANICAL SCHEDULE) A. ALL WALLS EXTEND TO DECK UNLESS NOTED AS FOLLOWS: WALLS TO 6" ABOVE CEILING HEIGHT WALLS TO JOISTS ABOVE WALLS TO DECK ABOVE B. LIGHT FIXTURE AND DIFFUSERS ON DRAWINGS SHOWN FOR LOCATION ONLY. COORDINATE WITH MECHANICAL AND ELECTRICAL DRAWINGS FOR EXACT SPECIFICATIONS AND VERIFICATION OF QUANTITY. C. ALL CEILING ARE TO BE INSTALLED AT 9'-1" UNLESS NOTED OTHERWISE. D. CENTER ACOUSTICAL CEILING PANELS IN EACH DIRECTION WITH THE MAIN PORTION OF ANY ROOM OR SPACE, UNLESS NOTED OTHERWISE. 6" J D RESPONSIBILITY LEGEND C.F.C.I. CONTRACTOR FURNISHED, CONTRACTOR INSTALLED TENANT FURNISHED, CONTRACTOR INSTALLED VENDOR FURNISHED, CONTRACTOR INSTALLED T.F.C.I. V.F.C.I. FIXTURE MANUFACTURER RESP.STYLE NUMBER STYLE NAME - -F1 - - - -C.F.C.I. - -F2 - - - -C.F.C.I. NEW GYPSUM DRYWALL BULKHEAD LOCATION. ALIGN EDGE OF BULKHEAD TO ADJACENT WALLS. PROVIDE DIMMABLE FIXTURES AND CONTROLS. CEILING FAN LOCATION. PROVIDE 2X BLOCKING AS REQUIRED FOR SECURE INSTALLATION. 1 2 3 PROJECT KEY MAP PROJECT LOCATION PAINT WOOD SUPPORT (EXPOSED). FINISH W/ PAINTED WOOD SLATS 1 1 10/28/22