HomeMy WebLinkAboutS202 - GarveyBEDROOM
MASTER
8'-0"
201
BATHROOM
MASTER
VARIES
202
CLOSET
8'-0"
202
KITCHEN
9'-0"
101
GREAT ROOM
VARIES
100
MUD ROOM
9'-0"
102
RESTROOM
9'-0"
103
CORRIDOR
9'-0"
103
S102FRAMING PLANSRoof Framing Plan
Scale: 1/4" = 1'-0"
02
S102 SHEET NO.DRAWN BY.CHECKED BY. TGJ
COPYRIGHT: Architects Forum, LLC expressly reserves the common
law copyright and other property rights in these plans. These plans
are not to be reproduced in any form or manner, nor assigned to any
third party, without first obtaining the expressed permission and
consent of Architects Forum, LLC.PROJECT NO.220510HA8555 North River Road .Suite 220 . Indianapolis . Indiana . 46240[p] 317. 842.8500 [f] 317.842.8877MICHAEL & CAROLINE'SRESIDENCE1193 HELFORD LANECARMEL, INDIANA 46032CERTIFIED BY.DATE:REVISIONS:SEPTEMBER 22, 2022PERMIT SETSEPTEMBER 22, 2022Second Level Framing Plan
Scale: 1/4" = 1'-0"
01
S102 4'-0"9'-103
4"EXISTING FRAMINGFIELD VERIFYEXISTING FRAMINGFIELD VERIFYA. ALL WORK SHALL BE PERFORMED IN STRICT COMPLIANCE
WITH ALL APPLICABLE CODES, LAWS AND ORDINANCES.
B. ALL DIMENSIONS ARE FROM FACE OF STUD, OR COLUMN
CENTERLINE. ANY DIMENSIONS NOT SHOWN OR DEEMED
QUESTIONABLE ARE TO BE VERIFIED BY ARCHITECT. DO NOT
SCALE DRAWINGS.
C. CONTACT RESPECTIVE UTILITY COMPANY FOR EXACT
LOCATION OF SERVICES PRIOR TO START OF
CONSTRUCTION. PROTECT ANY EXISTING SERVICE DURING
CONSTRUCTION.
D. SEE WALL TYPE LEGEND FOR WALL CONSTRUCTION.
E. PROVIDE FIRE TREATED WOOD BLOCKING SUPPORT AT ALL
SURFACE MOUNTED ITEMS AS REQUIRED.
F. DOOR AND FRAME NUMBERS CORRESPOND TO ROOM
NUMBERS. WHERE MORE THAN ONE DOOR OCCURS IN A
ROOM, A SUFFIX HAS BEEN ADDED (I.E. 1000A). REFERENCE
DOOR SCHEDULE.
G. CAULK ALL JUNCTURES BETWEEN DIFFERENT MATERIALS -
TYPICAL. (I.E. STOREFRONT AND GYPSUM WALLBOARD).
H. EACH CONTRACTOR SHALL PROVIDE ALL BARRICADES, ETC.
AS REQUIRED BY LAW, CODE OR ORDINANCE AND AS
OTHERWISE REQUIRED.
I. REMOVE ALL TRASH AND DEBRIS FROM THE JOB SITE DAILY.
J. PROVIDE MOISTURE RESISTANT GYPSUM WALLBOARD IN ALL
KITCHEN AREAS, TOILET ROOMS, AND WET AREAS UNLESS
INDICATED TO BE TILEBACKER WALLBOARD
PLAN NOTES
GENERAL PLAN NOTES
1 ALIGN EDGE OF NEW WALL CONSTRUCTION.
ALIGN EDGE OF NEW WALL CONSTRUCTION WITH EXISTING WALL.
NEW CASEWORK AND / OR COUNTERTOP. REFERENCE INTERIOR
ELEVATIONS, FINISH SCHEDULE, AND DETAILS.
NEW SINK FIXTURE LOCATION. PROVIDE PLUMBING CONNECTION AS
REQUIRED.
NEW WATER CLOSET FIXTURE. PROVIDE PLUMBING AS REQUIRED.
UNDER COUNTER REFRIGERATOR, PROVIDE REQUIRED ELECTRICAL
CONNECTION.
OWNER PROVIDED, CONTRACTOR INSTALLED RANGE. COORDINATE
TO PROVIDE NECESSARY CONNECTIONS.
CONTRACTOR INSTALLED OVEN LOCATION. PROVIDE DEDICATED
OUTLET WHERE NECESSARY.
GAS FIREPLACE INSERT. COORDINATE WITH MANUFACTURER TO
PROVIDE ALL NECESSARY CONNECTIONS.
CONTRACTOR-INSTALLED GRILL LOCATION. PROVIDE ALL NECESSARY
CONNECTIONS.
OWNER-FURNISHED, CONTRACTOR INSTALLED REFRIGERATOR
LOCATION. PROVIDE ALL NECESSARY CONNECTION.
DISHWASHER LOCATION. PROVIDE ALL NECESSARY CONNECTIONS.
PROVIDE GUARDRAIL AS REQUIRED. TOP OF GUARDRAIL TO BE 36"
A.F.F. MINIMUM PER BUILDING CODE.
2
WALL TYPE LEGEND
4 34"W1 2X4 WOOD STUDS AT 16" O.C. WITH 5/8"
TYPE X GYPSUM WALLBOARD EACH SIDE
AND SOUND ATTENUATION BLANKETS IN
EACH STUD CAVITY.4 34"3
4
5
6
7
8
10
9
11
12
13
PROJECT KEY MAP
PROJECT LOCATION
21'-51
2"10'-3"17'-2"6'-5"22'-111
2"
9'-103
4"6'-9"1'-8"
FLUSH MOUNT BEAM
BEAM 6: (3) 1.75" x 11.25"
MICROLLAM LVL'S
1'-3"9"
BEAM 2: (3) 1.75" x 14" MICROLLAM LVL'S
OR W8X21 STEEL BEAM
BEAM 1: (4) 1.75" x 14" MICROLLAM LVL'S
OR W8X28 STEEL BEAM
BEAM 3: (3) 1.75" x 14" MICROLLAM LVL'S
OR W8X21 STEEL BEAM
BEAM 4: (3) 2X10S BEAM 5: (3) 2X10S
10/28/22