HomeMy WebLinkAboutA003 - GarveyKITCHEN
9'-0"
101
GREAT ROOM
VARIES
100
MUD ROOM
9'-0"
102
RESTROOM
9'-0"
103
CORRIDOR
9'-0"
103
S101FOUNDATION PLANSHEET NO.DRAWN BY.CHECKED BY. TGJ
COPYRIGHT: Architects Forum, LLC expressly reserves the common
law copyright and other property rights in these plans. These plans
are not to be reproduced in any form or manner, nor assigned to any
third party, without first obtaining the expressed permission and
consent of Architects Forum, LLC.PROJECT NO.220510HA8555 North River Road .Suite 220 . Indianapolis . Indiana . 46240[p] 317. 842.8500 [f] 317.842.8877MICHAEL & CAROLINE'SRESIDENCE1193 HELFORD LANECARMEL, INDIANA 46032CERTIFIED BY.DATE:REVISIONS:SEPTEMBER 22, 2022PERMIT SETSEPTEMBER 22, 2022Foundation Plan
Scale: 1/4" = 1'-0"
01
S101
A. ALL WORK SHALL BE PERFORMED IN STRICT COMPLIANCE
WITH ALL APPLICABLE CODES, LAWS AND ORDINANCES.
B. ALL DIMENSIONS ARE FROM FACE OF STUD, OR COLUMN
CENTERLINE. ANY DIMENSIONS NOT SHOWN OR DEEMED
QUESTIONABLE ARE TO BE VERIFIED BY ARCHITECT. DO NOT
SCALE DRAWINGS.
C. CONTACT RESPECTIVE UTILITY COMPANY FOR EXACT
LOCATION OF SERVICES PRIOR TO START OF
CONSTRUCTION. PROTECT ANY EXISTING SERVICE DURING
CONSTRUCTION.
D. SEE WALL TYPE LEGEND FOR WALL CONSTRUCTION.
E. PROVIDE FIRE TREATED WOOD BLOCKING SUPPORT AT ALL
SURFACE MOUNTED ITEMS AS REQUIRED.
F. DOOR AND FRAME NUMBERS CORRESPOND TO ROOM
NUMBERS. WHERE MORE THAN ONE DOOR OCCURS IN A
ROOM, A SUFFIX HAS BEEN ADDED (I.E. 1000A). REFERENCE
DOOR SCHEDULE.
G. CAULK ALL JUNCTURES BETWEEN DIFFERENT MATERIALS -
TYPICAL. (I.E. STOREFRONT AND GYPSUM WALLBOARD).
H. EACH CONTRACTOR SHALL PROVIDE ALL BARRICADES, ETC.
AS REQUIRED BY LAW, CODE OR ORDINANCE AND AS
OTHERWISE REQUIRED.
I. REMOVE ALL TRASH AND DEBRIS FROM THE JOB SITE DAILY.
J. PROVIDE MOISTURE RESISTANT GYPSUM WALLBOARD IN ALL
KITCHEN AREAS, TOILET ROOMS, AND WET AREAS UNLESS
INDICATED TO BE TILEBACKER WALLBOARD
PLAN NOTES
GENERAL PLAN NOTES
1 ALIGN EDGE OF NEW WALL CONSTRUCTION.
ALIGN EDGE OF NEW WALL CONSTRUCTION WITH EXISTING WALL.
NEW CASEWORK AND / OR COUNTERTOP. REFERENCE INTERIOR
ELEVATIONS, FINISH SCHEDULE, AND DETAILS.
NEW SINK FIXTURE LOCATION. PROVIDE PLUMBING CONNECTION AS
REQUIRED.
NEW WATER CLOSET FIXTURE. PROVIDE PLUMBING AS REQUIRED.
UNDER COUNTER REFRIGERATOR, PROVIDE REQUIRED ELECTRICAL
CONNECTION.
OWNER PROVIDED, CONTRACTOR INSTALLED RANGE. COORDINATE
TO PROVIDE NECESSARY CONNECTIONS.
CONTRACTOR INSTALLED OVEN LOCATION. PROVIDE DEDICATED
OUTLET WHERE NECESSARY.
GAS FIREPLACE INSERT. COORDINATE WITH MANUFACTURER TO
PROVIDE ALL NECESSARY CONNECTIONS.
CONTRACTOR-INSTALLED GRILL LOCATION. PROVIDE ALL NECESSARY
CONNECTIONS.
OWNER-FURNISHED, CONTRACTOR INSTALLED REFRIGERATOR
LOCATION. PROVIDE ALL NECESSARY CONNECTION.
DISHWASHER LOCATION. PROVIDE ALL NECESSARY CONNECTIONS.
PROVIDE GUARDRAIL AS REQUIRED. TOP OF GUARDRAIL TO BE 36"
A.F.F. MINIMUM PER BUILDING CODE.
2
WALL TYPE LEGEND
4 34"W1 2X4 WOOD STUDS AT 16" O.C. WITH 5/8"
TYPE X GYPSUM WALLBOARD EACH SIDE
AND SOUND ATTENUATION BLANKETS IN
EACH STUD CAVITY.4 34"3
4
5
6
7
8
10
9
11
12
13
PROJECT KEY MAP
PROJECT LOCATION
EXISTING WALLS TO BE
DEMOLISHED
EXISTING FOUNDATION
AND STEM WALL. FIELD
VERIFY.
EXISTING FOUNDATION AND
STEM WALL. FIELD VERIFY.11"
22'-111
2"
23'-31
2"9"8'-9"11"17'-2"1'-4"
11"
51
2"6'-0"9"
11"15'-1112"24'-91
2"12'-1"9'-6"9"
4" CONCRETE SLAB WITH 6
MIL. VAPOR BARRIER OVER
4" GRANULAR FILL
4" DECORATIVE STAMPED
CONCRETE SLAB WITH 6 MIL.
VAPOR BARRIER OVER 4"
GRANULAR FILL
Typical Foundation Wall
Scale: 3/4" = 1'-0"
02
S101
GRADE, SLOP AWAY FROM BUILDING,
TYPICAL.1'-0"3'-0" BELOW GRADE MIN.2'-0"
EL. 0'-0"
FINISH FLOOR
TYPICAL FOUNDATION WALL
-POURED CONCRETE WALL (REFERENCE PLAN
FOR DIMENSIONS)
-SILL ANCHOR BOLTS @ 6'-0" O.C.
-#6 VERTICAL REINFORCEMENT @ 5" FROM
SOIL SIDE OF WALL. SPACING PER CODE.
-10" CONCRETE FOOTING
-#3 HORIZONTAL STEEL WALL REINFORCING
-LOOP WIRE REINFORCING
MORTAR NET, MASONRY
FLASHING AND WEEPS
2X6 PRESSURE-TREATED SILL PLATE
1/4" SILL GASKET
BRICK WALL CONSTRUCTION
-3-5/8" BRICK UNIT MASONRY
-AIR CAVITY
-VENEER TIES WITH SELF HEALING
TAPE AT 16" O.C. HORIZ. AND VERT.
-FLUID APPLIED MOISTURE BARRIER
-1/2" SHEATHING
-2X6 WOOD STUDS @ 16" O.C.
-R-19 BATT INSULATION
-6 MIL VAPOR BARRIER
5/8" GYP BOARD
4" CONCRETE SLAB WITH 6 MIL.
VAPOR BARRIER OVER 4"
GRANULAR FILL
GROUT SOLID BELOW GRADE
11"27'-7"4" DRAIN TILE
02
S101
10/28/22