HomeMy WebLinkAboutElectric with SmokesBEDROOM
MASTER
201
BATHROOM
MASTER
202
CLOSET
202
W.C.
204
SSS S
GAS FIREPLACE
LOCATION. PROVIDE
POWER FOR
FIREPLACE VENT AS
REQUIRED.
(VENT TO EXTERIOR)
S
C
KITCHEN
101
GREAT ROOM
100
MUD ROOM
102
RESTROOM
103
CORRIDOR
103 SSSSSS
SSSS
220HOODREFSDWGDGAS FIREPLACE
LOCATION. PROVIDE
POWER FOR
FIREPLACE VENT AS
REQUIRED.
(VENT TO EXTERIOR)
E100ELECTRICAL PLANSecond Level Electrical Plan
Scale: 1/4" = 1'-0"
02
E100 SHEET NO.DRAWN BY.CHECKED BY. TGJ
COPYRIGHT: Architects Forum, LLC expressly reserves the common
law copyright and other property rights in these plans. These plans
are not to be reproduced in any form or manner, nor assigned to any
third party, without first obtaining the expressed permission and
consent of Architects Forum, LLC.PROJECT NO.220510HA8555 North River Road .Suite 220 . Indianapolis . Indiana . 46240[p] 317. 842.8500 [f] 317.842.8877MICHAEL & CAROLINE'SRESIDENCE1193 HELFORD LANECARMEL, INDIANA 46032CERTIFIED BY.DATE:REVISIONS:OCTOBER 27, 2022PERMIT SETOCTOBER 27, 2022First Level Electrical Plan
Scale: 1/4" = 1'-0"
01
E100
GENERAL CEILING NOTES
ELECTRICAL LEGEND
A. ALL WORK SHALL BE PERFORMED IN STRICT COMPLIANCE
WITH ALL APPLICABLE CODES, LAWS AND ORDINANCES.
B. ALL ELECTRICAL PANELS ARE TO BE SIZED IN ACCORDANCE
WITH ALL STATE AND LOCAL BUILDING CODES.
C. ALL OUTLETS NOT REQUIRED TO BE GFI PROTECTED SHALL
BE ARC FAULT WITH TAMPER PROOF RECEPTACLES
D. ALL SWITCHES AND RECEPTACLES TO BE DECORA FLUSH
WHITE BY LEVITON (UNLESS NOTED OTHERWISE).
E. GENERAL CONTRACTOR TO COORDINATE ALL WORK
PERFORMED. NOTIFY ARCHITECT IN EVENT OF CONFLICT
F. ALL FIRE / SMOKE / CARBON MONOXIDE DETECTORS TO BE
WIRED IN TANDEM. IF ONE ALARM IS ACTIVATED, ALL ALARMS
ARE TO BE ACTIVATED.
G. ALL LOW VOLTAGE FIXTURES SHALL BE IC LISTED.
H. PROVIDE EXTERIOR FIXTURE STUB OUTS FOR FUTURE
LANDSCAPE LIGHTING.
I. ALL CLOSET LIGHTING SHALL MEET THE CLEARANCE
REQUIREMENTS SET FORTH IN THE NATIONAL ELECTRICAL
CODE (INCLUDING ALL LOCAL AND STATE AMENDMENTS).
J. ALL EXTERIOR LIGHTING AND FANS SHALL BE RATED FOR
EXTERIOR USE.
TYPICAL ABBREVIATIONS:
AC - ABOVE COUNTER
AUC - ABOVE UPPER CABINET
GFI - GFCI CIRCUIT
MS - MOTION SENSOR W/ PHOTO CELL
RR - RECESSED RECEPTACLE
UC - UNDER COUNTER
VP - VAPOR PROOF FIXTURE
WCR - RECEPTACLE WITHIN CABINET W/ GFI PROTECTION
WP - WEATHER PROTECTED
SWITCHING:
TV
S SINGLE POLE WALL SWITCH
S SINGLE POLE WALL SWITCH W/ DIMMER
S SINGLE POLE WALL SWITCH W/ TIMER
S 3-WAY WALL SWITCH
D
T
3
LIGHT CONTROL TOUCH PAD
GARAGE DOOR OPENER CONTROL
OUTLETS:
DUPLEX RECEPTACLE
ABOVE COUNTER LOCATED DUPLEX RECEPTACLE
WALL SWITCH CONTROLLED DUPLEX RECEPTACLE
220 VOLT RECEPTACLE220
CEILING OUTLET
FLOOR OUTLET
NOTE: ALL RECEPTACLES THAT ARE NOT REQUIRED TO BE G.F.I.
PROTECTED SHALL BE ARC FAULT & TAMPERPROOF PER N.E.C.
CODE
CAT 5 CONNECTION
CABLE T.V. CONNECTION
DISCONNECT
LIGHT FIXTURES:
RECESSED LED CEILING LIGHT FIXTURE
LED PENDANT LIGHT FIXTURE
LED WALL MOUNTED LIGHT FIXTURE
LED WALL MOUNTED FLOOD LIGHT FIXTURE
LED IN WALL MOUNTED LIGHT - LOW VOLTAGE
UNDERWATER POOL LIGHT - WALL MOUNTED
CEILING MOUNTED FAN
LED SURFACE MOUNTED LIGHT FIXTURE
MISCELLANEOUS:
JUNCTION BOX
HIGH VOLTAGE JUNCTION BOX - ROLL DOWN WINDOW
TREATMENT
HIGH VOLTAGE JUNCTION BOX - DOOR ACTUATOR
SMOKE / CARBON MONOXIDE DETECTOR: HARD WIRED,
INTERCONNECTED W/ BATTERY BACK-UP
THERMOSTAT
ELECTRICAL PANEL
HIGH VOLT. JUNCTION BOX - ROLL DOWN BUG SCREEN
GAS CONNECTION
DOOR CHIME
CEILING MOUNTED EXHAUST FAN
ALARM PANEL LOCATION
SC
J
B
W
D
A
CM
T
PROVIDE NEW SMOKE ALARM.
PROVIDE NEW CARBON MONOXIDE DETECTOR WITHIN 3'-0"
OF DOOR.
ELECTRICAL PLAN NOTES
1
2
PROJECT KEY MAP
PROJECT LOCATION
1
2
10/28/22