Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Woodfield CR201
LEFT 2010.300 CZ 0.10 Woodview BASE BUILDING CODE: . FIRE CODE: . ELECTRICAL CODE: . ENERGY CODE: . PLUMBING CODE: . MECHANICAL CODE: . MUNICIPAL CODE: . APPLICABLE CODES SHEET INDEX . . . . . . Mulhern & Kulp Engineers 300 Brookside Ave. Building 4, Suite 150 Ambler, PA 19002 215.646.8001 www.mulhernkulp.com MUNICIPALITYARCHITECT OF RECORD STRUCT. ENGINEER ZONING ORDINANCE: . USE GROUP: One & Two Family dwelling CONSTRUCTION CLASS: Unprotected Frame HEIGHT & AREA: . OTHER REQUIREMENTS: . MECH. ENGINEER BUILDING CODE ANALYSIS . . . . . . . . . . . . Sheet No.Sheet Description CZ 0.10 Cover Sheet / Project Information / Sheet Index CZ 0.20 Cover Sheet / General Notes / Abbreviations CZ 0.30 Cover Sheet / Revision Log ARCHITECTURAL DRAWINGS A0 S-1.1 Slab Utility Plan A0 SB-1.1 Slab Utility Plan w/ Masonry Wrap A0 B-1.1 Basement Foundation Plan - 9'-0" Basement A0 BB-1.1 Basement Foundation Plan w/ Masonry Wrap - 9'-0" Basement A1 0.1 Finished Basement Floor Plan A1 0.2 Finished Basement Floor Plan / Options A1 4-1.1 First Floor Plan / _ / 2x4 Exterior Walls A1 4-1.2 First Floor Plan / Options / 2x4 Exterior Walls A1 4-2.1 Second Floor Plan / _ / 2x4 Exterior Walls A1 4-2.2 Second Floor Plan / Options / 2x4 Exterior Walls A2 S.1 Building Section 1 / _ / Slab Foundation A2 S.2 Building Section 2 / _ / Slab Foundation A2 S.3 Building Section 3 / _ / Slab Foundation A2 B.1 Building Section 1 / _ / Basement Foundation A2 B.2 Building Section 2 / _ / Basement Foundation A2 B.3 Building Section 3 / _ / Basement Foundation A3 CR201 2FS.1 Craftsman 201 / 2 Car Rear Entry / Front, Side and Rear Elevations, Roof Plan and Ventilation Schedule A3 CR201 2FS.2 Craftsman 201 / 2 Car Rear Entry / Partial Slab Foundation Plan A3 CR201 2FB.2 Craftsman 201 / 2 Car Rear Entry / Partial Basement Foundation Plan A3 CR201 2FS4.3 Craftsman 201 / 2 Car Rear Entry / Partial Floor Plan - 2x4 Exterior Walls ****All Elevation Follow The A3 Sheet Numbering Used For The Craftsman 201 Elevations Above A4 CP4S.1 Covered Patio - Slab / Floor, Foundation, Utility Plans, Elevations and Roof Plan / 2x4 Exterior Walls A4 CP4I.1 Covered Patio - In-Grade Basement / Floor, Foundation, Utility Plans, Elevations and Roof Plan / 2x4 Exterior Walls A4 GX4S.1 4' Garage Extension - Slab / Floor, Foundation, Utility Plans, Elevations and Roof Plan / 2x4 Exterior Walls A4 GX4I.1 4' Garage Extension - In-Grade Basement / Floor, Foundation, Utility Plans, Elevations and Roof Plan / 2x4 Exterior Walls A4 CPGX4S.1 Covered Patio w/ 4' Garage Extension - Slab/ Floor, Foundation, Utility Plans, Elevations and Roof Plan / 2x4 Exterior Walls A4 CPGX4I.1 Covered Patio w/ 4' Garage Extension - In-Grade Basement / Floor, Foundation, Utility Plans, Elevations and Roof Plan / 2x4 Exterior Walls UTILITY DRAWINGS U0 B-1.10 Basement Utility Plan / _ / All Basement Walls U1 0.10 Finished Basement Utility Plans / _ / All Basement Walls U1 0.20 Finished Basement Utility Plans / Options / All Walls U1 0.21 Finished Basement Utility Plans / Options - Optional Lighting Package / All Walls U1 4-1.10 First Floor Utility Plan / _ / 2x4 Exterior Walls U1 4-1.11 First Floor Utility Plan / Optional Lighting Package / 2x4 Exterior Walls U1 4-1.20 First Floor Utility Plan / Options / 2x4 Exterior Walls U1 4-1.21 First Floor Utility Plan / Options - Optional Lighting Package / 2x4 Exterior Walls U1 4-2.10 Second Floor Utility Plan / _ / 2x4 Exterior Walls U1 4-2.11 Second Floor Utility Plan / Optional Lighting Package /2x4 Exterior Walls Sheet No.Sheet Description U1 4-2.20 Second Floor Utility Plan / Options / 2x4 Exterior Walls U1 4-2.21 Second Floor Utility Plan / Options - Optional Lighting Package /2x4 Exterior Walls FLOORING DRAWINGS FL 0.1 Finished Basement Flooring Plan / _ / All Basement Walls FL 0.2 Finished Basement Flooring Plan / Options / All Basement Walls FL 4-1.1 First Floor Flooring Plan / _ / 2x4 Exterior Walls FL 4-1.2 First Floor Flooring Plan / Options / 2x4 Exterior Walls FL 4-2.1 Second Floor Flooring Plan / _ / 2x4 Exterior Walls FL 4-2.2 Second Floor Flooring Plan / Options / 2x4 Exterior Walls TRIM OPTION LAYOUTS TR 4-1.1 First Floor Plan / Trim Option Layouts / 2x4 Exterior Walls TR 4-2.1 Second Floor Plan / Trim Option Layouts / 2x4 Exterior Walls ARCHITECTURAL DETAILS AD SHEETS Typical Architectural Details STRUCTURAL DRAWINGS S-0 Sheets Structural Notes S-1 Sheets Foundation & First Floor Framing Plans S-2 Sheets Second Floor Framing Plans S-3 Sheets Roof Framing Plans S-4 Sheets Framing Details S0-1 Sheets Plan Options S0-2 Sheets Plan Options S0-3 Sheets Deck Framing Plans STRUCTURAL DETAILS SD Sheets Structural Details NORTH AREA 1900 EAST GOLF ROAD - SUITE 300 - SCHAUMBURG, IL 60173 LEFT 2010.300 ATTIC VENT SCHEDULE CR201 2-CAR REAR ENTRY ROOF AREA 'A' ROOF AREA 'B' ATTIC AREA (SF)1898 176 TOTAL NET FREE VENTED AREA REQ.911 IN2 84 IN2 LOW - REQUIRED (*)456 IN2 42 IN2 LOW - ACTUAL w/ EAVE VENTS (**) 476 IN2 17 EAVE VENTS 56 IN2 2 EAVE VENTS LOW - ACTUAL w/ CONTINUOUS VENTED SOFFITS (**) 460 IN2 46 LINEAR FEET 50 IN2 5 LINEAR FEET HIGH - REQUIRED (*)456 IN2 42 IN2 HIGH - ACTUAL w/ POT VENTS (***) 488 IN2 8 VENTS 61 IN2 1 VENTS HIGH - ACTUAL w/ CONT. RIDGE VENTS (***) 468 IN2 26 LF 54 IN2 3 LF * REQUIRED NET FREE VENTED AREA IS CALCULATED BY MULTIPLYING THE ATTIC AREA (FT 2) BY 1/300 AND THEN MULTIPLYING BY 144 (CONVERTING FT 2 TO IN 2). 50% OF TOTAL NET FREE VENTED AREA IS REQUIRED NEAR THE RIDGE (HIGH) AND 50% IS REQUIRED AT THE SOFFIT (LOW). WHEN BOTH (HIGH) & (LOW) AREN'T PROVIDED, THE REQ'D NET FREE AREA IS 1/150 OF THE ACTUAL AREA INSTEAD. ** ACTUAL NET FREE VENTED SOFFIT AREA IS CALCULATED BY DIVIDING THE REQUIRED (LOW) AREA BY THE MFRS STATED ACTUAL VENTED NET FREE AREA PER VENT: LOW OPT 1: EAVE VENTS = 28.0 IN 2/VENT (OR) LOW OPT 2: CONT. VENTED SOFFITS = 10.0 IN 2/LINEAR FT *** ACTUAL NET FREE VENTED RIDGE AREA IS CALCULATED BY DIVIDING THE REQUIRED (HIGH) AREA BY THE MFRS STATED ACTUAL VENTED NET AREA PER VENT: HIGH OPT 1: POT ROOF VENTS = 61.0 IN 2/VENT (OR) HIGH OPT 2: CONT. RIDGE VENTS = 18.0 IN 2/LINEAR FT Board & Batten Siding Shake Siding Horizontal Siding Masonry Wainscoting Architectural Style: CRAFTSMANCR 201 Brick Wrap Wainscoting Brick Wrap Wainscoting Brick Wrap Wainscoting 3060 3060 3053 3053 2040 3053 3053 3053 3053 3053 4020 3060 3060 3053 3060 3060 3060 3060 3053 3060 3060 3060 2040 2040 30533053 LEFT 2010.300 PORCH FLEX FOYERDINING PR LAUNDRY SQUARE FOOTAGES BASE HOUSE - HEATED FIRST FLOOR 1609 SECOND FLOOR 1607 TOTAL BASE HEATED 3216 BASE HOUSE - UNDER ROOF GARAGE - 2 CAR REAR ENTRY 417 TOTAL BASE UNDER ROOF 3633 OPTIONS BASEMENT 1609 COVERED PATIO 173 4' GARAGE EXTENSION 83 LIGHT & VENT SCHEDULE ROOM NAME AREA (SF) LIGHT 8% VENT 4%MECH (CFM) REQ ACT REQ ACT REQ ACT KITCHEN / CAFE / GATHERING 719.6 57.6 68.5 28.8 29.5 --- --- LAUNDRY 73.7 5.9 --- 2.9 --- 76.6 80 DINING ROOM 147 11.8 27.4 5.9 11.8 --- --- FLEX 126.7 10.1 27.4 5.1 11.8 --- --- POWDER ROOM 39.1 3.1 --- 1.6 --- 40.7 60 BEDROOM 2 159.2 12.7 23.4 6.4 11.8 --- --- BEDROOM 3 164.8 13.2 23.4 6.6 11.8 --- --- BEDROOM 4 134.9 10.8 11.7 5.4 5.9 --- --- BEDROOM 6 115.90 9.3 27.4 4.6 11.8 --- --- LOFT 188.4 15.1 23.4 7.5 11.8 --- --- O. SUITE 230.5 18.4 41.1 9.2 17.7 --- --- O. BATH 110.1 8.8 --- 4.4 --- 114.5 140 BATH 2 57.4 4.6 --- 2.3 --- 59.7 60 BATH 3 41.7 3.3 ---1.7 --- 43.4 60 BATH 6 46.09 3.7 2.0 1.8 --- 47.9 60 BEDROOM 7 161.6 12.9 11.9 6.5 6.5 --- --- BATH 7 44.8 --- --- --- --- 52.4 60 MEDIA ROOM 231 --- --- --- --- 270.3 260 ELEVATION CR201 ADDITIONAL 1ST FLOOR - HEATED 0 TOTAL 1ST FLOOR 1609 ADDITIONAL 2ND FLOOR - HEATED 12 TOTAL 2ND FLOOR 1619 TOTAL ELEV. HEATED 3228 ADDITIONAL GARAGE - 2 CAR REAR 0 TOTAL GARAGE 417 FRONT PORCH 129 TOTAL ELEV. FOOTPRINT 3774 BEDROOM 3 BATH 2 BEDROOM 2 WIC