Loading...
HomeMy WebLinkAbout06050176 Site Plan Grou .Glna SLJrv'~yc>rs 3 West Carmel Drive, Carmel, IN 46032 317.844.3333 F 317.844.3383 . VIIWW. seag rou pile. eom 1-IIS PLOT PLAN WAS 'REPARED BASED ON ,FORMA TION TAKEN FROM :ECORD PLATS. SUBDIVISION 'LANS. RECORD DRA\I1NGS ,NO PLANS PROVIDED BY :L1ENT. IT IS THE :ESPDNSIBILlTY OF THE :ONTRACTOR TO VERIFY SITE :ONDIllONS PRIOR TO :DNSTRUCTION AND NOTIFY HE SEA GROUP LLC and 'RENWICK OF ANY IISCREPANCIES. OCATION OF UTILITY A TERALS ON PLOT PLAN HE GENERAL LOCATIONS ER PLAN AND SHOULD BE ERIFIED IN THE FIELD. 'OTE: :UILDER TO ENSURE POSITIVE LOW AWAY FROM TRUCTURE. OTE: UMP TO BE PLACED BY :UILDER AS NEEDED. LOCATION OF UTILITIES ON PLOT PLAN ARE GENERAL LOCATIONS PER PLAN AND SHOULD BE VERIFIED IN THE FIELD. GRANULAR BACKFILL SUGGESTED UNDER DRIVEWAY AT SANITARY SEWER LATERAL TRENCH. WATER LINE TRENCH AND ANY OTHER EXCAVATED AREAS. (IF SITUATION OCCURS) MINIMUM SETBACKS Min Side - 5 Feet or 8% Lot width @ B L (96 Feet) Min Rear 20 Feet AQo - 18% of lot width @ B L (21 7 Feet) ,,~ ~~ ~~ ~ 1& ~ ~ :;: <&- "0' 0", ~ ~~ ~ ~ ~, "~ ~"" 100.01 PROPOSED GRADE PER PLAN - GROUND WAlER FLOW ----- SANITARY SEWER LINE ----- STORM SEWER LINE -WIlt-wTfI- WATER LINE _______u__________ EASEMENT LINE - - - - - BUILlDING SETBACK UNE NOTE: BUILDER IS TO GRADE SIDEYARD SWALE TO GRADES SHOWN ON THIS PLAN. IF BUILDER IS UNABLE TO ACHIEVE POSIllVEDRAINAGE AWAY FROM PROPOSED STRUCTURE. THE ENGINEER SHALL BE CONTACTED. BUILDER IS NOT TO DEVIATE FROM GRADES SHOWN ON THIS PLAN \I1THOUT THE CONSENT OF BOTH THE ENGINEER AND BREN\I1CK. .3~ r81is:6l --....::: 22.00' I I I I I Iii I /g" ~ / Q "I 12 .C) I !2 I I / / !if. //~ 1//1 A 1 / 'lYe} / //,~~ II I~O "I . / "Il-'" / I ~ / ./~I /, ,0 1/ I //h / //~ ()O 1/ I;;<~/ G' 1 /A .::; 1 1 1 1 / //;1 I~ 1 1 /~r\..~ II 1/1'0 / 1 1 '" 1 . ~.;t~ ;' 'Or 1 r 1 1 1 /.~ W ~: (SECONDARY AREAS NESTCLAY) MAX. HEIGHT: ON LOTS 100' AND :GER (TO EVE LINE) 30' LESS THAN 100' MAX. IERAGE: 50% 'E: THE INFORMATION , THE ELEVATION 'ERENCE BETWEEN THE ~ARY FINISHED FLOOR VA TION TO THE TOP OF ;EMENT WALL AND TO BASEMENT FINISHED OR WAS PROVIDED BY BUILDER. ~ OF WATER TAP TO BE [ORED TO ITS' ORIGINAL DillON PRIOR TO STRUCTION. SERVICE LATERAL SSINGS AT CURB ARE ~PED SS- SANITARY oR SD- SUBSURFACE N W= WATER CONC. DRIVE ~ GARAGE it. m-S96.0 NOTE: THE FINISHED FLOOR ELEVATIONS AND PAD GRADES DEPICTED ON THIS PLOT PLAN IS OPEN FOR REVIEW BY BREN\I1CK DEVELOPMENT. THE BUILDER IS CAUTIONED THAT SAID INFORMATION IS SUBJECT TO CHANGE. DENOTES LOCATION PER CONSTRUCTION PLAN DRA\I1NGS. CONFIRM BEFORE CONSTRUCTION OF 6" SANITARY LATERAL AND WATER SERVICE LINE. 30.0' ~ ~ NOTE: (PRIMARY AREAS - WESTCLAY) MAX. HEIGHT: 30' BUILD-UP LINE: 2 STORIES MAX. COVERAGE: 50% NOTE: PAD ELEVATION SHOIl1< IS PER PLANS AND IS NOT THE AS-BUILT ELEVATION. SILT FENCE TO BE USED WHERE NEEDED TO KEEP MUD OFF OF STREETS AND OUT OF STORM SEWERS. AREA OF WATER TAP TO BE BACKFILLED \11TH GRANULAR MATERIAL TO \I1THIN 10" OF TOP OF CURB. NOTE: CONCRETE APRON TO MA TCH EXISTING ALLEY EDGE OF PAVEMENT ELEVATION ALL MUD IN STREETS FROM TRUCKS LEAVING LOT TO BE CLEANED AT THE END OF EACH DAY. " , ~ ,~ \ , ~~ .?.j.on 'o~ ~<" % ,1'0."" ~ LOT# 19.507 , ~ , ~, ~ CJI 20.50' ~. i:~ , PROPOSED fRl.l &: I.lSY RESIDENCE FFE-898.5 BSMT m-888.5:l:: ~ " ~. --- , , ~","1II""'111 perty Description: ~''C~~!9...'!.'s''''~ ~.;;;. ....{.GISTt.\'l'..:ti( '" '< .' 'l' ()". Number 824 in the Village of Westclay, Section 10002, an Addition in Hamilton ::s." N . ( :::Cl:: ! 0 "' unty, Indiana, as per plat thereof recorded as Instrument Number 200400075938 -co: . ~ ~ * i LS20200083 i nd in the Office of the Recorder of Hamilton County, Indiana - . . ~ \\ STATE OF :i ~ ('. .~ Prepared For: ~ ~"'" INOIAIl~,""() :i'. '. .' , ,; ~ 1/10 .......... <t.'\ , PLOT PLAN Jacoby Homes """/, SUR'l ~"", "'II"IIII""\'~ ,cole: 1"=30' I Drown by: DJR Residence ~$ lote: Moy 8. 2006 IRevised: 1950 Finchley Road