HomeMy WebLinkAbout06050176 Site Plan
Grou
.Glna SLJrv'~yc>rs
3 West Carmel Drive, Carmel, IN 46032
317.844.3333 F 317.844.3383
.
VIIWW. seag rou pile. eom
1-IIS PLOT PLAN WAS
'REPARED BASED ON
,FORMA TION TAKEN FROM
:ECORD PLATS. SUBDIVISION
'LANS. RECORD DRA\I1NGS
,NO PLANS PROVIDED BY
:L1ENT. IT IS THE
:ESPDNSIBILlTY OF THE
:ONTRACTOR TO VERIFY SITE
:ONDIllONS PRIOR TO
:DNSTRUCTION AND NOTIFY
HE SEA GROUP LLC and
'RENWICK OF ANY
IISCREPANCIES.
OCATION OF UTILITY
A TERALS ON PLOT PLAN
HE GENERAL LOCATIONS
ER PLAN AND SHOULD BE
ERIFIED IN THE FIELD.
'OTE:
:UILDER TO ENSURE POSITIVE
LOW AWAY FROM
TRUCTURE.
OTE:
UMP TO BE PLACED BY
:UILDER AS NEEDED.
LOCATION OF UTILITIES ON
PLOT PLAN ARE GENERAL
LOCATIONS PER PLAN AND
SHOULD BE VERIFIED IN THE
FIELD.
GRANULAR BACKFILL
SUGGESTED UNDER
DRIVEWAY AT SANITARY
SEWER LATERAL TRENCH.
WATER LINE TRENCH AND
ANY OTHER EXCAVATED
AREAS. (IF SITUATION
OCCURS)
MINIMUM SETBACKS
Min Side - 5 Feet or 8% Lot width @ B L (96 Feet)
Min Rear 20 Feet
AQo - 18% of lot width @ B L (21 7 Feet)
,,~
~~
~~
~
1& ~
~ :;:
<&-
"0'
0", ~
~~ ~
~
~,
"~
~""
100.01 PROPOSED GRADE PER PLAN
- GROUND WAlER FLOW
----- SANITARY SEWER LINE
----- STORM SEWER LINE
-WIlt-wTfI- WATER LINE
_______u__________ EASEMENT LINE
- - - - - BUILlDING SETBACK UNE
NOTE: BUILDER IS TO
GRADE SIDEYARD SWALE TO
GRADES SHOWN ON THIS
PLAN. IF BUILDER IS
UNABLE TO ACHIEVE
POSIllVEDRAINAGE AWAY
FROM PROPOSED
STRUCTURE. THE ENGINEER
SHALL BE CONTACTED.
BUILDER IS NOT TO DEVIATE
FROM GRADES SHOWN ON
THIS PLAN \I1THOUT THE
CONSENT OF BOTH THE
ENGINEER AND BREN\I1CK.
.3~
r81is:6l
--....::: 22.00'
I
I
I
I
I Iii I
/g" ~ /
Q "I
12 .C) I
!2 I
I
/ / !if.
//~
1//1 A 1
/ 'lYe} /
//,~~ II
I~O "I
. / "Il-'" /
I ~ /
./~I /, ,0 1/
I //h /
//~ ()O 1/
I;;<~/ G' 1
/A .::; 1
1 1
1 /
//;1
I~
1 1
/~r\..~ II
1/1'0 /
1 1
'" 1 .
~.;t~ ;'
'Or 1
r 1
1
1
/.~
W
~: (SECONDARY AREAS
NESTCLAY) MAX. HEIGHT:
ON LOTS 100' AND
:GER (TO EVE LINE) 30'
LESS THAN 100' MAX.
IERAGE: 50%
'E: THE INFORMATION
, THE ELEVATION
'ERENCE BETWEEN THE
~ARY FINISHED FLOOR
VA TION TO THE TOP OF
;EMENT WALL AND TO
BASEMENT FINISHED
OR WAS PROVIDED BY
BUILDER.
~ OF WATER TAP TO BE
[ORED TO ITS' ORIGINAL
DillON PRIOR TO
STRUCTION.
SERVICE LATERAL
SSINGS AT CURB ARE
~PED SS- SANITARY
oR SD- SUBSURFACE
N W= WATER
CONC.
DRIVE
~ GARAGE
it. m-S96.0
NOTE: THE FINISHED
FLOOR ELEVATIONS AND
PAD GRADES DEPICTED ON
THIS PLOT PLAN IS OPEN
FOR REVIEW BY BREN\I1CK
DEVELOPMENT. THE BUILDER
IS CAUTIONED THAT SAID
INFORMATION IS SUBJECT
TO CHANGE.
DENOTES LOCATION PER
CONSTRUCTION PLAN
DRA\I1NGS. CONFIRM BEFORE
CONSTRUCTION OF 6"
SANITARY LATERAL AND
WATER SERVICE LINE.
30.0'
~
~
NOTE: (PRIMARY AREAS -
WESTCLAY) MAX. HEIGHT:
30' BUILD-UP LINE: 2
STORIES MAX. COVERAGE:
50%
NOTE: PAD ELEVATION
SHOIl1< IS PER PLANS AND
IS NOT THE AS-BUILT
ELEVATION.
SILT FENCE TO BE USED
WHERE NEEDED TO KEEP
MUD OFF OF STREETS AND
OUT OF STORM SEWERS.
AREA OF WATER TAP TO BE
BACKFILLED \11TH GRANULAR
MATERIAL TO \I1THIN 10" OF
TOP OF CURB.
NOTE: CONCRETE APRON TO
MA TCH EXISTING ALLEY
EDGE OF PAVEMENT
ELEVATION
ALL MUD IN STREETS FROM
TRUCKS LEAVING LOT TO BE
CLEANED AT THE END OF
EACH DAY.
"
,
~
,~
\
,
~~
.?.j.on
'o~
~<"
% ,1'0.""
~
LOT#
19.507
,
~
,
~,
~
CJI 20.50' ~.
i:~
,
PROPOSED
fRl.l &: I.lSY
RESIDENCE
FFE-898.5
BSMT
m-888.5:l::
~
"
~.
---
,
,
~","1II""'111
perty Description: ~''C~~!9...'!.'s''''~
~.;;;. ....{.GISTt.\'l'..:ti(
'" '< .' 'l' ()".
Number 824 in the Village of Westclay, Section 10002, an Addition in Hamilton ::s." N . (
:::Cl:: ! 0 "'
unty, Indiana, as per plat thereof recorded as Instrument Number 200400075938 -co: . ~
~ * i LS20200083 i
nd in the Office of the Recorder of Hamilton County, Indiana - . .
~ \\ STATE OF :i
~ ('. .~
Prepared For: ~ ~"'" INOIAIl~,""()
:i'. '. .' ,
,; ~ 1/10 .......... <t.'\ ,
PLOT PLAN Jacoby Homes """/, SUR'l ~"",
"'II"IIII""\'~
,cole: 1"=30' I Drown by: DJR Residence ~$
lote: Moy 8. 2006 IRevised: 1950 Finchley Road