Loading...
HomeMy WebLinkAbout06050184 Site Plan '~~ Schneider This Plot Plan Prepared For: Pulte Homes Townhomes at CuRford Instrument' 200500080749 SEe 36, TIaN. RJE HamDton County, Cloy Twp. City ofCormel-- .-. Block 7 Prepared-Dale: 05/15/2006 : By: ..AMA The Schneider CoI'JlOI'll.UOD 8901 Otis Avenue HiItorlc Porl Hanison bldlanapolll, Indlana <621'-[03' 31'-626-7100 317-82(1-7200 PAX Pulle Homes Finished Floor Elevation Information PAD=850.38 FFE=850.80 , ..- I i!~ I 4.5' !I\ il ~ J oJ I IW : ') -' I:z: : j- 1<( <( ::> l---l w ::> I a::: 10 <( :::> n I 0::: :z: <(~ I> :::;: I 0::: 0 1<( u I::r: '" I '" I on I ~ 10 I. ~I ~ I' V> 24.~ ACCESS [91T. ~~~~ "" ~c:')~ ~.. ~ ~ ~ ", ~i!O ~~ <3 :!\ ,..; "'> N I'l~ ~ '" to.5' 74.25' WAU< 00 - ~~~\< 10.5' "" ~= "':: ~ ~ '" ", ~ ,..; !Q 5< ~. N 74.25' m~ili~ - A'.... t; ~1ij~ 51 ~ llt 42.6T ;:;r m,,, .. ' i!~ I "' ~ 00 25.1 ~o &1 ~ ~~ ~* I ~O\ .~~ AU< ~ ~! iJl.~ I'l~ 1'1 "" o oi N ~ -..... Landlcape Architecture GIS.IJS GeoI..,- Note: This drawing is based on construction pions or record drawings, and is not based upon (] field survey. The Schneider Corporation does not warrant the accuracy or sufficiency of this information. Contractors should verify existing conditions prior to any construction. Any discrepancy found on this drawing should be reported to The Schneider Corporation immediately; failing to do so results in the contractors assumption of all liability. 00 ,..; Plot Plan leqend [QQ[Q] Proposed Grades 000.0 Existing Grades __ 000.0-- Contour Grade * Approx. lateral location _ . - Sanitary Sewer Lines _11'_ Storm Sewer Lines --'W -Water-Service.Unes - - - - - - - Sub- Surface Drain Lines . Manhole (Sonitory or Stonn) . Beehive Inlet (Stonn) IIIB Curb Inlet (Storm) D End Section (Storm) .... ~re Hydrant _ 0 g 0 - 0 g 0 - Flow Line of swale - - Building Une (BL ! BSl) - - - - - - - Easement Line BLOCK 7 ij ,~ Q~Q ij Assumed North Scale: 1" = 30' Note: Sanitary Sewer Top of Casting Information Upstream Manhole, TC= 849.70 Downstream Manhole, TC=849.70 per plan. PAlIi 849.9 1.9' NOTE: IN THE RESIDENTIAL DISTRICTS LIMITING HEIGHT TO TWENTY-FIVE (25) FEET, A DWELLING MAY BE INCREASED IN HEIGHT TO THIRTY-FIVE (35) FEET PROVIDED THE SIDE AND REAR YARDS ARE INCREASED AN ADDITIONAL FOOT FOR EACH FOOT SUCH STRUCTURE EXCEEDS TWENTY-FIVE (25) FEET IN HEIGHT. PER CARMEL ZONING ORDINANCE 26.'.1. 4().6T ~"'ilit:l 1::<n<Q N .."-",,,= c!::2 -...Ji?D o!, !Q g 42.67' 74.25 10.5' b o <ci N ilI~;<tl ~..~~ '" ~ nC 0 2li ~ f\"I~ "'" . 4267' 74.25' 10.5' "" ", ...; N z '" . o 4: 1 SLOPE 0'. ~: \ 51-OPt. TYPICAL SWALE SECTION o Oz ;1iil'25 00 z II ~o L ~Cn0Jr ~o -oJ LOT # - ADDRESS 701 - 11755 Harvard Lane 702 11751 Harvard lane 703 11747 Harvard Lane 704 11743 Harvard Lane 705 11739 Harvard Lane 706 11735 Harvard Lane '" 26.00' 2, to.S' 24.15 SL\Il FLOOD HAZARD STATEMENT CERTlFICA TlON ' \\\\\\\\\lilllllll/lilllll' ~\\\'\ L I'lij~ # ,S 'C,L> ~ if) ~'\ ....'........ /T~/~ ;:;,' ~....c;. ,5 TE:/T.;:.... ~ A~ ;::$ .'/. N .... "^'.:::::: ~c--.. ."Q;-v 0 O"";o~ g ~/ . \ % 2: : : :=: ~ \ 50303 ) ~ % ..... STATE OF .f ~ ~<"'I \l'-....<CLfg ~ 4A>.IvOlA't.\ .,.~~",,~ ~i!!! "'S'U'R~'\\~~ '////111/1/11111\\\\\\\\\\'\ '0'-l.~ 2510 mER ~FRId &:...: ....RESlDENr Note: The contractor is to maintain a minimum distance of ten feet (10') between the sanitary sewer and water line laterals. FLOOD HAZARD STATEMENT: The accuracy of any flood hazard data shown on this report is subject to map scale uncertainty and to any other uncertainty in location or elevation on the referenced flood insurance rate mop (FIRM). All of the within described land DOES NOT UE within that special flood hazard zone A as said land plots by scale on flood insurance rate map' 18057C0209F for Hamilton County, Indiana (map effective dote February 19, 2003).