HomeMy WebLinkAbout06050184 Site Plan
'~~
Schneider
This Plot Plan Prepared For: Pulte Homes
Townhomes at CuRford
Instrument' 200500080749
SEe 36, TIaN. RJE
HamDton County, Cloy Twp.
City ofCormel-- .-.
Block 7
Prepared-Dale: 05/15/2006 : By: ..AMA
The Schneider CoI'JlOI'll.UOD
8901 Otis Avenue
HiItorlc Porl Hanison
bldlanapolll, Indlana <621'-[03'
31'-626-7100
317-82(1-7200 PAX
Pulle Homes
Finished Floor Elevation Information
PAD=850.38
FFE=850.80
, ..-
I i!~
I 4.5'
!I\
il ~
J
oJ I
IW :
') -'
I:z: :
j- 1<( <(
::> l---l w
::> I a:::
10 <(
:::>
n I 0::: :z:
<(~
I> :::;:
I 0::: 0
1<( u
I::r: '"
I '"
I on
I
~ 10
I.
~I
~ I'
V>
24.~
ACCESS
[91T.
~~~~ ""
~c:')~ ~.. ~ ~ ~ ",
~i!O ~~ <3 :!\ ,..;
"'> N
I'l~ ~ '" to.5'
74.25'
WAU< 00 -
~~~\< 10.5' ""
~= "':: ~ ~
'" ",
~ ,..;
!Q 5< ~. N
74.25'
m~ili~ -
A'.... t;
~1ij~ 51 ~ llt
42.6T
;:;r m,,,
.. '
i!~ I
"'
~
00
25.1
~o &1 ~ ~~
~* I ~O\ .~~
AU<
~ ~!
iJl.~
I'l~
1'1
""
o
oi
N
~
-.....
Landlcape Architecture
GIS.IJS
GeoI..,-
Note:
This drawing is based on construction pions or record drawings,
and is not based upon (] field survey. The Schneider Corporation
does not warrant the accuracy or sufficiency of this information.
Contractors should verify existing conditions prior to any
construction. Any discrepancy found on this drawing should be
reported to The Schneider Corporation immediately; failing to do
so results in the contractors assumption of all liability.
00
,..;
Plot Plan leqend
[QQ[Q] Proposed Grades
000.0 Existing Grades
__ 000.0-- Contour Grade
* Approx. lateral location
_ . - Sanitary Sewer Lines
_11'_ Storm Sewer Lines
--'W -Water-Service.Unes
- - - - - - - Sub- Surface Drain Lines
. Manhole (Sonitory or Stonn)
. Beehive Inlet (Stonn)
IIIB Curb Inlet (Storm)
D End Section (Storm)
.... ~re Hydrant
_ 0 g 0 - 0 g 0 - Flow Line of swale
- - Building Une (BL ! BSl)
- - - - - - - Easement Line
BLOCK 7
ij
,~
Q~Q
ij
Assumed North
Scale: 1" = 30'
Note: Sanitary Sewer
Top of Casting Information
Upstream Manhole, TC= 849.70
Downstream Manhole, TC=849.70
per plan.
PAlIi
849.9
1.9'
NOTE:
IN THE RESIDENTIAL DISTRICTS
LIMITING HEIGHT TO
TWENTY-FIVE (25) FEET, A
DWELLING MAY BE INCREASED
IN HEIGHT TO THIRTY-FIVE (35)
FEET PROVIDED THE SIDE AND
REAR YARDS ARE INCREASED
AN ADDITIONAL FOOT FOR EACH
FOOT SUCH STRUCTURE
EXCEEDS TWENTY-FIVE (25)
FEET IN HEIGHT. PER CARMEL
ZONING ORDINANCE 26.'.1.
4().6T
~"'ilit:l
1::<n<Q N
.."-",,,=
c!::2 -...Ji?D o!,
!Q g
42.67' 74.25 10.5'
b
o
<ci
N
ilI~;<tl
~..~~ '" ~
nC 0 2li ~
f\"I~ "'" .
4267' 74.25'
10.5'
""
",
...;
N
z
'"
.
o
4: 1 SLOPE 0'. ~: \ 51-OPt.
TYPICAL SWALE SECTION
o
Oz
;1iil'25
00 z
II ~o L
~Cn0Jr
~o
-oJ
LOT # - ADDRESS
701 - 11755 Harvard Lane
702 11751 Harvard lane
703 11747 Harvard Lane
704 11743 Harvard Lane
705 11739 Harvard Lane
706 11735 Harvard Lane
'"
26.00'
2,
to.S'
24.15
SL\Il
FLOOD HAZARD STATEMENT
CERTlFICA TlON '
\\\\\\\\\lilllllll/lilllll'
~\\\'\ L I'lij~
# ,S 'C,L> ~
if) ~'\ ....'........ /T~/~
;:;,' ~....c;. ,5 TE:/T.;:.... ~ A~
;::$ .'/. N .... "^'.::::::
~c--.. ."Q;-v 0 O"";o~
g ~/ . \ %
2: : : :=:
~ \ 50303 ) ~
% ..... STATE OF .f ~
~<"'I \l'-....<CLfg
~ 4A>.IvOlA't.\ .,.~~",,~
~i!!! "'S'U'R~'\\~~
'////111/1/11111\\\\\\\\\\'\
'0'-l.~
2510
mER
~FRId &:...:
....RESlDENr
Note: The contractor is to maintain a
minimum distance of ten feet (10')
between the sanitary sewer and water
line laterals.
FLOOD HAZARD STATEMENT: The accuracy of any flood hazard data shown on this report is subject to
map scale uncertainty and to any other uncertainty in location or elevation on the referenced flood
insurance rate mop (FIRM). All of the within described land DOES NOT UE within that special flood hazard
zone A as said land plots by scale on flood insurance rate map' 18057C0209F for Hamilton County,
Indiana (map effective dote February 19, 2003).