HomeMy WebLinkAbout06050197 Site Plan
NOTE: IN THE RESIDENTIAl.
DISTRICTS LIMITING HEIGHT TO
TWENTY-FIVE (25) FEET. A
DWEl.L1NG MAYBE INCREASED IN
HEIGHT TO THIRTY-FIVE (35) FEET
PROVIDED THE SIDE AND REAR
YARDS ARE INCREASED AN
ADDITIONAL FOOT FOR EACH FOOT
SUCH STRUCTURE EXCEEDS
TWENTY-FIVE (25) FEET IN HEIGHT,
PER CARMEl. ZONING ORDINANCE
Z6,1.1.
The Schneider Corporation
8901 Otis Avenue
Hisloric Fort Harrison
Indianapolis, Indiana 46216-1037
317-826-7100
317-826-7200 FAX
Enginkering
Surveying
Landscape Archilecture
GIS.LIS
Geology
Schneider
NOTE: THE BASEMENT ELEVATION DEP.JCTED HEREON HAS
BEEN DETERMINED AND BASED UPON THE PAD GRADES AND
OR CONTOURS TAKEN fROM THE CONSTRUCTION PLANS reR
THE SUBDIVISION. UNLESS STATED. NO INfORMATION ABOUT
fLUCtuATING WATE"R TABLES, SOIL CONDITJDN5 OR SOil
TYPES WITHIN THE BUILDING AREA HAS BEEN PROVIDED OR
STATEO ON SAID PLANS. IT IS RECOMMENDED THAT
BASEMENT F'INISHED FLOOR (LEVAnONS BEAT LEAST (2)
FEET ABOVE THE NORMAL -POOL [LEVA TlON' OF ANY
ADJOINING 80DIES OF WATER UNLESS A STUDY OF fACTS
REVEALS OTHERWISE. IF DURING THE EXCAVATION PROCESS,
ANY GROUNDWATER,IS WITNESSED, THE SCHNEIDER
CORPORA nON SHoULD BE NOTIFIED IMMEDIA TEL Y. THE
BASEMENT ELEVATION SHOULO BE RAISED 2' ABOVE THE
CROUNDWA TER LEVEL AND ADDITIONAL CONSTRUCTION
TECHNIQUES SHOULD BE INCORPQRA TED TO ALLEVIATE
. FUTURE PROBLEMS.
NOTE: THIS DRAWING IS BASED ON
CONSTRUCTION PLANS OR RECORD
DRAWINGS AND IS NOT BASED UPON A
FIELD SURVEY. THE SCHNEIDER CORP.
DOES NOT WARRANT THE ACCuRACY OR
SUFFlCIENCy.aF THIS INFORMATION. THE
CONTRACTOR SHOULD VERIFY _EXISTING
CONDITIONS PRIOR TO' ANY
CONSTRUCTION. ANY DISCREPANCY
F"OUND UPON THIS DRAWING SHOULD BE
REPORTED' TO THE SCHNEIDER
CORPORATION IMMEDIATELY: FAILURE TO
DO SO WILL RESULT IN' THE CONTRACTORS
ASSUMPTION OF LIABILITY.
:i
"
b
I
\s~ciPt
.:
"-
TYPICAL SWALE SECTION
. 0
-J~=
o
ASSUMED NORTH
SCALE 1" ~ 30'
~""-
~
~
~
,
~
15
'"
."l
COMMON AREA "c"
TP,[.
,
.~
85,00'
-ar ar
,
I
,
,
I
I
'd
,,,,
,'"
I
815.0
LOT # 6
12,664 SF
,
* APPROXIMA IE LOCA liON
CONFIRM BEFORE CONSIRUCTION
6- SANIIARY lAltRAl &: ~
WATER LATERAl
i ,
~ w
ill >
1- :s:
0:::........... ~
00::: ~
f
<t:
0:::"
=:JO
~ <t:LI)
~ ,
~
1000.01 PRQPOSEO GRADE
.;~
"0
C)
d
'"
NOTE:
CONTRACTOR TO MAINTAIN
A 10 FOOT SEPARATION
BETWEEN THE SANITARY
LA TER,AL & WATER LATERAL
5,0'
1817.61
CONe
"""
NOTE; GARACE F.F.E. IS
I PROPOSED TO BE 2.". ABOVE
CURB A T DRIVE PER PLAN.
..J
~~ ~ r
~\lt
~ ... ~~~-
'-.....WAfER liNE
,
16.0'
,
!C."." T
PER~ SAH.SE
-'---'-' .
. I 816.9
..
TC..816.70
~~
.
15'O.U.4:S.E.
a
a
1-
....
""'"
s.s.o.
ElEV...816.4
PERPlJ,N
ROll""
HAN.CAP
"""
..
I
DRIVE ' .
~~~
LAURA
50'
VISTA
R/W
-~
~
~
~
NOTE:
THE WITHIN PLOT PLAN WAS PREPARED AT THE CLIENT'S
REQUEST WITHOUT BENEFIT OF A RECORD PLAT, THE
CONTRACTOR AND/OR BUILDER HAS BEEN CAUTIONED
. THAT THE DEPICTED LINES SHOWN HEREON ARE SUBJECT
TO CHANGE,
PLOT PLAN
STEVE
PREPARED FOR:
~,
SCHUTZ BUILDER, IN.C::
PLOT PLAN LOT #6
VISTA
# 200400014732
#.3; SLIDE 360
LAURA VISTA DRIVE
LAURA
INSTR,
P,C.
14!>41
.
03/01/04 DJR