Loading...
HomeMy WebLinkAbout06060035 Site Plan ... Schneider i' The Schneider Corporation B001 Otis Avenue Historic Fort Harri!on lndianapolil, lndilU111 46216-1037 317-826-7100 317-826-7200 FAX Engineering Surveying Landscape Archllecture GLS. US Gt.()lIlC Note: This drawing is based on construction plans or record drawings, and is not based upon 0 field survey. The Schneider Corporation does not warrant the accuracy or sufficiency of this information. Contractors should verify existing conditions prior to any construction. Any discrepancy found on this drawing should be reported to The Schneider Corporation immediately; foiling to do so results in the contractors assumption of 011 liability. Note: Per Carmel zoning ordinance 26.1.1 : The residential district limits height to twenty-five feet (25'), howe....er 0 dwelling may be increased in height to thirty-five feet (35') provided the side and rear yards are increased an additional one foot (1') for each one foot (1') the structure exceeds the first twenty-five feet (25') in height. This Plot Plan Prepared For: R.H. of Indiana Lot # 103 , containing 6,012 S.F.:!:, in Stanford Pork Section # 1 INSlR. # 200500009385 P.C. # 3, Slide # 577 CERTIFlCA TE of CORRECTION INSlR. # 200500044195 Oay Twp, HomDton County Sec 29. T1aN. R3E 3469 Windy Knoll Lane Carmel, IN 46074 Prepared Dote: OS/25/06: By. AMA Proposed Buyer(s): INVENTORY (70'RjV() Plot Plan legend []QQ]] Proposed Grodes 000.0 Existing Grades _ 000.0-- Contour Grode * Approx. Lateral location - . - Sanitary Sewer lines -IT- Starm Sewer lines - IN - Water Service Lines - - - - - - - Sub-Surface Drain lines Q Manhole (Sonitory or Storm) . Beehive Inlet (Storm) IIIll Curb Inlet (Storm) D End Section (Storm) ./A. Fire Hydront _ 0 0 0 _ 0 0 0 - Flow Line of swale Building line (Bl / BSl) - - - - - - - Easement Line Detail of Ground/ Storm Water flow pattern for indi'liduollots. Lot # 103 Vb06.0055059 ~ D =R3l= ~ Assumed North Scale: 1. = 30' Community Restrictions: Side Yard =3' min. Rear Yard = N/A Aggregate = 6 (B. H.) R.H, of Indiana Finished Floor Elevation Information Pod Grode = 918.3 per pion Pod Grode + 0.7' = Goroge FFE (919.0) Garage FFE + 1.5' = Residential FFE (920.5) Residential FFE - 9.0' = Basement FFE (911.5 ) Note: The garage finished floor elevation is 1.3' above the curb at the drive, per plan. Ground Cover Calculations Drive = 610 SFf Public Walk = 129 SFf Private Walk = 91 SF f Hydroseeding =n/a SFf Sod = 409 SYI, from entire yard I ~r~B I <::( 1 -.J I-.J I --1~+~ w 10.""-1 " I Zei f~ I ~ de; / >-1 n. Ie ~ I:;::: 8 1/,;:s: } I I 1 1 1 I 1 z .~ o 4:) S OPt ~ .o\'~ SLOP€' TYPICAL SWALE SEcnON Sidewalk to be placed 7' from property line, 5' from bock of curb, per plan. Note; The contractor IS to maintain a minimum distance of ten feet (10') between the sanitry sewer and water line laterals. Note; Sanitary Sewer Top of Costing Information Upstreom Manhole, TC= 917.50 Downstream Manhole, Te= 918.20 per pion. Note: Sump pump(s) to be placed by builder os needed. i=:~ 5;'" ~~ [Q] -M- -w- -- - - Note: Builder to ensure positive drainage away from structure(s). Note: The basement elevotion, depicted hereon, has been determined and based upon the pad grades and/or contours taken from the construction plans for this subdivision. Unless stated, no information about fluctuating water tables, soil conditions, or sOH twes has been provided or stated on said plans. It is recommended that the basement finished floor ele\lOtions be at feast two feet (2') above the normal pool elevation of ony adjoining bodies of water, unless a study of facts reveals otherwise. If during the excavation process any ground water is witnessed, The Schneider Corporation should be notified immediately. The basement elevation should be raised two feet (2') above the ground water, and additional construction techniques should be incorporated to alleviate future problems. 58.37' "" 12142' ~ ;p !EO 60.38' "'''' ~'U ~ ~ Gi~ 1 2!~ ~ I~ M""<~ '-' "',-B- , I"" d "'~oo ~) bf#~ g .!:::: Cluo--- .;:::.. ~282'~ 32.4'__ V.; ~ -...J en. 44.38' 122.43' I / FLOOD HAZARD STATEMENT CERn FICA nON ,\\1\\\\\\\111111/111/1111//1. ;Jo.", c. L /1 Y.,.~ #' ~:)......:.....v;,pt'l~ ff ~",,~G\SNT €~~""'~,..<)~ g~...((- 0 o"',...o~ , ( 50303 ) , ~ ' . ~ % ..... STATE OF ./ ~ ~ /", / "" ,"<\ ~ ~ ~ ?"",>,/,y DI A t-\.~:...' ~~~ ~ Ff/I) .S....U..O\I\.-.l\ #' 1?0/11. {\ 't ~\~~ ////1111/1111111111\\1\1\\\ ~l~ Flood Haz.ard Statement: The accuracy oj any flood hazard data shown on this report is subject to map scale uncertainly and to any other uncertainty in location or elevation on the referenced flood insurance rate map. ALL of the within described land DOES NOT LIE within that special flood hazard zone A as said land plots by scale on flood insurance rale map # 18057 0205F for City of Carmel, Indiana (maps dated February 19, 2003) ~GNA lURE : DAIT: ~GNAlURE REPRESENTS CONFIRMATION OF RECEIPT Of PLOT PLAN BY CUSTOMER.