HomeMy WebLinkAbout06060037 Site Plan
LAKESIDE. PARK
INST./l.200500048185
LOT #103 - SECTION 3
CITY OF CARMEL, INDIANA
2734 HEATHERMOOR PARK DRIVE NORTH
HOUSE TYPE:
OPTIONS:
:.
PLOT
PLAN
PREPARED
FOR
DREES HOMES
SA VOY "c" - FULL BASEMENT
12'xlO' CONCRETE REAR PATIO
- 3-CAR SIDE-LOAD GARAGE
LOT SIZE:
CONC. DRIVEWAY:
PUBLIC WALK:
PRIVATE WALK:
SEEDING:
SOD:
12,662 SO. FT.
1,215:1: SO. FT.
358:1: SQ. FT.
189:1: SO.FT.
5.158:1: SO.FT.
467:1: SO. YD.
~,""~,;,,~
,,$'-:-"~-{ _ A. Tf:I:/'III~
;:; ,<<, .......... <-\;- ~
;::." .. STE .. --v ~
~ ...'!(r~\ J?(::... ~
: l q:. No. <:? \ ~
g * lLS20300026i * ~
S \ STATEOF l ~
::;. .::
~ <' ..../I\1Dlf\~~ .... ^- ~
~ -<lA, ........... _ll0~-~
~ 'VI' "","\;:;
~~III V SUR\jv ",<$I'
/111/'1/"11111111"'\
79.96'
,.,
lOp~
GRADE FLOWLINE../'
AS PER PLANS
TYPICAL SWy;LE SECTION
I
U
C
u
I \ I!
I[]/I
II ,I
II \ I
- - - I I
f ;" I I
N
<0
w ~I
LOT #103 I~ I
I 12,662 S.F. "'
.. ~I
I~ I
I f.D 500 U> <n
II) UNE I
~ 18.27' 1915.01
I 'i' 500 0
LINE I 0
ci I
I PROPOSED ...
10.00' b
-u RESIDENCE '" I
F.r. = 916.3' " I
~
22.12' 8SM'T. = 906.3' ~
I 914.5
~ I 1914.01 m
TI-lREE I N
:; CAR U>
PROP. ~
I DRIVE GARAGE ~
0
I I
~~J ~ z
25.00' <<10
~ ,,-
1915.01 22.37' ~ ::z;!
25' B.L. e <<m
w
3 SW-- 10 II
20' D.U.&S.S.E. u <no
12.00' u ~~
.0 =>~
SANITARY SEWER N
SUBSURFACE
DRAIN
913.5
4'SW
911.6
FRONT
DETAIL OF TYPICAL STORM
WATER FLOW PATTERN FOR
INDIVIDUAL LOTS
NOTE: 8UILDER TO ENSURE POSITIVE
DRAINAGE AWAY FROM STRUCTURE(S)
~lo
~:ri
wm
~
0"
:<:
z<J
:it-'
"
<<
w
10
"'
ii'
o
o
HEATHERMOOR PARK DRIVE NORTH
- - (50' R/W)
(30' 8-8)
/
/
/
f
~QJ - PROPOSED GRADE
000.0 - EXISTING GRADE
J:iQIh
_ DRIVE ENTRY TO CONFORM VY'lTH CITY OF CARMEL STD.
_ THE LOCATIONS, DIMENSIONS, AND INIDTH ALONG THE PROPOSED PUBLIC SIDEWALK WERE SCALED
OR TAKEN FROM ENGINEERING CONSTRUCTION PLANS PREPARED BY OTHERS OR AS PROVIDED.
- VERIFY SANITARY LATERAL LOCATION PRIOR TO CONSTRUCTION
- IT SHALL BE THE RESPONSIBILITY OF THE BUILDER/CONTRACTOR TO VERIFY THE BUILDING
DIMENSIONS, BUILDING LOCATIONS, THE LOCATION OF OTHER PERTINENT FEATURES AND
ElEVA110NS PRIOR TO THE START OF CONSTRUCTION. THE INTENDED USE OF THIS PLOT PLAN IS
FOR SECURING BUILDING PERMITS ONLY AND SHALL NOT 8E USED FOR ANY OTHER PURPOSE.
True N+rfh
5urvcyinq, LLC
.POINTlNG YOU IN THE RIGHT DIRECTION-
LAND SURVEYING &
LAND DEVELOPMENT CONSULTING
8055 WlNDHAM LAKE DRIVE
INDIANAPOLIS, INDIANA 46214
PHONE: (317)-290-1290
FAX: (.317)-290-129.3
DRWN: TAT
JOBH: 06-180
DATE, 05/31 /06
REV.:
SCALE: 1" - 3D'
ZONED:
ZONING: SPECIAL SIDE
REAR
F.F.E. HSE: 916.3'
F.F.E. GAR: 915.4'
F.F.E. BSM'T: 906.3'