HomeMy WebLinkAboutM201.0REFRIGERATOR OUTLET
MICROWAVE OUTLET
DISHWASHER POWER SUPPLY
HOOD VENT POWER SUPPLY
GARBAGE DISPOSAL POWER SUPPLY
COOKTOP POWER SUPPLY
CLOTHES DRYER OUTLET
CLOTHES WASHER OUTLET
110V OUTLET
220/240V OUTLET
GFCI OUTLET
OUTDOOR OUTLET
LOW VOLTAGE TRANSFORMER
SINGLE POLE SWITCH
DIMMER SWITCH
3-WAY SWITCH
4-WAY SWITCH
GD WALL SWITCH
GD COUNTERTOP AIR SWITCH
LOW VOLTAGE LIGHTING SWITCH
TIMER SWITCH
OCCUPANCY SWITCH
SURFACE MOUNT LIGHT FIXTURE
4" RECESSED CAN LIGHT
6" RECESSED CAN LIGHT
6" RECESSED CAN/FAN UNIT
EXHAUST FAN ONLY
EXHAUST FAN W/ LIGHT
WALL MOUNTED SCONCE / LIGHT
CEILING FAN
LOW VOLTAGE LIGHT
SMOKE DETECTOR
CARBON MONOXIDE DETECTOR
SMOKE/CARBON MONOXIDE
MOTION SENSOR
CEILING SPEAKER
GAS SHUT-OFF KEY
MAIN WATER SHUT-OFF
LAUNDRY BOX
FROST PROOF HOSE BIB
CLEAN OUT
TILE-IN DRAIN
FLOOR DRAIN
COLD AIR RETURN
FLOOR FLOOR SUPPLY REGISTER
CEILING CEILING SUPPLY REGISTER
WALL WALL SUPPLY REGISTER
EXTERIOR WALL EXHAUST VENT
T THERMOSTAT
DRYER BOX
ELECTRICAL KEY
PLUMBING KEY
HVAC KEY
N
6" 3000K
MODEL NO.
6RLD G3
07LM 30K
90CRI 120
FRPC WWH
M6
DECORA
WHITE
LEGRAND -
SCREWLESS
PADDLE SWITCH
- WHITECEILINGCEILINGFLOOR JOIST DIRECTION
R R
R R
R R
RR
DM
E4E4
E2E2
E6E6
H2H2
H1H1
ATTIC
C.H. 7'-6" AFF
LVT
EXISTING BATHROOM
USB OUTLETS
PROPOSED ELECTRICAL PLAN NOTES
NOTE QTY DESCRIPTION
1 ALL NEW FIXTURES AND DEVICES SHOWN TO BE PROVIDED
BY ELECTRICIAN U.N.O.
1
PROVIDE ROUGH IN AND FINISH FOR (8) OUTLETS IN NEW
LOCATIONS AS SHOWN. DEVICE STYLE AND COLOR
SHOWN. ALL OUTLETS TO BE STANDARD HEIGHT U.N.O. ALL
DEVICES TO BE STANDARD OUTLETS U.N.O.
1
VERIFY EXISTING PANEL SIZING WILL SUPPORT PROPOSED
ELECTRICAL. HOMEOWNERS UNDERSTAND IF THE PANEL
NEEDS TO BE UPDATED, THERE WILL BE AN ADDITIONAL
COST.
1
PROVIDE ROUGH IN AND FINISH FOR (8) (4") LED RECESSED
CANS IN LOCATIONS AS SHOWN. CANS TO BE LOCATED ON
FLAT PORTION OF CEILING. CURRENT ALLOWANCE DOES
NOT INCLUDE ANGLED CANS.
1
VERIFY EXISTING SMOKE AND CO DETECTORS MEET
CURRENT CODE REQUIREMENTS. HOMEOWNERS
UNDERSTAND THAT IF EXISTING FIXTURES NEED TO BE
BROUGHT UP TO CODE, THERE WILL BE AN ADDITIONAL
COST. THIS WILL BE DETERMINED ON A FIELD WALK.
1
REPLACE (1) EXISTING SWITCH WITH NEW DEVICE TO
MATCH NEW DEVICE STYLE. ALL NEW DEVICES TO BE
STANDARD SWITCHES UNLESS NOTED OTHERWISE.
E1E1
E2E2
E3E3
E4E4
E5E5
E6E6
E1E1
E2E2
E3E3
E4E4
E5E5
E6E6
PROPOSED HVAC PLAN NOTES
NOTE QTY DESCRIPTION
1
ADD NEW RETURN VENTS AS REQUIRED FOR PROPOSED
PLAN. VERIFY EXISTING HVAC SYSTEM WILL SUPPORT
ADDITIONAL VOLUME OF PROPOSED SPACE. VERIFY FINAL
LOCATIONS ON SITE DURING ROUGH IN. HVAC
CONTRACTOR TO PROVIDE WHITE RETURN VENT COVER.
1
ADD NEW SUPPLY VENTS AS REQUIRED FOR PROPOSED
PLAN. VERIFY EXISTING HVAC SYSTEM WILL SUPPORT
ADDITIONAL VOLUME OF PROPOSED SPACE. VERIFY FINAL
LOCATIONS ON SITE DURING ROUGH IN. CUSTOM LIVING
TO PROVIDE DECORATIVE VENT COVERS.
H1H1
H2H2
H1H1
H2H2
USB OUTLET
WHITE
KANE RESIDENCEInterior/Exterior Remodel14344 Jeremy DrCarmel, IN, 46032Date:Revision:
A10
SHEET OF 14
SIGNATURE / SEAL
Client Initials:
Date:
The plans, including all text, drawings, concepts, and ideas
forming a part of the plans and the selection and arrangement
thereof are Copyright 2018 of Custom Living, Inc., Indianapolis,
IN. ALL RIGHTS RESERVED. The plans shall remain the
property of Custom Living Inc. Any use of the plans or their
content without the prior written permission of Custom Living Inc.
is strictly prohibited.CUSTOM LIVING5335 Winthrop AveIndianapolis IN 4622011/10/22
DATE:
[PRINTS TO SCALE IF PRINTED ON 24" X 36" ]DESIGNER: BAYLEE FLORENCEE: baylee@customlivingusa.comC: 219.713.4954ATTIC - PROPOSED M.E.P. PLAN
SCALE: 3/8" = 1'
NEW OUTLET DEVICE STYLE
NEW SWITCH DEVICE STYLE
RECESSED CAN LIGHTS
DECORATIVE LIGHT FIXTURES
UNDER CABINET LIGHTING
N/A
N/A
GENERAL M.E.P NOTES
HVAC Contractor is responsible for engineering
calculation necessary for correct sizing of new equipment
and ductwork being supplied, fabricated and installed for
the project.
HVAC ductwork installed in unconditioned areas to be
insulated and sealed per Building Code Standards.
HVAC contractor to start, test, and balance any new
equipment and ductwork to assure proper operation of
new systems.
Final plumbing materials selected may have an affect on
the final Plumbing Material and Installation Budgets.
Owners understand that if additional plumbing, electrical
or ductwork is found in walls being deleted that is not
included on the plans there will be a Change Order
during construction to relocate as necessary.
Owners understand that during mechanical rough-ins
there will be times when the water service will be shut off
to areas in the home.
Plumbing and Lighting fixtures supplied by Owner will not
be warranted by Custom Living
Plumbing and Lighting fixtures supplied by Owner must
be selected and on-site prior to start of mechanical rough-
ins.
11/18/22