HomeMy WebLinkAboutS100.0N EXISTING 2X4 FRAMING DEMOLITION & FRAMING KEY NO DEMO IN THIS ROOM EXISTING 2X6 FRAMING WALL SECTION TO BE REMOVED NEW 2x4 FRAMING NEW 2X6 FRAMING BULK HEAD / LOWERED CEILING 30X22 ATTIC ACCESS WALL FLOOR JOIST DIRECTION R R R R 6'-0 1/8"7'-0 3/8"4'-7 3/4"5'-8 1/4"13'-9"13'-3 3/8"MASTER BATH C.H. 9'-0" AFF TILE D4D4 D5D5 D6D6 D7D7 D3D3 D8D8 D9D9 E2E2 E3E3 P2P2 P3P3 H2H2 D7D7 E4E4 E5E5 E5E5 NOT IN SCOPE P4P4 DEMO & PREP PLAN NOTES NOTE QTY DESCRIPTION 1 INSTALL FLOOR PROTECTION FROM DOOR TO BE USED AS CONSTRUCTION ENTRANCE TO LOCATIONS OF REMODEL (FRONT DOOR). INSTALL PLASTIC SHEATHING AND ZIPPER WALL AT THE FOLLOWING LOCATIONS: ENTRANCE TO STAIRWELL, ENTRANCE TO MASTER BEDROOM 1 INSTALL RAILING AND STAIR PROTECTION 1 REMOVE ALL SHOE MOLDING, BASEBOARD AND CROWN MOLDING IN REMODEL LOCATION (TRASH) 1 REMOVE ALL EXISTING CABINETS & COUNTERTOPS IN MASTER BATH (TRASH). 1 DEMO SHOWER SURROUND DOWN TO STUDS (TRASH) 1 DEMO TILE FLOORING & TUB SURROUND DOWN TO SUBFLOOR. 2 DEMO INTERIOR DOOR SLAB, CASING, JAMB & ALL HARDWARE (TRASH). NEW DOOR SLABS TO BE HUNG IN PROPOSED. 1 REMOVE DRYWALL NECESSARY FOR MECHANICAL ROUGH INS 1 REMOVE SUBFLOOR NECESSARY FOR MECHANICAL ROUGH INS. D1D1 D2D2 D3D3 D4D4 D5D5 D6D6 D7D7 D8D8 D9D9 D1D1 D2D2 D3D3 D4D4 D5D5 D6D6 D7D7 D8D8 D9D9 PLUMBING DEMO/DISCONNECT PLAN NOTES NOTE QTY DESCRIPTION 1 SEPARATE PLUMBING PERMIT NOT REQUIRED. 1 DISCONNECT AND REMOVE EXISTING TOILET (TRASH) & CAP LINES PRIOR TO DEMOLITION. NEW TOILET TO BE INSTALLED IN NEW LOCATION AS SHOWN ON PROPOSED MEP PLANS. 1 DISCONNECT VANITY SINKS PRIOR TO DEMOLITION & CAP LINES (TRASH FIXTURES). NEW SINK AND FAUCET TO BE INSTALLED IN NEW LOCATIONS AS SHOWN ON PROPOSED MEP PLANS. 1 DISCONNECT AND REMOVE EXISTING BUILT-IN TUB (TRASH) & CAP LINES PRIOR TO DEMOLITION. NEW FREESTANDING TUB TO BE INSTALLED IN NEW LOCATION AS SHOWN ON PROPOSED MEP PLANS. P1P1 P2P2 P3P3 P4P4 P1P1 P2P2 P3P3 P4P4 ELECTRICAL DEMO/DISCONNECT NOTES NOTE QTY DESCRIPTION 1 SEPARATE ELECTRICAL PERMIT NOT REQUIRED. 1 DISCONNECT EXISTING ELECTRICAL IN WALLS TO BE DELETED PRIOR TO DEMOLITION 1 REMOVE EXISTING DECORATIVE FIXTURE PRIOR TO DEMOLITION (TRASH). NEW FIXTURE TO BE INSTALLED IN NEW LOCATION AS SHOWN ON PROPOSED MEP PLAN. 1 REMOVE EXISTING FAN UNITS PRIOR TO DEMOLITION (TRASH). NEW FIXTURE TO BE INSTALLED IN NEW LOCATION AS SHOWN ON PROPOSED MEP PLAN. 2 REMOVE EXISTING RECESSED CANS/TRIMS PRIOR TO DEMOLITION (TRASH). NEW FIXTURE TO BE INSTALLED IN NEW LOCATION AS SHOWN ON PROPOSED MEP PLAN. E1E1 E2E2 E3E3 E4E4 E5E5 E1E1 E2E2 E3E3 E4E4 E5E5 GENERAL NOTES NOTE QTY DESCRIPTION 1 DUMPSTER AND PORTALET LOCATIONS TO BE DETERMINED ON SITE W/ HOMEOWNERS 1 HOMEOWNERS TO MOVE ALL NECESSARY FURNITURE FROM AREAS OF REMODEL PRIOR TO START OF WORK 1 HOMEOWNERS TO REMOVE ALL WINDOW COVERINGS PRIOR TO START OF WORK 1 TBD - HOMEOWNERS TO CLEAR OUT SPACE IN GARAGE FOR STORAGE OF BUILDING MATERIALS PRIOR TO START OF WORK. GN1GN1 GN2GN2 GN3GN3 GN4GN4 GN1GN1 GN2GN2 GN3GN3 GN4GN4 HVAC DEMO/DISCONNECT NOTES NOTE QTY DESCRIPTION 1 SEPARATE HVAC PERMIT NOT REQUIRED. 1 VERIFY EXISTING BATH FIXTURES ARE VENTED TO EXTERIOR. H1H1 H2H2 H1H1 H2H2 KANE RESIDENCEInterior/Exterior Remodel14344 Jeremy DrCarmel, IN, 46032Date:Revision: A3 SHEET OF 14 SIGNATURE / SEAL Client Initials: Date: The plans, including all text, drawings, concepts, and ideas forming a part of the plans and the selection and arrangement thereof are Copyright 2018 of Custom Living, Inc., Indianapolis, IN. ALL RIGHTS RESERVED. The plans shall remain the property of Custom Living Inc. Any use of the plans or their content without the prior written permission of Custom Living Inc. is strictly prohibited.CUSTOM LIVING5335 Winthrop AveIndianapolis IN 4622011/10/22 DATE: [PRINTS TO SCALE IF PRINTED ON 24" X 36" ] GENERAL SITE PREP & DEMO NOTES Install plastic to seal off areas being remodeled from rest of home as necessary. Install floor covering for construction path from door designated as the construction entrance to locations of remodeling as necessary. Install additional floor covering or wall protection as needed over areas close to the areas of construction activity. Install dust control measures on HVAC cold air returns located within the locations of remodeling. Custom Living can provide a HEPA Air Scrubber to aid in airborne dust control from the start of demolition up to priming of new drywall depending on site conditions. Homeowner understands that this will help to reduce airborne dust; however, it will not mitigate it in its entirety. Demolition Contractor(s) are responsible for all labor, for the scope of work specified in the drawings provided by Custom Living. Homeowner understands that Custom Living has only provided a labor and material allowance for the scope of demolition denoted on the drawings. Any additional scope added or uncovered during demolition result in filing a Change Order during construction. Homeowners understand that demolition work will generate dust and noise throughout the house. Custom Living will provide site protection measures to reduce where possible, but Homeowners should not expect 100% containment. MASTER BATH - EXISTING / DEMO PLAN SCALE: 1/2" = 1'DESIGNER: BAYLEE FLORENCEE: baylee@customlivingusa.comC: 219.713.495411/18/22