HomeMy WebLinkAboutS100.0N
EXISTING 2X4 FRAMING
DEMOLITION & FRAMING KEY
NO DEMO IN THIS ROOM
EXISTING 2X6 FRAMING
WALL SECTION TO BE REMOVED
NEW 2x4 FRAMING
NEW 2X6 FRAMING
BULK HEAD / LOWERED CEILING
30X22
ATTIC
ACCESS
WALL
FLOOR JOIST DIRECTION
R
R
R
R
6'-0 1/8"7'-0 3/8"4'-7 3/4"5'-8 1/4"13'-9"13'-3 3/8"MASTER BATH
C.H. 9'-0" AFF
TILE
D4D4
D5D5
D6D6
D7D7
D3D3
D8D8
D9D9
E2E2
E3E3
P2P2
P3P3
H2H2
D7D7
E4E4
E5E5
E5E5
NOT IN SCOPE
P4P4
DEMO & PREP PLAN NOTES
NOTE QTY DESCRIPTION
1
INSTALL FLOOR PROTECTION FROM DOOR TO BE USED AS
CONSTRUCTION ENTRANCE TO LOCATIONS OF REMODEL
(FRONT DOOR). INSTALL PLASTIC SHEATHING AND ZIPPER
WALL AT THE FOLLOWING LOCATIONS: ENTRANCE TO
STAIRWELL, ENTRANCE TO MASTER BEDROOM
1 INSTALL RAILING AND STAIR PROTECTION
1 REMOVE ALL SHOE MOLDING, BASEBOARD AND CROWN
MOLDING IN REMODEL LOCATION (TRASH)
1 REMOVE ALL EXISTING CABINETS & COUNTERTOPS IN
MASTER BATH (TRASH).
1 DEMO SHOWER SURROUND DOWN TO STUDS (TRASH)
1 DEMO TILE FLOORING & TUB SURROUND DOWN TO
SUBFLOOR.
2
DEMO INTERIOR DOOR SLAB, CASING, JAMB & ALL
HARDWARE (TRASH). NEW DOOR SLABS TO BE HUNG IN
PROPOSED.
1 REMOVE DRYWALL NECESSARY FOR MECHANICAL ROUGH
INS
1 REMOVE SUBFLOOR NECESSARY FOR MECHANICAL
ROUGH INS.
D1D1
D2D2
D3D3
D4D4
D5D5
D6D6
D7D7
D8D8
D9D9
D1D1
D2D2
D3D3
D4D4
D5D5
D6D6
D7D7
D8D8
D9D9
PLUMBING DEMO/DISCONNECT PLAN NOTES
NOTE QTY DESCRIPTION
1 SEPARATE PLUMBING PERMIT NOT REQUIRED.
1
DISCONNECT AND REMOVE EXISTING TOILET (TRASH) &
CAP LINES PRIOR TO DEMOLITION. NEW TOILET TO BE
INSTALLED IN NEW LOCATION AS SHOWN ON PROPOSED
MEP PLANS.
1
DISCONNECT VANITY SINKS PRIOR TO DEMOLITION & CAP
LINES (TRASH FIXTURES). NEW SINK AND FAUCET TO BE
INSTALLED IN NEW LOCATIONS AS SHOWN ON PROPOSED
MEP PLANS.
1
DISCONNECT AND REMOVE EXISTING BUILT-IN TUB (TRASH)
& CAP LINES PRIOR TO DEMOLITION. NEW FREESTANDING
TUB TO BE INSTALLED IN NEW LOCATION AS SHOWN ON
PROPOSED MEP PLANS.
P1P1
P2P2
P3P3
P4P4
P1P1
P2P2
P3P3
P4P4
ELECTRICAL DEMO/DISCONNECT NOTES
NOTE QTY DESCRIPTION
1 SEPARATE ELECTRICAL PERMIT NOT REQUIRED.
1 DISCONNECT EXISTING ELECTRICAL IN WALLS TO BE
DELETED PRIOR TO DEMOLITION
1
REMOVE EXISTING DECORATIVE FIXTURE PRIOR TO
DEMOLITION (TRASH). NEW FIXTURE TO BE INSTALLED IN
NEW LOCATION AS SHOWN ON PROPOSED MEP PLAN.
1
REMOVE EXISTING FAN UNITS PRIOR TO DEMOLITION
(TRASH). NEW FIXTURE TO BE INSTALLED IN NEW
LOCATION AS SHOWN ON PROPOSED MEP PLAN.
2
REMOVE EXISTING RECESSED CANS/TRIMS PRIOR TO
DEMOLITION (TRASH). NEW FIXTURE TO BE INSTALLED IN
NEW LOCATION AS SHOWN ON PROPOSED MEP PLAN.
E1E1
E2E2
E3E3
E4E4
E5E5
E1E1
E2E2
E3E3
E4E4
E5E5
GENERAL NOTES
NOTE QTY DESCRIPTION
1 DUMPSTER AND PORTALET LOCATIONS TO BE
DETERMINED ON SITE W/ HOMEOWNERS
1 HOMEOWNERS TO MOVE ALL NECESSARY FURNITURE
FROM AREAS OF REMODEL PRIOR TO START OF WORK
1 HOMEOWNERS TO REMOVE ALL WINDOW COVERINGS
PRIOR TO START OF WORK
1
TBD - HOMEOWNERS TO CLEAR OUT SPACE IN GARAGE
FOR STORAGE OF BUILDING MATERIALS PRIOR TO START
OF WORK.
GN1GN1
GN2GN2
GN3GN3
GN4GN4
GN1GN1
GN2GN2
GN3GN3
GN4GN4
HVAC DEMO/DISCONNECT NOTES
NOTE QTY DESCRIPTION
1 SEPARATE HVAC PERMIT NOT REQUIRED.
1 VERIFY EXISTING BATH FIXTURES ARE VENTED TO
EXTERIOR.
H1H1
H2H2
H1H1
H2H2 KANE RESIDENCEInterior/Exterior Remodel14344 Jeremy DrCarmel, IN, 46032Date:Revision:
A3
SHEET OF 14
SIGNATURE / SEAL
Client Initials:
Date:
The plans, including all text, drawings, concepts, and ideas
forming a part of the plans and the selection and arrangement
thereof are Copyright 2018 of Custom Living, Inc., Indianapolis,
IN. ALL RIGHTS RESERVED. The plans shall remain the
property of Custom Living Inc. Any use of the plans or their
content without the prior written permission of Custom Living Inc.
is strictly prohibited.CUSTOM LIVING5335 Winthrop AveIndianapolis IN 4622011/10/22
DATE:
[PRINTS TO SCALE IF PRINTED ON 24" X 36" ]
GENERAL SITE PREP & DEMO NOTES
Install plastic to seal off areas being remodeled
from rest of home as necessary.
Install floor covering for construction path from
door designated as the construction entrance to
locations of remodeling as necessary.
Install additional floor covering or wall protection
as needed over areas close to the areas of
construction activity.
Install dust control measures on HVAC cold air
returns located within the locations of
remodeling.
Custom Living can provide a HEPA Air Scrubber
to aid in airborne dust control from the start of
demolition up to priming of new drywall
depending on site conditions. Homeowner
understands that this will help to reduce airborne
dust; however, it will not mitigate it in its entirety.
Demolition Contractor(s) are responsible for all
labor, for the scope of work specified in the
drawings provided by Custom Living.
Homeowner understands that Custom Living
has only provided a labor and material
allowance for the scope of demolition denoted
on the drawings. Any additional scope added or
uncovered during demolition result in filing a
Change Order during construction.
Homeowners understand that demolition work
will generate dust and noise throughout the
house. Custom Living will provide site protection
measures to reduce where possible, but
Homeowners should not expect 100%
containment.
MASTER BATH - EXISTING / DEMO PLAN
SCALE: 1/2" = 1'DESIGNER: BAYLEE FLORENCEE: baylee@customlivingusa.comC: 219.713.495411/18/22