HomeMy WebLinkAboutS101.0N 1'-4" 8'HEADER (WINDOWS & DOORS): DOUBLE 2X8 DOUBLE TOP PLATE KING STUD CRIPPLE STUD BOTTOM PLATE O.C. 3/4" SUBFLOOR 2x8 CEILING JOISTS 16" OC 11 7/8" I JOIST FLOOR JOISTS SPACED @ 16" O.C. EXISTING 2X4 FRAMING DEMOLITION & FRAMING KEY NO DEMO IN THIS ROOM EXISTING 2X6 FRAMING WALL SECTION TO BE REMOVED NEW 2x4 FRAMING NEW 2X6 FRAMING BULK HEAD / LOWERED CEILING 3DB18SB36SB363DB183DB18SB36SB363DB184020FLOOR JOIST DIRECTION 30X22 ATTIC ACCESS WALLD01 D01 GFCI GFCI DM DMT T DM R R RR R R AA A5'-5 7/8"5'-7 3/4"6'-4 1/8"8'-2 5/8"12'-2 7/8"CL 2'-11 3/4"5'-8 1/4"1'-4"D2D2 D3D3 F3F3 F4F4 NOT IN SCOPE F1F1 F5F5 F6F6 F6F6 F7F7 FRAMING PLAN NOTES NOTE QTY DESCRIPTION 1 FRAME NEW INTERIOR WALLS AS SHOWN 1 INSTALL NEW SUBFLOOR AS NECESSARY FROM DEMO AND MECHANICAL ROUGH INS. FINAL SCOPE TO BE DETERMINED FOLLOWING MECHANICAL ROUGH INS. 1 FRAME SHOWER NICHE PER TILE DETAIL DRAWINGS. INSTALL BLOCKING FOR SHOWER GLASS INSTALLATION. 1 PROVIDE BLOCKING FOR CABINET INSTALLATION & BATHROOM ACCESSORIES 1 PROVIDE BLOCKING FOR SHOWER GLASS INSTALLATION 2 NEW PREHUNG DOORS TO GO IN EXISTING FRAMED ROUGH OPENINGS. 1 INSPECT HUMP IN FLOOR FOLLOWING TILE/SUBFLOOR REMOVAL. F1F1 F2F2 F3F3 F4F4 F5F5 F6F6 F7F7 F1F1 F2F2 F3F3 F4F4 F5F5 F6F6 F7F7 INSULATION PLAN NOTES NOTE QTY DESCRIPTION 1 FOAM AND FIRECAULK ALL MECHANICAL OPENINGS PER MUNICIPAL CODE REQUIREMENTSI1I1I1I1 DRYWALL PLAN NOTES NOTE QTY DESCRIPTION 1 EXISTING DRYWALL FINISH NOTES; (WALLS) SMOOTH- LEVEL 4, (CEILINGS) TEXTURED 1 INSTALL NEW DRYWALL ON ALL NEWLY FRAMED WALLS. PATCH ALL AREAS NECESSARY FROM DEMO AND MECHANICAL ROUGH INS. MATCH EXISTING DRYWALL FINISH. INCLUDE DRYWALL PATCH FOLLOWING COUNTERTOP INSTALLATION. FINAL SCOPE TO BE DETERMINED FOLLOWING MECHANICAL ROUGH INS. 1 INSTALL NEW DRYWALL ON ALL CEILINGS NECESSARY FROM DEMO AND MECHANICAL ROUGH INS, INCLUDING DRYWALL CEILING IN SHOWER. MATCH EXISTING CEILING FINISH IN HOME (TEXTURED). FINAL SCOPE TO BE DETERMINED FOLLOWING MECHANICAL ROUGH INS. D1D1 D2D2 D3D3 D1D1 D2D2 D3D3 INTERIOR DOOR SCHEDULE - 1ST FLOOR NUMBER FLOOR DESCRIPTION QTY R/O WIDTH HEIGHT D01 1 UNSPECIFIED / HINGED 2 38"X82 1/4"36 " 80 "KANE RESIDENCEInterior/Exterior Remodel14344 Jeremy DrCarmel, IN, 46032Date:Revision: A5 SHEET OF 14 SIGNATURE / SEAL Client Initials: Date: The plans, including all text, drawings, concepts, and ideas forming a part of the plans and the selection and arrangement thereof are Copyright 2018 of Custom Living, Inc., Indianapolis, IN. ALL RIGHTS RESERVED. The plans shall remain the property of Custom Living Inc. Any use of the plans or their content without the prior written permission of Custom Living Inc. is strictly prohibited.CUSTOM LIVING5335 Winthrop AveIndianapolis IN 46220 11/10/22 DATE: [PRINTS TO SCALE IF PRINTED ON 24" X 36" ] GENERAL PROPOSED PLAN NOTES Framing contractors are responsible for all labor, for the scope of work specified on the drawings provided by Custom Living. Owner understands that Custom Living has only provided a labor and material allowance for the scope of Rough Carpentry work specified on the drawings. Any additional work added or uncovered during this scope will be filed as a Change Order during construction Owner understands that the drywall allowance is based on an estimated board count and square footage take-off. A final walk through with a drywall contractor after framing and mechanical rough-ins will be necessary to finalize drywall installation and finish budgets. Final drywall touch-ups will follow countertop installation. MASTER BATH - PROPOSED FLOOR PLAN SCALE: 1/2" = 1' TYPICAL FRAMING DETAIL SCALE: 3/8" = 1' 0" DESIGNER: BAYLEE FLORENCEE: baylee@customlivingusa.comC: 219.713.4954 11/18/22