HomeMy WebLinkAboutFloor Plan 10-17EXISTINGFIREPLACETO REMAINW.C.
L.
SERVICE KITCHEN
& PANTRY
FREEZER
2'-6" 2'-6" 2'-6"
SINK SHELVESFLOOR - CEILINGELEC.
PANEL
EXISTING WINDOW TO BE
REMOVED. FRAME IN AS
REQUIRED
(VERIFY w/ CONTRACTOR)
EXISTING WINDOW TO BE
REMOVED. FRAME IN AS
REQUIRED
(VERIFY w/ CONTRACTOR)
EXISTING WINDOW TO BE
REMOVED. FRAME IN AS
REQUIRED
(VERIFY w/ CONTRACTOR)
EXISTING WINDOW TO BE
REMOVED. FRAME IN AS
REQUIRED
(VERIFY w/ CONTRACTOR)
WORK STORAGE
NOOK
W. D.HANG
ROD
BOOR BENCH
KEY DROP REPLACE EXISTINGFRENCH DOOR UNITNOTE:
EXISTING DECK STRUCTURE AND
CONCRETE TO BE REMOVED
(VERIFY w/ CONTRACTOR)
SINK
EXISTING WINDOW TOBE REMOVED. FRAMEIN AS REQUIRED(VERIFY w/ CONTRACTOR)SPACE FOR
FREEZER DOOR
TO OPEN FULLY
DRINK LEDGE
4'-0"5'-0"
6'8"x12'0" SLIDING GLASS
DOOR UNIT
BEAM EQUALLY
SPACED
BEAM EQUALLY
SPACED
BEAM EQUALLY
SPACED
BEAM EQUALLY
SPACED
ADD NEW BRICK
(VERIFY w/ CONTRACTOR)
ADD NEW BRICK
(VERIFY w/ CONTRACTOR)
W.C.
L.
W.C.
MASTER BEDROOM
MASTER
BATHROOM
SHOWER
BATHROOM
WALK-IN CLOSET
WALK-IN
CLOSET
SHOWERSIT DOWNL.
SEATING ROOM
SHELF ABOVE SOFA
SMALL BUILT-IN
END TABLE
BOOKS/
DISPLAY
SMALL BUILT-IN
END TABLE
84" SOFA
BOOKS/
DISPLAY
MEDIA
LAUNDRY
TALL
CLEANING
CABINET
BEAM EQUALLY
SPACED
BEAM EQUALLY
SPACED
BEAM EQUALLY
SPACED
BEAM EQUALLY
SPACED
BEAMBEAMBEAMBEAMBEAMDINING AREA CLOSETCLOSETCLOSETCLOSETNEW
COVERED PORCH
2 CAR GARAGE
SERVICE ENTRY
NOTE: GABLE TRUSS THAT SITS
ON TOP OF CABINETS
(VERIFY w/ CONTRACTOR
AND GARY NANCE FOR DESIGN)
CENTER OF
RIDGE BEAM SLOPEDCEILINGSLOPEDCEILINGSLOPEDCEILINGSLOPEDCEILING- 8'0" CEILING HEIGHT
(TO MATCH EXISTING)
BEDROOM #2
3'0"
x
6
'
8
"2'6"x6'8"3'0"x6'8"
POCKET DOOR
3'6"x6'8"
CASED OPENING2'8"x6'8"POCKET DOOR2'6"x6'8"
2'4"x6'8"
POCKET DOOR2'8
"x6'8"1'6"x6'8" PAIRDOORS2 '8"x6'8 "3'0"x6'8"POCKETDOOR2'0
"x6
'8
"2'8"x6'8"2'8"x6
'8"
2'8"x6'8"
POCKET DOOR
2'8"x6'8"
CASED OPENING
2'8"x6'8"SLIDINGSTYLE DOORCLOSETCLOSETEXISTING DOOR TO BE
REMOVED. FRAME IN AS
REQUIRED
(VERIFY w/ CONTRACTOR)
KITCHEN
EXISTING WINDOW TO BE
REMOVED. FRAME IN AS
REQUIRED
(VERIFY w/ CONTRACTOR)BUILT - INCABINETSBUILT - INCABINETSBUILT - INCABINETSBUILT - INCABINETS22'-7" FACE OF NEW SHEATHING
23'-0"10'-178"9'-1134"7'-4"11'-214"4'-034"2'-1038"15'-412"FACE OF EXISTINGSTUD FRAMING TO NEWSTUD FRAMING5'-6"23'-1112"16'-912"FACE OF BRICK(VERIFY w/ CONTRACTOR)4'-734"5'-1014"FACE OF BRICK
(VERIFY w/
CONTRACTOR)3'-8"15'-8"FACE OF BRICK
(VERIFY w/
CONTRACTOR)7'-212"VERIFY AT SITE12'-112"FACE OF BRICK
(VERIFY w/
CONTRACTOR)
18'-312"
EXISTING STRUCTURE
BRICK TO BRICK
7'-10" 13'-0"9'-8"
FACE OF SHEATHING
(VERIFY w/
CONTRACTOR)46'-3"30'-6"
4" 14'-0" 512" 7'-512" 4"
4'-1" 312" 3'-4"312" 6'-212"
5'-7"312" 3'-1112"2'-8"2'-912"8'-7"912"512"13'-312"512"6'-2"312"3'-1112"1'-3"512"2'-212"4'-7"312"8'-1"4'-7"312"4'-1112"
2'-412"3'-5"312"4'-4"312"3'-5"4'-012"312"6'-7"512"5'-6" 8'-1"5'-812"7'-212"512"312"10'-8"312"7'-412"5'-812"312"5'-7"312"2'-6"4'-1"312"4'-7" 312"12'-8"3 12"2 STEPSDOWN TOGARAGE4'-1118" 8'-058" 8'-058" 8'-058" 4'-1118"FACE OF BRICK
(VERIFY w/ CONTRACTOR)
FACE OF BRICK
(VERIFY w/ CONTRACTOR)
ADD NEW BRICK
(VERIFY w/ CONTRACTOR)
1'-41316"8'-0"1'-3"1'-0"101316"
8'-1138" 8'-058" 8'-058"
1'-41316"
101316"
8'-1138"
6'0"x6'8"
DOOR UNIT
3'0"x6'8"
14" S.L.14" S.L.
6'0"x6'8"
DOOR UNIT
6'0"x6'8"
DOOR UNIT
NEW 16'0"x7'0" GARAGE DOOR2'-712"312"FACE OF EXISTING STUD
(VERIFY w/ CONTRACTOR)15'-012"REPLACE EXISTING
WINDOWS
(VERIFY WINDOW
SPECS. AT SITE)
REPLACE EXISTING
WINDOWS
(VERIFY WINDOW
SPECS. AT SITE)
REPLACE EXISTING
WINDOWS
(VERIFY WINDOW
SPECS. AT SITE)
1
1
22
2844284428442444364436443660-3
2844-3
13'-0"3'0"x6'8"CASED OPENING1'-0"
4
4
4 43660
36602-PLYx111
4
LVL HDR.
EXISTING BRICK
TO BE REMOVED
(VERIFY w/ CONTRACTOR)
ADD NEW BRICK
(VERIFY w/ CONTRACTOR)
FLAT
SOFFIT
NOTE: GABLE TRUSS THAT SITS
ON TOP OF CABINETS
(VERIFY w/ CONTRACTOR
AND GARY NANCE FOR DESIGN)BEAMBEAMBEAMBEAMBEAMGAS
SINKLAYOUT AS PER
KITCHEN DESIGNER
MECHANICALS
W/H SOFTENER
FURNACE(EXISTING LOCATION)48"RANGE2'0"x6'8"2'0"x6'8"2'8
"
x6'8
"
WATER
DISPENSER
- 8'0" CEILING HEIGHT
- 8'0" CEILING HEIGHT
- 8'0" CEILING HEIGHT
- 8'0" CEILING HEIGHT
- 8'0" CEILING HEIGHT
3. GENERAL NOTES
2x10 BLOCKING
FLUSH w/ INSIDE
FACE OF STUDS
8"
5. WINDOW/DOOR HEAD FRAMING DETAIL (TYP.)6"CONSTRUCTION LEGEND
1. AREA LEGEND
INTERIOR DIMENSIONS TO FACE OF STUD WALLS
EXTERIOR DIMENSIONS TO FACE OF SHEATHING
4. DIMENSION NOTES
LVL HEADER (VERIFY
SIZING w/ LUMBER
MANUFACTURER)
8'-0" CEILING HEIGHT UNLESS OTHERWISE NOTED. MATCH EXISTING CEILING
HEIGHTS. VERIFY AT SITE w/ CONTRACTOR
POCKET DOORS:
TRIPLE 2x12 HEADER w/1
2" PLYWOOD GUSSETS 2 PLY SOLID
BLOCKING BOTH SIDES (TYP.)
VERIFY WINDOWS w/ OWNER/CONTRACTOR. MARVIN WINDOWS SHOWN,
VERIFY WINDOW NUMBERS AND SIZING w/ WINDOW MANUFACTURER AFTER
THIS IS COMPLETE. PLEASE PROVIDE H.G. McCULLOUGH DESIGNERS w/ A
WINDOW LIST.
FLOOR JOIST MANUFACTURERS ARE TO SUPPLY H.G. McCULLOUGH
DESIGNERS w/ ALL NECESSARY FLOOR FRAMING PLANS, INCLUDING MAIN,
SECOND AND ROOF PLAN. H.G. McCULLOUGH DESIGNERS IS TO BE NOTIFIED
DURING THE FLOOR FRAMING DESIGN PROCESS IF IT DEVIATES FROM THE
ORIGINAL PLAN. wE WILL REVIEW THE CHANGES w/ ONE ANOTHER.
MAIN LEVEL FLOOR JOIST SYSTEM - 60 LBS. P.S.F. TOTAL FLOOR LOAD.
PROVIDE SOLID BLOCKING BETWEEN FLOORS UNDER ALL BEARING WALLS
AND COLUMNS ABOVE.
ALL WALLS ALIGNED w/ FLOOR JOIST DIRECTION TO HAVE FLOOR JOIST
BELOW.
CONTRACTOR IS RESPONSIBLE FOR COMPLIANCE WITH CODES, ORDINANCES,
AND REGULATIONS APPLICABLE TO THE PROJECT LOCATION.
CONTRACTOR SHALL NOT SCALE DRAWINGS. IF ADDITIONAL INFORMATION IS
REQUIRED TO CLARIFY THESE DOCUMENTS , THE CONTRACTOR SHALL
CONTACT THE DESIGNER IMMEDIATELY.
WHEN "APPROVED EQUAL" , "EQUAL TO", OR OTHER QUALIFYING TERMS ARE
USED, IT SHALL BE BASED UPON THE REVIEW OF THE CONTRACTOR/OWNER'S.
THE DESIGNER SHALL BE NOTIFIED OF MATERIALS BEING INSTALLED.
DRAWINGS ESTABLISH THE DESIGN INTENT OF WORK TO BE PERFORMED. ALL
WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE HIGHEST INDUSTRY
STANDARDS. ALL PRODUCTS SHALL BE INSTALLED BY THE CONTRACTOR IN
ACCORDANCE WITH THE MANUFACTURER'S
SPECIFICATIONS/RECOMENDATIONS. ANY DISCREPANCIES OR CONFLICTS
SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE DESIGNER AND
THE OWNER PRIOR TO FABRICATION OR INSTALLATION.
CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD VERIFYING EXISTING
CONDITIONS AND FOR VERIFYING THEM WITH THE DRAWINGS. ANY
DISCREPANCY IN THE DRAWINGS AND SPECIFICATIONS SHALL BE BROUGHT
TO THE NOTICE OF THE DESIGNER PRIOR TO ANY FABRICATION OR
CONSTRUCTION.
CONTRACTOR SHALL PROVIDE ALL NECESSARY REQUIRED PLANS TO ALL
SUB-CONTRACTORS.
BEARING WALLS
2. MATERIALS LEGEND - REMODEL CONSTRUCTION
NEW FRAME WALLS
BRICK VENEER
EXISTING WALLS
WALLS TO BE REMOVED
EXISTING MAIN:
MAIN LEVEL
2395 SQUARE FEET
EXISITNG CAR GARAGE: 540 SQUARE FEET
NEW MAIN: 350 SQUARE FEET
Date: 10-14-2022Plan number #220802Designed For:Perkins & RoseH. G. McCULLOUGH DESIGNERS, INCCONSTRUCTION DRAWINGS BY:- 2146 Glenview Drive, Evansville, IN 47720 - Email: designers@hgmccullough.com- Telephone: 812 . 428 . 0174- www.hgmccullough.comGARY NANCE DESIGNArchitecturalConcepts By200 South Rangeline Rd. Suite 214 Carmel, IN 46032317.710.0939gnance@garynancedesign.com garynancedesign.comThese design concepts are the property of Gary Nance Designand may not be used without approval from Gary Nance DesignSCALE: 1/4"=1'-0"MAIN LEVEL FLOOR PLAN "C 2002 H. G. McCullough Designers, Inc. All rights reserved There shall be NO reproduction
of this work, its technical aspects or creative content without the express written consent
of H. G. McCullough Designers, Inc. This work is fully protected by copyright under
U.S. copyright law and is strictly enforced by H. G. McCullough Designer, Inc." 2Drawings & blueprints are intended solely as a plan layout& basis for materialestimate. H.G. McCullough Designers Inc.assumes no responsibility for structuralor material adequacy of drawings nor for compliance with appropriate building codes.H.G. McCullough Designers Inc. is not liable for, nor does it guarantee or controlcontractor or subcontractor's performance, nor their errors or omission. Customersshould have qualified engineer or architect review construction detailsSHEET NUMBER
11/23/22