Loading...
HomeMy WebLinkAboutFloor Plan 10-17EXISTINGFIREPLACETO REMAINW.C. L. SERVICE KITCHEN & PANTRY FREEZER 2'-6" 2'-6" 2'-6" SINK SHELVESFLOOR - CEILINGELEC. PANEL EXISTING WINDOW TO BE REMOVED. FRAME IN AS REQUIRED (VERIFY w/ CONTRACTOR) EXISTING WINDOW TO BE REMOVED. FRAME IN AS REQUIRED (VERIFY w/ CONTRACTOR) EXISTING WINDOW TO BE REMOVED. FRAME IN AS REQUIRED (VERIFY w/ CONTRACTOR) EXISTING WINDOW TO BE REMOVED. FRAME IN AS REQUIRED (VERIFY w/ CONTRACTOR) WORK STORAGE NOOK W. D.HANG ROD BOOR BENCH KEY DROP REPLACE EXISTINGFRENCH DOOR UNITNOTE: EXISTING DECK STRUCTURE AND CONCRETE TO BE REMOVED (VERIFY w/ CONTRACTOR) SINK EXISTING WINDOW TOBE REMOVED. FRAMEIN AS REQUIRED(VERIFY w/ CONTRACTOR)SPACE FOR FREEZER DOOR TO OPEN FULLY DRINK LEDGE 4'-0"5'-0" 6'8"x12'0" SLIDING GLASS DOOR UNIT BEAM EQUALLY SPACED BEAM EQUALLY SPACED BEAM EQUALLY SPACED BEAM EQUALLY SPACED ADD NEW BRICK (VERIFY w/ CONTRACTOR) ADD NEW BRICK (VERIFY w/ CONTRACTOR) W.C. L. W.C. MASTER BEDROOM MASTER BATHROOM SHOWER BATHROOM WALK-IN CLOSET WALK-IN CLOSET SHOWERSIT DOWNL. SEATING ROOM SHELF ABOVE SOFA SMALL BUILT-IN END TABLE BOOKS/ DISPLAY SMALL BUILT-IN END TABLE 84" SOFA BOOKS/ DISPLAY MEDIA LAUNDRY TALL CLEANING CABINET BEAM EQUALLY SPACED BEAM EQUALLY SPACED BEAM EQUALLY SPACED BEAM EQUALLY SPACED BEAMBEAMBEAMBEAMBEAMDINING AREA CLOSETCLOSETCLOSETCLOSETNEW COVERED PORCH 2 CAR GARAGE SERVICE ENTRY NOTE: GABLE TRUSS THAT SITS ON TOP OF CABINETS (VERIFY w/ CONTRACTOR AND GARY NANCE FOR DESIGN) CENTER OF RIDGE BEAM SLOPEDCEILINGSLOPEDCEILINGSLOPEDCEILINGSLOPEDCEILING- 8'0" CEILING HEIGHT (TO MATCH EXISTING) BEDROOM #2 3'0" x 6 ' 8 "2'6"x6'8"3'0"x6'8" POCKET DOOR 3'6"x6'8" CASED OPENING2'8"x6'8"POCKET DOOR2'6"x6'8" 2'4"x6'8" POCKET DOOR2'8 "x6'8"1'6"x6'8" PAIRDOORS2 '8"x6'8 "3'0"x6'8"POCKETDOOR2'0 "x6 '8 "2'8"x6'8"2'8"x6 '8" 2'8"x6'8" POCKET DOOR 2'8"x6'8" CASED OPENING 2'8"x6'8"SLIDINGSTYLE DOORCLOSETCLOSETEXISTING DOOR TO BE REMOVED. FRAME IN AS REQUIRED (VERIFY w/ CONTRACTOR) KITCHEN EXISTING WINDOW TO BE REMOVED. FRAME IN AS REQUIRED (VERIFY w/ CONTRACTOR)BUILT - INCABINETSBUILT - INCABINETSBUILT - INCABINETSBUILT - INCABINETS22'-7" FACE OF NEW SHEATHING 23'-0"10'-178"9'-1134"7'-4"11'-214"4'-034"2'-1038"15'-412"FACE OF EXISTINGSTUD FRAMING TO NEWSTUD FRAMING5'-6"23'-1112"16'-912"FACE OF BRICK(VERIFY w/ CONTRACTOR)4'-734"5'-1014"FACE OF BRICK (VERIFY w/ CONTRACTOR)3'-8"15'-8"FACE OF BRICK (VERIFY w/ CONTRACTOR)7'-212"VERIFY AT SITE12'-112"FACE OF BRICK (VERIFY w/ CONTRACTOR) 18'-312" EXISTING STRUCTURE BRICK TO BRICK 7'-10" 13'-0"9'-8" FACE OF SHEATHING (VERIFY w/ CONTRACTOR)46'-3"30'-6" 4" 14'-0" 512" 7'-512" 4" 4'-1" 312" 3'-4"312" 6'-212" 5'-7"312" 3'-1112"2'-8"2'-912"8'-7"912"512"13'-312"512"6'-2"312"3'-1112"1'-3"512"2'-212"4'-7"312"8'-1"4'-7"312"4'-1112" 2'-412"3'-5"312"4'-4"312"3'-5"4'-012"312"6'-7"512"5'-6" 8'-1"5'-812"7'-212"512"312"10'-8"312"7'-412"5'-812"312"5'-7"312"2'-6"4'-1"312"4'-7" 312"12'-8"3 12"2 STEPSDOWN TOGARAGE4'-1118" 8'-058" 8'-058" 8'-058" 4'-1118"FACE OF BRICK (VERIFY w/ CONTRACTOR) FACE OF BRICK (VERIFY w/ CONTRACTOR) ADD NEW BRICK (VERIFY w/ CONTRACTOR) 1'-41316"8'-0"1'-3"1'-0"101316" 8'-1138" 8'-058" 8'-058" 1'-41316" 101316" 8'-1138" 6'0"x6'8" DOOR UNIT 3'0"x6'8" 14" S.L.14" S.L. 6'0"x6'8" DOOR UNIT 6'0"x6'8" DOOR UNIT NEW 16'0"x7'0" GARAGE DOOR2'-712"312"FACE OF EXISTING STUD (VERIFY w/ CONTRACTOR)15'-012"REPLACE EXISTING WINDOWS (VERIFY WINDOW SPECS. AT SITE) REPLACE EXISTING WINDOWS (VERIFY WINDOW SPECS. AT SITE) REPLACE EXISTING WINDOWS (VERIFY WINDOW SPECS. AT SITE) 1 1 22 2844284428442444364436443660-3 2844-3 13'-0"3'0"x6'8"CASED OPENING1'-0" 4 4 4 43660 36602-PLYx111 4 LVL HDR. EXISTING BRICK TO BE REMOVED (VERIFY w/ CONTRACTOR) ADD NEW BRICK (VERIFY w/ CONTRACTOR) FLAT SOFFIT NOTE: GABLE TRUSS THAT SITS ON TOP OF CABINETS (VERIFY w/ CONTRACTOR AND GARY NANCE FOR DESIGN)BEAMBEAMBEAMBEAMBEAMGAS SINKLAYOUT AS PER KITCHEN DESIGNER MECHANICALS W/H SOFTENER FURNACE(EXISTING LOCATION)48"RANGE2'0"x6'8"2'0"x6'8"2'8 " x6'8 " WATER DISPENSER - 8'0" CEILING HEIGHT - 8'0" CEILING HEIGHT - 8'0" CEILING HEIGHT - 8'0" CEILING HEIGHT - 8'0" CEILING HEIGHT 3. GENERAL NOTES 2x10 BLOCKING FLUSH w/ INSIDE FACE OF STUDS 8" 5. WINDOW/DOOR HEAD FRAMING DETAIL (TYP.)6"CONSTRUCTION LEGEND 1. AREA LEGEND INTERIOR DIMENSIONS TO FACE OF STUD WALLS EXTERIOR DIMENSIONS TO FACE OF SHEATHING 4. DIMENSION NOTES LVL HEADER (VERIFY SIZING w/ LUMBER MANUFACTURER) 8'-0" CEILING HEIGHT UNLESS OTHERWISE NOTED. MATCH EXISTING CEILING HEIGHTS. VERIFY AT SITE w/ CONTRACTOR POCKET DOORS: TRIPLE 2x12 HEADER w/1 2" PLYWOOD GUSSETS 2 PLY SOLID BLOCKING BOTH SIDES (TYP.) VERIFY WINDOWS w/ OWNER/CONTRACTOR. MARVIN WINDOWS SHOWN, VERIFY WINDOW NUMBERS AND SIZING w/ WINDOW MANUFACTURER AFTER THIS IS COMPLETE. PLEASE PROVIDE H.G. McCULLOUGH DESIGNERS w/ A WINDOW LIST. FLOOR JOIST MANUFACTURERS ARE TO SUPPLY H.G. McCULLOUGH DESIGNERS w/ ALL NECESSARY FLOOR FRAMING PLANS, INCLUDING MAIN, SECOND AND ROOF PLAN. H.G. McCULLOUGH DESIGNERS IS TO BE NOTIFIED DURING THE FLOOR FRAMING DESIGN PROCESS IF IT DEVIATES FROM THE ORIGINAL PLAN. wE WILL REVIEW THE CHANGES w/ ONE ANOTHER. MAIN LEVEL FLOOR JOIST SYSTEM - 60 LBS. P.S.F. TOTAL FLOOR LOAD. PROVIDE SOLID BLOCKING BETWEEN FLOORS UNDER ALL BEARING WALLS AND COLUMNS ABOVE. ALL WALLS ALIGNED w/ FLOOR JOIST DIRECTION TO HAVE FLOOR JOIST BELOW. CONTRACTOR IS RESPONSIBLE FOR COMPLIANCE WITH CODES, ORDINANCES, AND REGULATIONS APPLICABLE TO THE PROJECT LOCATION. CONTRACTOR SHALL NOT SCALE DRAWINGS. IF ADDITIONAL INFORMATION IS REQUIRED TO CLARIFY THESE DOCUMENTS , THE CONTRACTOR SHALL CONTACT THE DESIGNER IMMEDIATELY. WHEN "APPROVED EQUAL" , "EQUAL TO", OR OTHER QUALIFYING TERMS ARE USED, IT SHALL BE BASED UPON THE REVIEW OF THE CONTRACTOR/OWNER'S. THE DESIGNER SHALL BE NOTIFIED OF MATERIALS BEING INSTALLED. DRAWINGS ESTABLISH THE DESIGN INTENT OF WORK TO BE PERFORMED. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE HIGHEST INDUSTRY STANDARDS. ALL PRODUCTS SHALL BE INSTALLED BY THE CONTRACTOR IN ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS/RECOMENDATIONS. ANY DISCREPANCIES OR CONFLICTS SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE DESIGNER AND THE OWNER PRIOR TO FABRICATION OR INSTALLATION. CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD VERIFYING EXISTING CONDITIONS AND FOR VERIFYING THEM WITH THE DRAWINGS. ANY DISCREPANCY IN THE DRAWINGS AND SPECIFICATIONS SHALL BE BROUGHT TO THE NOTICE OF THE DESIGNER PRIOR TO ANY FABRICATION OR CONSTRUCTION. CONTRACTOR SHALL PROVIDE ALL NECESSARY REQUIRED PLANS TO ALL SUB-CONTRACTORS. BEARING WALLS 2. MATERIALS LEGEND - REMODEL CONSTRUCTION NEW FRAME WALLS BRICK VENEER EXISTING WALLS WALLS TO BE REMOVED EXISTING MAIN: MAIN LEVEL 2395 SQUARE FEET EXISITNG CAR GARAGE: 540 SQUARE FEET NEW MAIN: 350 SQUARE FEET Date: 10-14-2022Plan number #220802Designed For:Perkins & RoseH. G. McCULLOUGH DESIGNERS, INCCONSTRUCTION DRAWINGS BY:- 2146 Glenview Drive, Evansville, IN 47720 - Email: designers@hgmccullough.com- Telephone: 812 . 428 . 0174- www.hgmccullough.comGARY NANCE DESIGNArchitecturalConcepts By200 South Rangeline Rd. Suite 214 Carmel, IN 46032317.710.0939gnance@garynancedesign.com garynancedesign.comThese design concepts are the property of Gary Nance Designand may not be used without approval from Gary Nance DesignSCALE: 1/4"=1'-0"MAIN LEVEL FLOOR PLAN "C 2002 H. G. McCullough Designers, Inc. All rights reserved There shall be NO reproduction of this work, its technical aspects or creative content without the express written consent of H. G. McCullough Designers, Inc. This work is fully protected by copyright under U.S. copyright law and is strictly enforced by H. G. McCullough Designer, Inc." 2Drawings & blueprints are intended solely as a plan layout& basis for materialestimate. H.G. McCullough Designers Inc.assumes no responsibility for structuralor material adequacy of drawings nor for compliance with appropriate building codes.H.G. McCullough Designers Inc. is not liable for, nor does it guarantee or controlcontractor or subcontractor's performance, nor their errors or omission. Customersshould have qualified engineer or architect review construction detailsSHEET NUMBER 11/23/22