HomeMy WebLinkAboutA-01 Site Plan and Wall Section (1)(2) 2x12 HDR
(2) 2x12 HDR
SEE FLOOR PLANS AND WALL SECTION
FOR TOP PLATE HEIGHTS
SEE FLOOR PLANS FOR
HEADER HEIGHTS
KING AND JACK STUDS
DOOR
WDW
SEE FLOOR PLAN AND SECTION NOTES
FOR SPECIFIC UNIQUE BEAM SIZES
1 2 '-0 "
5 '-9 "13'
-0"N 3'-0"9'-1 1/8" ADJUST AS REQUIRED TO PROPERLY FLASH BELOW 2ND FLOOR WINDOW2'-8" MIN BELOW GRADE1/2" ROOF SHEATHING
2 LAYERS OF 30# ROOFING FELT
FIBERGLASS SHINGLES
INSTALLED ACCORDING TO
MANUFACTURER'S SPECIFICATIONS
FOR A LOW-SLOPE APPLICATION
ICE AND WATER MEMBRANE
METAL DRIP EDGE
GUTTER
2x8 SUB FASCIA
1x8 FASCIA
3/8" VENTILATED SOFFIT
12
MINIMUM 2
18" DIAMETER
CONCRETE PIER
VENTILATED POST ANCHOR
6x6 PRESSURE
TREATED POST
COMPOSITE FASCIA
BOARD SKIRTING
LINE OF EXISTING
FINISHED FLOOR
TRIPLE 2x10 P.T. BEAM
WITH JOIST HANGERS
FOOTING TO BEAR ON
UNDISTURBED SOIL
NOTE:
STRUCTURE IS TO BE SELF-
SUPPORTING.
DO NOT BEAR ON EXISTING
BRICK VENEER
2x10 PRESSURE-TREATED
JOISTS AT 16" ON CENTER
COMPOSITE DECKING
2x8 RAFTERS AT 16" O.C.
4x4 PRESSURE-TREATED POST
1 1/2" RIGID INSULATION SANDWICHED
BETWEEN 1/4" CEMENTITIOUS PANELS
AND TRIMMED WITH 1x3 SMART TRIM
2x2 FRAMING AT
16" ON CENTER
1x SMART TRIM OVER
INSECT SCREENING
1x TRIM WRAPPING
STRUCTURAL HEADER
Description
Architectural
Site Plan
Sheet Number
A-01C2022 SURROUNDINGSTHIS PLAN IS PROPERTY OFSURROUNDINGS.ANY UNAUTHORIZED USE ORREPRODUCTION OF THIS PLAN, INWHOLE OR IN PART ISPROHIBITED. SURROUNDINGSWILL USE ALL LEGAL MEANSAVAILABLE TO PURSUE THEUNAUTHORIZED USE OF THISPLAN OR ANY DESIGN ELEMENTSCONTAINED THEREIN.Sottong ResidenceCovered PorchYorktown Woods - Section 1 - Lot 212647 Highmount Court Carmel, Indiana 46033Date
10.21.22 Indiana Design Center200 S. Rangeline Road Suite 120A Carmel, Indiana 46032Architectural Site Plan
SCALE: 1" = 20'-0"
SLOPE GRADE TO
DRAIN AWAY FROM
STRUCTURE
LOCATION OF NEW
SCREEN PORCH
Typical Door and Window Framing
SCALE: 1/4" = 1'-0"
Area Location Map
NO SCALE
PROPOSED
SQUARE FOOTAGE TABLE
SFGARAGE672
SFDRIVEWAY948
PROPOSED SCREEN PORCH SF156
SF
SF
SECOND FLOOR
FIRST FLOOR 1,231
1,211
SFBASEMENT (FINISHED AND UNFINISHED)1,231
SFLOT6,300
Typical Wall Section
SCALE: 1/2" = 1'-0"
GENERAL NOTES:
THE BUILDER SHALL VERIFY THAT SITE CONDITIONS ARE
CONSISTENT WITH THESE PLANS BEFORE STARTING WORK. WORK
NOT SPECIFICALLY DETAILED SHALL BE CONSTRUCTED TO THE
SAME QUALITY AS SIMILAR WORK THAT IS DETAILED. ALL WORK
SHALL BE DONE IN ACCORDANCE WITH INTERNATIONAL BUILDING
CODES AND LOCAL CODES.
WRITTEN DIMENSIONS AND SPECIFIC NOTES SHALL TAKE
PRECEDENCE OVER SCALED DIMENSIONS AND GENERAL NOTES.
THE ENGINEER/DESIGNER SHALL BE CONSULTED FOR
CLARIFICATION IF SITE CONDITIONS ARE ENCOUNTERED THAT ARE
DIFFERENT THAN SHOWN, IF DISCREPANCIES ARE FOUND IN THE
PLANS OR NOTES, OR IF A QUESTION ARISES OVER THE INTENT OF
THE PLANS OR NOTES. CONTRACTOR SHALL VERIFY AND IS
RESPONSIBLE FOR ALL DIMENSIONS (INCLUDING ROUGH
OPENINGS).
11/29/22