HomeMy WebLinkAboutA001.0 - FoundationIndiana Division11590 North Meridian Street, Suite 530Carmel, Indiana 46032PLAN NAME SHEET PRODUCTION MANAGER DATE / DESCRIPTION NPC PLAN NUMBERLAWSON PLAN ID GARAGE HANDING REV # NOTE: SCALES NOTED ON DRAWINGS RELATE TO FULL SIZE PLOTS ON 22x34 SHEETS - 11x17 SHEETS REPRESENT 1/2 SCALE PLOTS INITIAL RELEASE DATE:CURRENT RELEASE DATE: (c) Copyright Pulte Home Corporation - 2022 Zach Bittner07/30/2021 RIGHT SUMMERFIELD 2009.300 51004 05/17/2022 PLOTTED: August 30, 2022 / Waseem Ansari / 2009-SUMMERFIELD-MZ-BASE-PLAN.DWG A0 BB-1.1Basement Foundation Plan w/ Masonry Wrap.\A1;1'-0" SCALE:BASEMENT FOUNDATION PLAN1/4" = 1'-0"- BASEMENT - UNFINISHEDSLAB (SEE STRUCTURAL PLANS) 2B.2 2B.2 1B.1 1B.1 SLOPE CONCRETE SLABUNEXCAVATED (SEE STRUCTURAL PLANS) HAD 6.3 EAD 5.4 CONCRETE SLABUNEXCAVATED (SEE STRUCTURAL PLANS) CONCRETE SLABUNEXCAVATED (SEE STRUCTURAL PLANS) PROVIDE 10' MIN. SEPARATION BETWEEN WATER AND SEWER LINES, PER CODE SUMP w/ CHECK VALVE, VERIFY LOCATION IN FIELD PERIMETER DRAIN,\PPER SPEC FURNACE, PER SPEC. VERIFY LOCATION w/ MECHANICAL PLANSWATER HEATER, PER SPEC. VERIFY LOCATION IN FIELD FLOOR DRAIN, \PVERIFY LOCATION RADON VENT PER CODE, VERIFY LOCATION\A1;66'-7" - OVERALL \A1;66'-7" - OVERALL \A1;38'-7" - OVERALL \A1;1'-9{\H0.75x;\S1#2;}"\A1;16'-3" \A1;49'-7" LEAD WALL PAST OVERDIG, FIELD VERIFY LOCATION (TYP.) \A1;26'-3" \A1;23'-4" \A1;1'-9{\H0.75x;\S1#2;}"\A1;19'-10" \A1;18'-3" 4140 SL & EGRESS WELL #3, AS REQUIRED BY CODE\PSEE STRUCTURAL AND ARCHITECTURAL DETAILS\PA/E ON SHEET A.D 4.5 \A1;10'-9{\H0.75x;\S1#2;}" UP 16\P\pxql;RISERS\pxql;1\pxql;2\pxql;3\pxql;4\pxql;5\pxql;6\pxql;7\pxql;8 HANDRAIL, \PPER CODE\pxql;10 \A1;10'-9{\H0.75x;\S1#2;}"\A1;9'-7{\H0.75x;\S1#2;}"\A1;18'-2"\A1;8'-8{\H0.75x;\S1#2;}" \A1;3'-8" \A1;3'-8" \A1;12'-3{\H0.75x;\S1#2;}" \A1;7'-4" \A1;3'-8"\pxql;9 ROUGH IN \PBATH \A1;2'-11{\H0.75x;\S1#2;}"\A1;2'-11"\A1;19'-9{\H0.75x;\S1#2;}"\A1;11'-1{\H0.75x;\S1#2;}"\A1;7'-6"\A1;8'-4" POST & BEAM PER STRUCTURAL PLANS LEAD WALL PAST OVERDIG, FIELD \PVERIFY LOCATION (TYP.) \A1;38'-7" - OVERALL \A1;5'-0" \A1;25'-11"\A1;12'-8" \A1;2'-3{\H0.75x;\S1#2;}"\A1;6'-3{\H0.75x;\S1#2;}" \A1;5'-8{\H0.75x;\S1#2;}" \A1;11'-3{\H0.75x;\S1#2;}" \A1;2'-0"\A1;2'-0"\A1;3'-5"\A1;2'-0"\A1;8'-2"\A1;2'-0"\A1;6'-0{\H0.75x;\S1#2;}"\A1;2'-0"\A1;3{\H0.75x;\S1#2;}" LEAD WALL PAST OVERDIG, FIELD VERIFY LOCATION (TYP.) \A1;5'-8{\H0.75x;\S1#2;}" \A1;4'-0" \A1;19'-9" \A1;54'-3{\H0.75x;\S1#2;}" \A1;10'-0"LEAD WALL PAST OVERDIG, FIELD VERIFY LOCATION (TYP.) \A1;18'-3"\A1;14'-4" \A1;3{\H0.75x;\S1#2;}"\A1;3{\H0.75x;\S1#2;}" SQUARE FOOTAGES BASE HOUSE - HEATED FIRST FLOOR 1489 SECOND FLOOR 1323 TOTAL BASE HEATED 2812 BASE HOUSE - UNDER ROOF GARAGE - 2 CAR REAR ENTRY 515 BASEMENT 1430 COVERED PATIO 182 FRONT PORCH 193 TOTAL BASE UNDER ROOF 3327 LIGHT & VENT SCHEDULE ROOM NAME AREA (SF) LIGHT 8%VENT 4%MECH (CFM) REQ ACT REQ ACT REQ ACT KITCHEN / CAFE / GATHERING 626.02 50.1 68.5 25.0 29.5 ------ FLEX 124.16 9.9 27.4 5.0 11.8 ------ FLEX 2 155.46 12.4 27.4 6.2 11.8 ------ PPC 51.85 4.1 8.5 2.1 3.4 ------ PR 29.11 2.3 8.3 1.2 3.6 ------ O. SUITE 226 18.1 23.4 9.0 11.8 ------ O. BATH 99.71 8.0 2.0 4.0 ---103.7 80 BEDROOM 2 157.15 12.6 23.4 6.3 11.8 ------ BEDROOM 3 161.75 12.9 23.4 6.5 11.8 ------ LAUNDRY 41.88 3.4 ---1.7 ---43.6 60 LOFT 143.53 11.5 23.4 5.7 11.8 ------ BEDROOM 7 164.33 13.1 11.9 6.6 6.5 ------ BATH 7 45.92 ------------53.7 60{\Fsimplex|c0;\W0.7;* ARTIFICIAL LIGHT AND/OR MECHANICAL VENTILATION SUPPLIED\P** BATH FAN REQ: LxWxH OF ROOM x 0.13 = MIN. CFM RATING REQUIRED\PTHE TABLE ABOVE SHOWS CALCULATIONS THAT APPLY FOR ALL ELEVATIONS, U.N.O.} 11/30/22