Loading...
HomeMy WebLinkAbout06060146 Site Plan ~., Schneider Note: This drawing is based an construction plans or record drawings, and is not based upon a field survey. The Schneider Corporation does not warrant the accuracy or sufficiency of this information. Contractors should verify existing conditions prior to any construction. Any discrepancy found on this drawing should be reported to The Schneider Corporation immediately; failing to do so results in the contractors assumption of ali liability. Note: Plot Pion legend The basement elevation, depicted hereon, has been determined [2QM] Proposed Grades and based upon the pad grades and/or contours token from the 000.0 Existing Grades construction plans for this subdivision. Unless stated, no ______ 000.0- Contour Grade information about fluctuating water tables, sail conditions, or sail * Approx. Lateral Location types has been provided or stated on said pions. It is - . - Sanitary Sewer Lines recommended that the basement finished floor elevations be at - BT - Storm Sew~r Li~es least tv/a feet (2') above the normal pool elevotion of any - IJ - Water SerVIce Lln,es . odpining bodies of water, unless 0 study of facts reveals - - - .- - - - Sub-Surface .oroln Lines otherwise. If during the excavation process any ground water is Manhole (Sanitary or Storm) witnessed The Schneider Corporation should be notified II Beehive inlet (Storm) . .' . . 11III Curb Inlet (Storm) Immediately. The basement elevotlon should be raISed two feet D End Section (Storm) (2') above the ground water, and additional construction ... Fire Hydrant techniques should be incorporated to alle~ote future problems. - 0 0 0 - 0 0 0 - Flow Line of swale Tbe Sc1melder CorponlUon 8901 aU! Avenue Historic fort. Harrison Indianapolis, Indiana 48216-1037 3t7-8211-71oo 317-828-7200 FAX Engineering 3urveyiDg Lanucape Archilecture GIS .IJS GtIo1ogy Flood Hazard Statement: The accuracy of any flood hazard data shown on this plot pion is sub jeet to mop scole uncertainty and to any other uncertainty in locotion or elevation on the referenced flood insurance rate mote (FIRM). None of the within described land lies within that special flood hazard zone "A", os said land plots by scale on Community Map Panel # 18057C 0026 F of the flood insurance rate mops (FIRM) for the city of Carmel, Hamilton County, Indiana, Dated February 19, 20DJ ~ This Plot Plan Prepared For: Trinity/Beazer Homes Lot # 15 , containing 6,250 S.F.f, in Yorktown Woods Section # 1 Instrument # 200600017282 C.O.C. # 200600023419 P.C. # 4, Slide # 48 Hamilton County, Clay Township Section 19, Township 18 N, Range 4 EAST 2612 Millgate Court (50' R/W) Carmel, IN 46074 Prepared Date: 06-06-06 : By. MBK Community Restrictions: Side Yard = 6' (BH) Rear Yard = 20' Zonin9 = ROSO III Finished Floor Elevation Information Pad Grade = 832.6 per plan Pod Grode + 0.33' = Garage FFE (832.93) Garage FFE + 1.04' = Residential FFE (833.97) Residential FFE - 9.0 ' = Basement FFE (824.97) Note: The garage finished floor elevation is 1.5' above the curb at the drive, per plan. Ground Cover Calculations: Drive = 885 SF f Public Walk = 218 SF f Privote Walk = 12 SF f Rear Yard = 1,773 SFf Sod = 192 Sri , from rear of home. NOTE: IN THE RESIDENTIAL DISTRICTS L1MI1lNG HEIGHT TO TWENTY-FIVE (2S) FEET. A DWELLING MAYBE INCREASED IN HEIGHT TO THIRTY-FIVE (3S) FEET PROVIDED THE SlOE AND REAR YAROS ARE INCREASEO AN ADOl1l0NAL FOOT FOR EACH FOOT SUCH STRUCTURE EXCEEDS TWENTY-FIVE (2S) FEET IN HEIGHT. PER CARMEL ZONING ORDINANCE 26.1.1. ~ T'fPICAL SWALE SECTION FLOOD HAZARD STATEMENT CERTIFICATION ,\1\\\\\11111111111I1/1///1. #"c: L />~ij~ is'~\.';) 'VjOh~ ~ "-~, .........."...'r'{f:J~ ~<.V~'i ....r_\STE"A';:.... ~A~ ~ ~~"'-'U N ".",....::::::: ~<:::::),"Q;-v 0 0',,;,.0'% i ( 50303 ) j ~ ". STATE OF ... $f \~......!.IvDIA~':.../~i % '4tJ "S""U"ii~i \' ~ ,# ~//, 1\ '1 \..~~~ 1/1""/ll/llillll\\\\\lII\ '\J'-l,~ Note: Sanitary Sewer Top of Casting Information Upstream Manhole, TC= 832.00 Downstream Manhole, TC= 832.S0 Per Plan LOT # 15 VB # 06.0055565 Note: The contractor is to maintain o minimum distance of ten feet (10') between the sanitary sewer and water line laterals, Note: Sump pump(s) to be placed by builder as needed. ~ Note: Builder to ensure positive drainage away from structure(s). o ~ =li3.= o Assumed North ~O SCALE 1" = 30' -- oJ'/-'" 1'c;J.. REVISION # 1 ADD BRICK SIDES & REAR VB#06.0055905 06-12-06 MBK PLEASE NOTE THAT THE STRAIGHT UNE SLOPE OF THE ORIVEWA Y FROM THE GARAGE RNISHED FLOOR ELEVATION TO THE TOP OF THE CURB AT THE CENTER OF THE DRIVEWAY EXCEEOS 5X AS PROPOSED. THIS SlOPE IS BASEO ON THE REQUiRED MINIMUM GARAGE RNISHED FLOOR ELEVATION AND THE EXISTING TOP OF CUR8 ELEVATION.