Loading...
HomeMy WebLinkAbout06060180 State Release Would you like to reduce your turnaround time? ELECTRONICALLY FILE YOUR PROJECT WITH STATE OF INDIANA AT efile24w7@dhs.state.in.us, Or VISIT OUR WEB SITE AT www.in.gov/dhs/osbc Project number Release dale CONSTRUCTION DESIGN RELEASE Stale Form 41191 (R9/S-98) Report Printed on: June 12. 2006 318871 Construction type V-B 06/12/06 B Indiana Department of Homeland Security DIVISION OF FIRE SAFETY I PLAN REVIEW 402 W. Washington St., Room E245 Indianapolis, IN 46204 INDIANA 02 , ~ 0000 Scope of release FDN STR Type of release Standard Project name Family Physicians of Carmel HOOSIER SAFETY Available At Your Local Licence Branch To: Owner I Architect I Engineer R E Thomason and Associates PC Richard Thomason 03978 6990 Hillsdale Ct Indianapolis IN 46250 SUPPORT HOOSIER SAFETY Street address 310 Medical Dr City County HAMILTON fax & e-mail: 3179132155, rethomason@aol.com l The plans, specifications and application submitted for the above referenced project have been reviewed for compliance with the applicable rules of the Fire Prevention and Building Safety Commission. The project is released for construction subject to, but not necessarily limited to, the conditions Iisted'below..;rHIS 'IS' NOTA'BU ILDING'PERMtT':'AIt required'local'permits and'licenses must be obtained'prior to'beginning'construction work. All <;:'onstruction work must be in full compliance with all applicable State rules. Any changes in the released plans and/or specifications'jmust be filed with and released by this Office before any work is'~ltered.i:rhis:';releaSerTl<.:lY be:~uspended'or revoked if it is determ!ned"to bel is~ued in: error, in violation 9f any rules of the Commission or if it is base{oq i.nc~rrecCor insu~icient informa~ion~'iThis release shall expire bY'limitation, and become null and void, if the work authorized is not commenced within on'e (1);year from'the above date: ' , ' > CONDITIONS: " ',' - '," ,', ' Carmel ~ote :(A 1A & A 1 B): In acco~dance:":Vi!h;the affidavit sworn under penalties of perjury in the application for construction design release the plans and specifications filed in conjunction with this project shall comply with all of the applicable rules and laws of Fire Prevention and Building Safety Commission. Providing false infonnation constitutes an act of perjury, which is a Class 0 felony punishable by a prison term and a fine up to $10,000. \ ...... . "' ! ' l,n accordance with Secti~n19 of the General Administrative Rules (675 lAC 12-6~19) a complete set of plans and specifications that conform exactly to the design that was released by the office of the state building commissioner sh~lIl be maintained on the construction jobsite as well as a copy of the design release. " . 1 i ", , , I i4G0615A Thisi~,iq)artially submitted and released project. Subsequent submittals shall be accompanied by a "completed standard / partial form (ACDR) and proper fees in accordance with 675 lAC 12-6-15(c). .J ". '" ~. ,"" I Every stairway serving any building or portion thereof shall conform to the requirements of Section ,1003.3.3, IBC (675 lAC 13-2.4) ,3B1003Q 1 ' " 13B1208B,.' A 20-inch by 40-inch attic access opening shall be provided in accordance with Section 1208.2, IBC (675 lAC 13-2A). I Adequate attic ventilation shall be provided in accordance with Section 1202.2, IBC (675 lAC 13-2.4). !3B 1202A 3B0716A Draft stops shall be installed in accordance with Section 716.4, IBC (675 lAC 13-2.4). 3C0502H1 For a slab-on-grade floor, the perimeter insulation shall extend downward from the top of the slab to the top of the inverted tee of a spread footing in accordance with Section 502.3.1.4, IECC (675 lAC 19-3-1). Please be advised that if an administrative review of this action is desired, a written petition for review must be filed at the above address with the Fire Prevention and Building Safety Commission identifying the matter for which a review is sought no later than eighteen (18) days from the above- stated date, unless the eighteenth day falls on a Saturday, a Sunday, a legal holiday under State statute, or a day in which the Department of Fire and Building Services is closed during normal business hours. In the latter case, the filing deadline will be the first working day thereafter. If you choose to petition, and the before-mentioned procedures are followed, your petition for review will be granted, and an administrative proceeding will be conducted by an administrative law judge of the Fire Prevention and Building Safety Commission. If a petition for review is not filed, this Order will be final, and you must comply with its requirements. Page 1/2 Filed By Code review official Code Enforcement & Plan Review Branch Director ROBIN PHilLIPS v~d/S~ Address (name, title of local official,street,city,state and ZIP code DEPT OF COMMUNITY SERVICE State Fire Marshal V1arO~ JIM BLANCHARD ONE CIVIC SQUARE CARMEL, IN 46032 Fax & e-mail: 3175712499,jblanchard@carmel.in.gov Would you like to reduce your turnaround time? ELECTRONICALLY FILE YOUR PROJECT WITH STATE OF INDIANA AT efile24~7@dhs.state.in.us, Or VISIT OUR WEB SITE AT www.in.gov/dhs/osbc Page 2/2