HomeMy WebLinkAbout06060209 Signed Conditional ENCOMPASS NOTEPAD - 07/06/06 NOTES FOR: 06060209 BLDG 1 - PR DATE TIME NOTE TEXT rcONDfT'or~AL 2006-07-06 17:15:56 CONDITIONAL RELEASE PLAN REVIEW ITEMS: (Per William Hohlt) 1. Show 4 foot ~erimeter insulation around exterlor. 2. Show length of anchor bolts into concrete. 3. Show method of attaching canteliever at back decks. 4. Need size of beams and girders. 5. Need floor and roof truss calculations. --All notes apply to lots 1A-1C & 2A-2F. ***** Per Building Commissioner: The above items must be addressed and resolved :;~:a~~Roug)Ln. i~:~m"Y be Slgn~ Name prlnted Date TOTAL LINES OF NOTES: 25 PAGE 1 OPERATOR slillard