HomeMy WebLinkAbout06060212 State Release
Would you like to reduce your turnaround time?
ELECTRONICALLY FILE YOUR PROJECT WITH STATE OF INDIANA AT
etlle24-7@dhs.state.ln.us, Or VISIT OUR WEB SITE AT www.ln.gov/dhs/osbc
Project number
CONSTRUCTION DESIGN RELEASE
Stale Form 41191 (R9/5-98)
Report Printed on: June 19, 2006
Indiana Department of Homeland Security
DIVISION OF FIRE SAFETY / PLAN REVIEW
402 W. Washington St, Room E245
Indianapolis, IN 46204
INDIANA 02
~1QAQPO
Available At. Your Loe,l Licence Branch
SUPPORT HOOSIER SAFETY
To: Owner I Architect J Engineer
Bruce Gunstra Bulders Inc
Robert R Grove 18369
8383 Craig St Suite 100
Indianapolis IN 46250
318860
Construction type
V-B
Scope of release
ARCH ELEC FDN
PLUM STR
Type of release
Standard
Project name
Monon and Main
Bulding 2
Street address
Monon
Release date
06/19/06
Occupancy classification
TOWNHOUSE
MECH
City
CARMEL
County
HAMILTON
Fax & e-mail: 3175952161,
The plans, specifications and application submitted for the above referenced project have been reviewed for compliance with the applicable rules of
the Fire Prevention and Building Safety Commission. The project is released for construction subject to, but not necessarily limited to, the conditions
Iisted'below."THIS 'IS'NOT-ABU IlDING'PERMIT;-AlI'required'local' pennits'and'licenses' mustbe'obtained'prior to'beginning'construction work. All
construction work must be in full compliance with all applicable State rules. Any changes in the released plans and/or specificationsimust be filed with
~nd released by this Offic~ ~efore ~~y. wo~ i~'i3~e~e,ct.\T,his{1,~e~~~se .~-,a,y ~'~psp~nd~,'9r revoked if it is detenn\ned,'!p ~~]s.~lled in: error, in violation
of any rules of the Commission or If It IS baseaion Incorrect 9f Insufficlellt mfonnatlon: Jt)is release shall expire by lim_I!Stion"and become null and
void, if the work authorized is not commenced;~thjri ori'e ,q),ye,* fro'm:t~e ~bOve:da{e.,' \ 1. C ,\ .s'
CONDITIONS: ' ,:" \_"t L,.:,:,iiOw' L,' ~,! '''' 1,"' 'd~ h, " c;
Note :(A1A & A1B): In accordanceY:lit~\the affidavit.swom under penalties of perjury in the application fOfconstruction design feleas~ the plans
and specifications filed in oonjunction:with this project shall comply with 'aliaf the applicabie,rules,and laws'of Fh'e Prevention and Building Safety
Commission. Providing f~l_seinfonnatio:noonstitutesl~l},.~ct of p,e~ury, whiCh\is a 91ass D felony:punishabl~ ,~y ~ ~rison term ,and a fine up to $10,000.
(n accordance with S~ctro,n 19 of t~e G?neral Adm)ntlstratiVe R~le:s (675 I~C \1 ~-,6;-19) a cOf!1ple:te:set of pl~ns and specifications that conform
exactly to the design'that was released by the offiCe of the state building commissioner shall be maintained,on the construdion jobsite as well as a
copy of the desig.~ relef.;lse.; . ~ . , . " " ~
.,,-,'. , ,'< .," , . ",!,j
1 :This,projecrhas beeni~viewed urider 2005 lridiana Resideritial CoCle.
;';t '
.2.:.A.t~wnh()use Is a single-f~mily. awelling :unlt :constructedi,n a group,of three or mo(e attached
uilits'separted by property:lines inwhich'each unit eXtends'fromJoundation,to roof and with open
'space on at least two sides in accordance with Section R202,IRC(675 lAC 14-4-3). i
Permitted openings'b",tween the:garage. ?nd'residenceshall be equipped with solid wood, or solid
or honeycomb fore;;s!e~I~:~o~rs,"not,,!ess.'!hah, 11'3/8; iriches thick or 20-minute fire-rated doors in
___~~!~.1'~~th Sec~o'n R309.1;IRC (675IACJ.i-4;2)~______________,________j
4. The area of garage floors used for parking of automobiles or other vehicles shall be sloped to
facilitate the movement of liquids to an approved drain or toward the main vehicle entry doorway in
accordance with Section R309.1 IRC (675 lAC 14-4-2).
5. Porches,balconies,decks or raised floor surfaces located more than 30 inches above the floor or
graade beiow shall have guarrails not iess than 36 inches in height in accordance with Section
R312.11RC (675 lAC 14-4-2).
Townhouses shall be separated by two one-hour fire-resistive walls or one two-hour fire-resistive
wall with parapets in accordance with Section R321, IRC (675 lAC 14-4.2).
Townhouses separated by two one-hour fire-resistive walls shall be structurally independent in
accordance with Section R321.2.4, IRC (675 lAC 14-4.2).
A complete street address or similar description shall be furnished in accordance with 675 lAC 12-6-
6(c)(2).
'100309A
100321A
100321B
4G0606AH
Page 1/2
Would you like to reduce your turnaround time?
ELECTRONICALLY FILE YOUR PROJECT WITH STATE OF INDIANA AT
eflle24-7@dhs.state.ln.us, Or VISIT OUR WEB SITE AT www.ln.gov/dhsJosbc
Please be advised thai if an administrative review of this action is desired, a written petition for review must be tiled at the above address with the
Fire Prevention and Building Safety Commission identifying the matter for which a review is sought no later than eighteen (18) days from the above -
stated date, unless the eighteenth day falls on a Saturday, a Sunday, a legal holiday under State statute. or a day in which the Department of Fire
and Building Services is closed during normal business hours. In the latter case, the filing deadline will be the first working day thereafter. If you
choose to petition, and the before-mentioned procedures are followed, your petition for review wilt be granted, and an administrative proceeding will
be conducted by an administrative law judge of the Fire Prevention and Building Safety Commission. If a petition for review is not filed, this Order will
be final, and you must comply with its requirements.
Filed By Code review official Code Enforcement & Plan Review Branch Director
PATRICIA CRAYTON ~~d/S~
Address (name,title of local official,street,city,state and ZIP code
DEPT OF COMMUNITY SERVICE State Fire Marshal V1?,O~
JIM BLANCHARD
ONE CIVIC SQUARE
CARMEL, IN 46032
Fax & e-mail: 3175712499,jblanchard@carmel.in.gov
t,
f:i:1
I,
11t;
i
I.~:
. ,or'