Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Lighting Design
PROJECT SUMMARY Not to be reproduced in whole or part without the written consent of Musco Sports Lighting, LLC. ©1981, 2022 Musco Sports Lighting, LLC.ENGINEERED DESIGN By: Joe Seda · File #224190A · 12-Dec-22 Woodland Country Club Carmel, IN USA LighƟng System Pole / Fixture Summary Pole ID Pole Height Mtg Height Fixture Qty Luminaire Type Load Circuit T1 60'60'1 TLC-LED-1200 1.17 kW A 60'2 TLC-LED-900 1.78 kW A T2 60'60'3 FUTURE 2.95 kW B 60'1 TLC-LED-1200 1.17 kW A 60'2 TLC-LED-900 1.78 kW A T3 60'60'3 FUTURE 2.95 kW B 3 12 11.80 kW Circuit Summary Circuit Description Load Fixture Qty A North Courts 5.9 kW 6 B South Courts 5.9 kW 6 Fixture Type Summary Type Source Wattage Lumens L90 L80 L70 Quantity TLC-LED-900 LED 5700K - 75 CRI 890W 89,600 >120,000 >120,000 >120,000 4 TLC-LED-1200 LED 5700K - 75 CRI 1170W 136,000 >120,000 >120,000 >120,000 2 Light Level Summary Calculation Grid Summary IlluminationGrid Name Calculation Metric Ave Min Max Max/Min Ave/Min Circuits Fixture Qty North Courts 150' Spill_Candela Max Candela (by Fixture)176 0 667 0.00 A 6 North Courts 150' Spill_Vertical fc Max Vertical Illuminance Metric 0.01 0 0.04 0.00 A 6 Pickleball Horizontal Illuminance 33.8 22 41 1.86 1.53 A 6 Tennis 1 Horizontal Illuminance 34.4 22 42 1.87 1.57 A 6 ILLUMINATION SUMMARY Not to be reproduced in whole or part without the written consent of Musco Sports Lighting, LLC. ©1981, 2022 Musco Sports Lighting, LLC.ENGINEERED DESIGN By: Joe Seda · File #224190A · 12-Dec-22 22 29 38 39 34 30 37 38 33 36 38 37 29 34 42 67'81'58'37' T2 T1 IRR IRR D D SCALE IN FEET 1 : 30 0'30'60' EQUIPMENT LIST FOR AREAS SHOWN Pole Luminaires QTY LOCATION SIZE GRADE ELEVATION MOUNTING HEIGHT LUMINAIRE TYPE QTY / POLE THIS GRID OTHER GRIDS1T160'-60' 60' TLC-LED-1200 TLC-LED-900 1 2 1 2 0 0 1 T2 60'-60' 60' TLC-LED-900 TLC-LED-1200 2 1 2 1 0 0 2 TOTALS 6 6 0 Pole locaƟon(s)dimensions are relaƟve to 0,0 reference point(s) Woodland Country Club Carmel, IN USA GRID SUMMARY Name: Tennis 1 Size: 1 Court - 12' Spacing Spacing: 20.0' x 20.0' Height: 3.0' above grade ILLUMINATION SUMMARY MAINTAINED HORIZONTAL FOOTCANDLES EnƟre Grid Guaranteed Average:30 Scan Average:34.44 Maximum:42 Minimum:22 Avg / Min:1.53 Guaranteed Max / Min:2.5 Max / Min:1.87 UG (adjacent pts):0.00 CU:0.32 No. of Points:15 LUMINAIRE INFORMATION Applied Circuits: A No. of Luminaires: 6 Total Load: 5.9 kW Guaranteed Performance:The ILLUMINATION described above is guaranteed per your Musco Warranty document and includes a 0.95 dirt depreciaƟon factor. Field Measurements:Individual Įeld measurements may vary from computer-calculated predicƟons and should be taken in accordance with IESNA RP-6-15. Electrical System Requirements:Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing. InstallaƟon Requirements:Results assume ± 3% nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locaƟons. ILLUMINATION SUMMARY Not to be reproduced in whole or part without the written consent of Musco Sports Lighting, LLC. ©1981, 2022 Musco Sports Lighting, LLC.ENGINEERED DESIGN By: Joe Seda · File #224190A · 12-Dec-22 IRR IRR D D 34 37 37 37 37 37 35 30 26 37 41 41 34 29 26 22 67'33'58'85' T2 T1 SCALE IN FEET 1 : 30 0'30'60' EQUIPMENT LIST FOR AREAS SHOWN Pole Luminaires QTY LOCATION SIZE GRADE ELEVATION MOUNTING HEIGHT LUMINAIRE TYPE QTY / POLE THIS GRID OTHER GRIDS1T160'-60' 60' TLC-LED-1200 TLC-LED-900 1 2 1 2 0 0 1 T2 60'-60' 60' TLC-LED-900 TLC-LED-1200 2 1 2 1 0 0 2 TOTALS 6 6 0 Pole locaƟon(s)dimensions are relaƟve to 0,0 reference point(s) Woodland Country Club Carmel, IN USA GRID SUMMARY Name: Pickleball Size: 30' x 120' Spacing: 15.0' x 15.0' Height: 3.0' above grade ILLUMINATION SUMMARY MAINTAINED HORIZONTAL FOOTCANDLES EnƟre Grid Guaranteed Average:30 Scan Average:33.75 Maximum:41 Minimum:22 Avg / Min:1.53 Guaranteed Max / Min:2.5 Max / Min:1.86 UG (adjacent pts):1.43 CU:0.19 No. of Points:16 LUMINAIRE INFORMATION Applied Circuits: A No. of Luminaires: 6 Total Load: 5.9 kW Guaranteed Performance:The ILLUMINATION described above is guaranteed per your Musco Warranty document and includes a 0.95 dirt depreciaƟon factor. Field Measurements:Individual Įeld measurements may vary from computer-calculated predicƟons and should be taken in accordance with IESNA RP-6-15. Electrical System Requirements:Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing. InstallaƟon Requirements:Results assume ± 3% nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locaƟons. ILLUMINATION SUMMARY Not to be reproduced in whole or part without the written consent of Musco Sports Lighting, LLC. ©1981, 2022 Musco Sports Lighting, LLC.ENGINEERED DESIGN By: Joe Seda · File #224190A · 12-Dec-22 0.02 0.03 0.01 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.01 0.00 0.04 0.03 0.02 0.02 0.020.030.030.010.000.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.01 0.01 0.01 0.01 0.01 0.01 0.02 T2 T1 IRR IRR D IRR IRR IRR IRRIRR IRR IRR IRR IRR IRR IRR D T3 SCALE IN FEET 1 : 60 0'60'120' EQUIPMENT LIST FOR AREAS SHOWN Pole Luminaires QTY LOCATION SIZE GRADE ELEVATION MOUNTING HEIGHT LUMINAIRE TYPE QTY / POLE THIS GRID OTHER GRIDS1T160'-60' 60' TLC-LED-1200 TLC-LED-900 1 2 1 2 0 0 1 T2 60'-60' 60' TLC-LED-900 TLC-LED-1200 2 1 2 1 0 0 2 TOTALS 6 6 0 Pole locaƟon(s)dimensions are relaƟve to 0,0 reference point(s) Woodland Country Club Carmel, IN USA GRID SUMMARY Name:North Courts 150' Spill_VerƟcal fc Spacing: 30.0' Height: 3.0' above grade ILLUMINATION SUMMARY MAX VERTICAL FOOTCANDLES EnƟre Grid Scan Average:0.0081 Maximum:0.04 Minimum:0.00 No. of Points:44 LUMINAIRE INFORMATION Applied Circuits: A No. of Luminaires: 6 Total Load: 5.9 kW Guaranteed Performance:The ILLUMINATION described above is guaranteed per your Musco Warranty document. Field Measurements:Individual Įeld measurements may vary from computer-calculated predicƟons and should be taken in accordance with IESNA RP-6-15. Electrical System Requirements:Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing. InstallaƟon Requirements:Results assume ± 3% nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locaƟons. ILLUMINATION SUMMARY Not to be reproduced in whole or part without the written consent of Musco Sports Lighting, LLC. ©1981, 2022 Musco Sports Lighting, LLC.ENGINEERED DESIGN By: Joe Seda · File #224190A · 12-Dec-22 667 642 248 1 0 0 0 1 1 0 0 0 14 57 30 18 260 548 522 553 58565159417600 0 10 12 0 0 0 2 35 48 14 15 88 182 194 197 342 456 601 T2 T1 IRR IRR D IRR IRR IRR IRRIRR IRR IRR IRR IRR IRR IRR D T3 SCALE IN FEET 1 : 60 0'60'120' EQUIPMENT LIST FOR AREAS SHOWN Pole Luminaires QTY LOCATION SIZE GRADE ELEVATION MOUNTING HEIGHT LUMINAIRE TYPE QTY / POLE THIS GRID OTHER GRIDS1T160'-60' 60' TLC-LED-1200 TLC-LED-900 1 2 1 2 0 0 1 T2 60'-60' 60' TLC-LED-900 TLC-LED-1200 2 1 2 1 0 0 2 TOTALS 6 6 0 Pole locaƟon(s)dimensions are relaƟve to 0,0 reference point(s) Woodland Country Club Carmel, IN USA GRID SUMMARY Name: North Courts 150' Spill_Candela Spacing: 30.0' Height: 5.0' above grade ILLUMINATION SUMMARY CANDELA (PER FIXTURE) EnƟre Grid Scan Average: 176.4354 Maximum:667.11 Minimum:0.00 No. of Points:44 LUMINAIRE INFORMATION Applied Circuits: A No. of Luminaires: 6 Total Load: 5.9 kW Guaranteed Performance:The ILLUMINATION described above is guaranteed per your Musco Warranty document. Field Measurements:Individual Įeld measurements may vary from computer-calculated predicƟons and should be taken in accordance with IESNA RP-6-15. Electrical System Requirements:Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing. InstallaƟon Requirements:Results assume ± 3% nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locaƟons. EQUIPMENT LAYOUT Not to be reproduced in whole or part without the written consent of Musco Sports Lighting, LLC. ©1981, 2022 Musco Sports Lighting, LLC.ENGINEERED DESIGN By: Joe Seda · File #224190A · 12-Dec-22 Tennis 1 1 Court - 12' Spacing T2 T1 IRR IRR D IRR IRR IRR IRRIRR IRR IRR D Pickleball 30' x 120' Tennis 2-3 2 Court - 12' Spacing T3 SCALE IN FEET 1 : 50 0'50'100' Pole locaƟon(s)dimensions are relaƟve to 0,0 reference point(s) Woodland Country Club Carmel, IN USA EQUIPMENT LAYOUT INCLUDES: · Pickleball · Tennis 1 · Tennis 2-3 Electrical System Requirements:Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing. InstallaƟon Requirements:Results assume ± 3% nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locaƟons. EQUIPMENT LIST FOR AREAS SHOWN Pole Luminaires QTY LOCATION SIZE GRADE ELEVATION MOUNTING HEIGHT LUMINAIRE TYPE QTY / POLE 1 T1 60'-60' 60' TLC-LED-1200 TLC-LED-900 1 2 1 T2 60'-60' 60' TLC-LED-900 TLC-LED-1200 2 1 1 T3 60'- 3 TOTALS 6 SINGLE LUMINAIRE AMPERAGE DRAW CHART Ballast SpeciĮcaƟons (.90 min power factor) Line Amperage Per Luminaire (max draw) Single Phase Voltage 208 (60) 220 (60) 240 (60) 277 (60) 347 (60) 380 (60) 480 (60) TLC-LED-900 5.3 5.0 4.6 4.0 3.2 2.9 2.3 TLC-LED-1200 7.0 6.6 6.1 5.2 4.2 4.0 3.0