Loading...
HomeMy WebLinkAboutKMX_Indianapolis_IN_GFS_Permit_Package_CompleteCarMax/GFSEquipmentPermitBooklet (GFSRefinishEquipmenttobeinstalledinKMXFacility.)  Store:CarMaxIndianapolis.  Address:9750NorthGrayRd/Indianapolis,IN46280.   SectionI.)EquipmentLayout&Position  A.) GFSRefinishEquipmentGeneralLayout&General ArrangementdrawingsfortheCosmeticBuilding.  RefinishEquipmentBuildingPermitInformation All3rdPartyEngineeringFirmListingReportsby ETL(IntertekTestingServices)&UL(Underwriters Laboratory)  SectionII.)OSHA–IntertekNRTLCertificate  SectionIII.)DowndraftUltraSprayBooths  A.) PaintSprayBooth/ATMReport#101579520CRTͲ001 B.) IndustrialControlPanel/ULListingReport#E138868 C.) IndustrialHeater/ATMReport#104185893CRTͲ001 D.) SprayBoothLightFixture/ATMReport#3080616ͲH01  SectionIV.):PaintMixingRoom  A.)PaintMixRoom/ATMReport#100690377CRTͲ001 B.)SprayBoothLightFixture/SameasSprayBooth      10/25/22   GFSEquipmentPermitBookletCon’t (GFSRefinishEquipmenttobeinstalledinFacility.)  SectionV.)AdvanceCure  A.) AdvanceCure/ATMReport#104156083CRTͲ001  NOTES.)RefinishEquipmentMechanical/ElectricalPermitInformation  NOTE#1:AllMainElectricalPowerSupplyfromthebuildingfor theGFSRefinishEquipmentControlPanelstobePermittedand completedbyGeneralContractorsLicensedElectrical SubContractor.  NOTE:AllGasSupply&CompressedAirsupplyforGFSRefinish Equipmenttobecompleted&permittedbyGeneral ContractorsLicensedsubͲcontractor.  NOTES.)GFSRefinishEquipmentFireSystem/AlarmPermitInformation.  NOTE#1:AllFireSuppressionSystemsforGFSRefinishEquipment tobePermittedandcompletedbyGeneral ContractorsLicensedsubͲcontractor.  NOTE#2:AllElectricalRequirementsfortheGFSRefinishEquipment FireSuppressionSystemstobePermittedandcompleted byGeneralContractorsLicensedsubcontractor.   GFSAuto/TruckRefinishDivision:877.658.7900 10/25/22 LEGCONTROL PANEL1'-0 5/16"14'-5"6'-2 1/2"4'-0 11/16"15'-0"12'-5"LIGHTLIGHTESIGNED DRAWING(S) IS A STATEMENT THAT THE DIMENSIONS, DESIGNAND APPLICATION HAVE BEEN REVIEWED AND ARE APPROVEDFOR FABRICATION.MANUFACTURE OF EQUIPMENT WILL BE SCHEDULED AFTER RECEIPT OFAPPROVED DRAWINGS.AUTHORIZED SIGNATURE:REQUIRED INFORMATIONGAS PRESSURE:VOLTAGE:PHASE:ROOF PITCH:GFS WILL NOT BE RESPONSIBLE FOR BACK CHARGES WHEN INFORMATIONPROVIDED IS INCORRECT.CUSTOMER APPROVAL of DRAWINGSVALUECUSTOMER VERIFICATIONYESOTHER:YESOTHER:YESOTHER:YESOTHER:APPROVED AS SUBMITTED DISAPPROVED - PLEASE RESUBMITINFOGFS STANDARD CONTROL PANEL S.C.C.R.:5KA RMSNANANA14 inwcREVISION HISTORYREVDATEREFERENCEBYDESCRIPTIONGFS EQUIPMENT CONSTRUCTION NOTE:1. GAS SUPPLY REQUIRED (BY OTHERS) TO GAS CONNECTION POINT (G). MINIMUM GAS PRESSURE IS REQUIRED AT MAXIMUM VOLUME CONSUMED. MINIMUM CIRCUIT CAPACITY IS REQUIRED (BY OTHERS) TO CONNECTION POINT (E). LIGHTING CIRCUIT IS REQUIRED (BY OTHERS) TO CONNECTION POINT (L).2. THE EQUIPMENT DEPICTED IN THIS DRAWING HAS NOT BEEN APPROVED FOR OUTDOORAPPLICATIONS. IN THE EVENT THAT SUCH APPLICATIONS AND/OR USES ARE CONTEMPLATED,THE PURCHASER OF THE EQUIPMENT IS RESPONSIBLE FOR NOTIFYING GFS SO THATADDITIONAL STRUCTURAL ANALYSIS CAN BE PERFORMED AND THE NECESSARYMODIFICATIONS CAN BE DETERMINED.3. DUCT SUPPORT NOT SUPPLIED OR DESIGNED BY GFS. EQUIPMENT IS NOT DESIGNED TO SUPPORT DUCT. DUCT SUPPORTS SHALL BE DESIGNED TO RELIEVE THE EQUIPMENT OF ALL DUCT LOAD.ULTRA XDMIX ROOM12'L x 6'W x 9'H INSIDEBULTRA XD BOOTH27'L x 14'W x 9'H INSIDEAA B C D E1234GLOBAL FINISHING SOLUTIONS12731 NORWAY ROADOSSEO, WI 54758 USA800-848-8738 globalfinishing.comIMPORTANT NOTE: This print and all information contained therein is the sole property of GlobalFinishing Solutions, LLC ("GFS"). It is not to be used or reproduced in any manner or submitted toother parties for examination without the express written approval of GFS pursuant to a fully-executedcontract or purchase order for GFS-manufactured equipment. Customer may make and retain copies ofthe print for information and reference in connection with an equipment order; however, this print isnot intended or represented to be suitable for re-use by Customer or others on extensions of the orderor on any other project. Any use without written verification is at Customer's sole risk and withoutliability to GFS, its affiliates, or agents.© Global Finishing Solutions, LLCDRAWINGDRAWING SETREVISIONORDER/SERIAL NUMBERSCALEDRAWN BYDATEREVIEW BYREVIEW DATEMODEL INFOSOLD TOSHIP TOCARMAX12800 TUCKAHOE CREEK PARKWAYRICHMOND, VA 232381115CARMAX 7144 INDIANAPOLIS9750 NORTH GRAY RDINDIANAPOLIS, IN 46280U143126DSAGLGENERAL LAYOUTGFS EQUIPMENT1/4" = 1'-0"AJE6/16/2022DAT6/16/20222022AIR HEATERMAX AIRFLOWRATE(CFM)INTAKE /EXHAUSTMOTOR(HP)FUELMAXFIRINGRATE(BTU/HR)MIN INLETPRESS. AT MAXFIRING RATE(INWC)MAXINLETPRESS.(PSI)TEMP.RISE(°F)INLET PIPESIZE NPT(IN)1254110 / 10NATURALGAS144000011.35.01021PROPANE 11250005.080MOTOR MINIMUM CIRCUIT CAPACITYMOTOR SPECIFICATIONSFULL LOAD AMP DRAW /MINIMUM CIRCUIT CAPACITY10HP INTAKE, 10HP EXHAUST230V 1PH 208V 3PH 230V 3PH 480V 3PH 575V 3PHINTEGRATED ADVANCE CURE(4) 1HP ADVANCE CURE MOTORS83.0 /104.0LIGHTING CIRCUITQUANTITY OFLIGHTFIXTURES(4-TUBE,6-TUBE, STDOR LED)SINGLE PHASEMINIMUM CIRCUITCAPACITY (AMPS)120V277V143020ABELECTRICAL REQUIREMENTSELECTRICALDEVICEMOTORFULL LOAD AMPDRAWMINIMUM CIRCUITCAPACITYEXHAUST FAN &INTAKE FANFAN MOTOR(EACH)1/2HP, 120V, 1PH9.830 AMPLIGHT FIXTURES120V / 277V1.0 / 0.5 (EACH)10/25/22 NRTLPOccupational Safety and Health AdministrationNationally Recognized Testing Laboratory Program Certificate of Recognition Intertek Testing Services NA, Inc.with headquarters at:545 East Algonquin Road, Suite FArlington Heights, IllinoisUnited States is recognized by the Occupational Safety and Health Administration (OSHA) as meeting the requirements for a NationallyRecognized Testing Laboratory (NRTL) established under Section 1910.7 of Title 29, Code of Federal Regulations. Thisrecognition is limited to testing and certification only within the current scope of recognition and is subject to all other terms setforth in the letter of recognition and in applicable Federal Register notices and as summarized on OSHA’s website. Thisrecognition continues in force beyond the “Effective through” date below provided the NRTL has filed a timely request for renewalwith OSHA. For current recognition status and other recognition information, contact the OSHA NRTL Program or visithttps://www.osha.gov/dts/otpca/nrtl/ March 5, 2026 Effective Through Amanda L. EdensDeputy Assistant Secretary of Labor forOccupational Safety and Health Administration 10/25/22 AUTHORIZATION TO MARK Applicant: Manufacturer: Address:Address: Country:Country: Contact:Contact: Phone:Phone: FAX:FAX: Email:Email: Standard(s): Product: Brand Name: Models: This Authorization to Mark is for the exclusive use of Intertek's Client and is provided pursuant to the Certification agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Authorization to Mark. Only the Client is authorized to permit copying or distribution of this Authorization to Mark and then only in its entirety. Use of Intertek’s Certification mark is restricted to the conditions laid out in the agreement and in this Authorization to Mark. Any further use of the Intertek name for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. Initial Factory Assessments and Follow up Services are for the purpose of assuring appropriate usage of the Certification mark in accordance with the agreement, they are not for the purposes of production quality control and do not relieve the Client of their obligations in this respect. Intertek Testing Services NA Inc. 545 East Algonquin Road, Arlington Heights, IL 60005 Telephone 800-345-3851 or 847-439-5667 Fax 312-283-1672 Standard for Spray Application Using Flammable or Combustible Materials [NFPA 33:2017 Ed.2018] Standard for Exhaust Systems for Air Conveying of Vapors, Gases, Mists, and Particulate Solids [NFPA 91:2014 Ed.2015] Canadian Electrical Code Part I: Safety Standard For Electrical Installations [CSA C22.1:2015 Ed.23] Spray Booth PFPDP, PFMDP, PFMMP, PFVDP, PFVMP, PFXDP, PFXDN, PFXMP, PFXMN, PFXSP, PFXSN, PFXCP, PFXCN, PXVDP, PXVMP, PFSDP, PFSDN, PFSMP, PFSMN, PFSSP, PFSSN, PFSCP, PFSCN ULPDP, ULTDP, UTFDP, USVDP, UTVDP, FTKDP, PRFDP, PRFMP, PTFDP, PTFMP, PSVDP, PSVMP, PTVDP, PTVMP, VTXDP, VTXDN, VTXMP, VTXMN, VTXSP, VTXSN, VTXCP, VTXCN, CTFDP, CTFMP, VTVDP, VTVMP, CTVDP, CTVMP GPCDG, GPDDG, GPSMG, GPSDG, GPCDW, GPDDW, GPSMW, GPSDW, GPCDWI, GPDDWI, GPSMWI, GPSDWI GFS Control Number: 3088468 Authorized by: for L. Matthew Snyder, Certification Manager This document supersedes all previous Authorizations to Mark for the noted Report Number. wmcfadden@globalfinishing.com bbertolini@globalfinishing.com bbertolini@globalfinishing.com wmcfadden@globalfinishing.com Party Authorized To Apply Mark: Same as Manufacturer Report Issuing Office: Intertek Testing Services NA, Inc., Cortland, NY William McFadden Bo Bertolini Bo Bertolini William McFadden 1-800-848-8738 ext 4013 1-800-848-8738 ext 8227 1-800-848-8738 ext 8227 1-800-848-8738 ext 4013 NA NA Global Finishing Solutions LLC Global Finishing Solutions LLC 12731 Norway Road, P.O Box 250 Osseo, WI 54758 12731 Norway Road, P.O Box 250 Osseo, WI 54758 USA USA This authorizes the application of the Certification Mark(s) shown below to the models described in the Product(s) Covered section when made in accordance with the conditions set forth in the Certification Agreement and Listing Report. This authorization also applies to multiple listee model(s) identified on the correlation page of the Listing Report. This document is the property of Intertek Testing Services and is not transferable. The certification mark(s) may be applied only at the location of the Party Authorized To Apply Mark. for L Matthew Snyder Certification Manager s NA, Inc., Cortland, NY Page 1 of 1 ATM for Report 101579520CRT-001 ATM Issued: 4-Oct-2021 ED 16.3.15 (16-Oct-2021) Mandatory10/25/22 10/25/22 10/25/22 10/25/22 10/25/22 10/25/22 AUTHORIZATION TO MARK Applicant: Manufacturer: Address:Address: Country:Country: Contact:Contact: Phone:Phone: FAX:FAX: Email:Email: Standard(s): Product: Brand Name: Models: Global Finishing Solutions LLC Global Finishing Solutions LLC 12731 Norway Rd. P.O. Box 250 Osseo, WI 54758 12731 Norway Rd. P.O. Box 250 Osseo, WI 54758 USA USA Mr. Andrew Marum Mr. Andrew Marum (715) 597-8092 (715) 597-8092 (715) 597-8292 (715) 597-8292 amarum@globalfinishing.com amarum@globalfinishing.com Party Authorized To Apply Mark: Same as Manufacturer Report Issuing Office: Cortland, NY 13045 Control Number: 3088468 Authorized by: for L. Matthew Snyder, Certification Manager This document supersedes all previous Authorizations to Mark for the noted Report Number. This Authorization to Mark is for the exclusive use of Intertek's Client and is provided pursuant to the Certification agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Authorization to Mark. Only the Client is authorized to permit copying or distribution of this Authorization to Mark and then only in its entirety. Use of Intertek’s Certification mark is restricted to the conditions laid out in the agreement and in this Authorization to Mark. Any further use of the Intertek name for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. Initial Factory Assessments and Follow up Services are for the purpose of assuring appropriate usage of the Certification mark in accordance with the agreement, they are not for the purposes of production quality control and do not relieve the Client of their obligations in this respect. Intertek Testing Services NA Inc. 545 East Algonquin Road, Arlington Heights, IL 60005 Telephone 800-345-3851 or 847-439-5667 Fax 312-283-1672 Direct Gas-Fired Process Air Heaters [ANSI Z83.25:2015 ] Direct Gas-Fired Process Air Heaters [CSA 3.19:2015 Ed.2] Direct Fired Gas Heater for use in Paint Booth Applications AHFD2400 followed by -D, -H or -V, AHRC2400 followed by -D, -H or -V, BT1200FD, BT1200RC and GUL2000 Spacesaver and BT/GUL This authorizes the application of the Certification Mark(s) shown below to the models described in the Product(s) Covered section when made in accordance with the conditions set forth in the Certification Agreement and Listing Report. This authorization also applies to multiple listee model(s) identified on the correlation page of the Listing Report. This document is the property of Intertek Testing Services and is not transferable. The certification mark(s) may be applied only at the location of the Party Authorized To Apply Mark. Page 1 of 1 ATM for Report 104185893CRT-001 ATM Issued: 2-Mar-2021 ED 16.3.15 (15-Oct-20) Mandatory10/25/22 10/25/22 10/25/22 AUTHORIZATION TO MARK Applicant: Manufacturer: Address:Address: Country:Country: Contact:Contact: Phone:Phone: FAX:FAX: Email:Email: Standard(s): Product: Models: Control Number: Lake Forest, CaReport Issuing Office: Party Authorized To Apply Mark: Same as Manufacturer jmarcinkowski@globalfinishing.com John Marcinkowski USA 715 597 8227 Dual Skin Models: UMR410, UMR421, UMR432, UMR443, UMR454, UMR465, UMR324; UMR335, UMR346, UMR450, UMR346, UMR353, UMR313, UMR357, UMR368, UMR216, UMR227, UMR238, UMR350. Single Skin-Models: VMR fb 69, 99, 912, 915, 612, 1212, 615; VEST1502, VEST1001. Paint Mix Room, Single Skin, Double Skin Negative Pressure, Positive Pressure ventilation Models. This document supersedes all previous Authorizations to Mark for the noted Report Number. NFPA-33 (2011 Edition) Spray Application Using Flammable or Combustible Materials. NFPA-91 (1999 Edition) Standard for Exhaust Systems for Air Conveying of Vapors, Gases, Mists and Noncombustible Particulate Solids, Paint Spray Booths and Drying Ovens, CR90 -003 1992. This Authorization to Mark is for the exclusive use of Intertek's Client and is provided pursuant to the Certification agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Authorization to Mark. Only the Client is authorized to permit copying or distribution of this Authorization to Mark and then only in its entirety. Use of Intertek’s Certification mark is restricted to the conditions laid out in the agreement and in this Authorization to Mark. Any further use of the Intertek name for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. Initial Factory Assessments and Follow up Services are for the purpose of assuring appropriate usage of the Certification mark in accordance with the agreement, they are not for the purposes of production quality control and do not relieve the Client of their obligations in this respect. Intertek Testing Services NA Inc. 165 Main Street, Cortland, NY 13045 Telephone 800-345-3851 or 607-753-6711 Fax 607-756-6699 John Marcinkowski jmarcinkowski@globalfinishing.com Global Finishing Solutions 12731 Norway Road P.O Box 250, Osseo, WI 54758 12731 Norway Road P.O Box 250, Osseo, WI 54758 USA Global Finishing Solutions William T. Starr, Certification Manager 715-597 8027 Authorized by:3088468 715-597 8027 715 597 8227 This authorizes the application of the Certification Mark(s) shown below to the models described in the Product(s) Covered section when made in accordance with the conditions set forth in the Certification Agreement and Listing Report. This authorization also applies to multiple listee model(s) identified on the correlation page of the Listing Report. This document is the property of Intertek Testing Services and is not transferable. The certification mark(s) may be applied only at the location of the Party Authorized To Apply Mark. ATM for Report 100690377CRT-001 Page 1 of 1 ATM Issued: 12-Sep-2012 ED 16.3.15 (18-Jun-12) Mandatory10/25/22 AUTHORIZATION TO MARK Applicant: Manufacturer: Address:Address: Country: Country: Contact:Contact: Phone:Phone: FAX:FAX: Email:Email: 202136 1 Standard(s): Product: Brand Name: This Authorization to Mark is for the exclusive use of Intertek's Client and is provided pursuant to the Certification agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Authorization to Mark. Only the Client is authorized to permit copying or distribution of this Authorization to Mark and then only in its entirety. Use of Intertek’s Certification mark is restricted to the conditions laid out in the agreement and in this Authorization to Mark. Any further use of the Intertek name for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. Initial Factory Assessments and Follow up Services are for the purpose of assuring appropriate usage of the Certification mark in accordance with the agreement, they are not for the purposes of production quality control and do not relieve the Client of their obligations in this respect. Intertek Testing Services NA Inc. 545 East Algonquin Road, Arlington Heights, IL 60005 Telephone 800-345-3851 or 847-439-5667 Fax 312-283-1672 Standard for Spray Application Using Flammable or Combustible Materials [NFPA 33:2017 Ed.2018] Canadian Electrical Code Part I: Safety Standard For Electrical Installations [CSA C22.1:2015 Ed.23] AdvanceCure Towers AdvanceCure Control Number: 3088468 Authorized by: for L. Matthew Snyder, Certification Manager This document supersedes all previous Authorizations to Mark for the noted Report Number. wmcfadden@globalfinishing.com bbertolini@globalfinishing.com bbertolini@globalfinishing.com wmcfadden@globalfinishing.com Party Authorized To Apply Mark: Same as Manufacturer Report Issuing Office: Intertek Testing Services NA, Inc., Cortland, NY William McFadden Bo Bertolini Bo Bertonlini William McFadden 1-800-848-8738 ext 4013 1-800-848-8738 ext 8227 1-800-848-8738 ext 8227 1-800-848-8738 ext 4013 715-597-8092 715-597-8092 Global Finishing Solutions LLC Global Finishing Solutions LLC 123731 Norway Rd Osseo, WI 54758 123731 Norway Rd Osseo, WI 54758 USA USA This authorizes the application of the Certification Mark(s) shown below to the models described in the Product(s) Covered section when made in accordance with the conditions set forth in the Certification Agreement and Listing Report. This authorization also applies to multiple listee model(s) identified on the correlation page of the Listing Report. This document is the property of Intertek Testing Services and is not transferable. The certification mark(s) may be applied only at the location of the Party Authorized To Apply Mark. thew Snyder Certification Man nd, NY Page 1 of 2 ATM for Report 104156083CRT-001 ATM Issued: 29-Jul-2021 ED 16.3.15 (5-Jun-2021) Mandatory10/25/22 AUTHORIZATION TO MARK Models: AC followed by I; followed by R001N, R001B, R012N, R012B, R023N, R034N, R034B, R045N, R045B, R210N or R210B; followed by T3T, T1D or T35. AC followed by R; followed by C001N, C012N, C023N, E034N, I045N, I056N, E067N, R078N, E089N, R100N or E111N; followed by T3T, T1D or T35. AC followed by M; followed by I001N; followed T3T, T1D or T35. Page 2 of 2 ATM for Report 104156083CRT-001 ATM Issued: 29-Jul-2021 ED 16.3.15 (5-Jun-2021) Mandatory10/25/22