HomeMy WebLinkAboutState CDRELECTRONICALLY FILE YOUR PROJECT WITH STATE OF INDIANA at http://www.in.gov/dhs/2650.htm.
This on-line filing is through a secure site, you can use it to submit your project information, pay the fees and upload your project plans.
Use Internet Browser to View this report, other browsers are not compatible to view this report
Page 1/2
CONSTRUCTION DESIGN RELEASE
State Form 41191 (R9/5-98)
Report Printed on: October 11, 2022
Project number Release date
433446 10/11/22
Construction type Occupancy classification
Scope of release
II-B, SPK B, S-1, REM
Type of release
Project name
Street address
City County
ARCH ELEC FDN MECH
Paint BoothPLUM STR
Standard
Carmax Paint Booth Replacement
9750 Gray Rd
CARMEL HAMILTON
To: Owner / Architect / Engineer
Carmax - Jarad Earley
12800 Tuckahoe Creek Parkw ay
Richmond VA 23238
Note :(A1A & A1B): In accordance w ith the affidavit sw orn under penalties of perjury in the application for construction design release the plans
and specifications filed in conjunction w ith this project shall comply w ith all of the applicable rules and law s of Fire Prevention and Building Safety
Commission. Providing false information constitutes an act of perjury, w hich is a Class D felony punishable by a prison term and a fine up to $10,000.
The plans, specifications and application submitted for the above referenced project have been review ed for compliance w ith the applicable rules
of the Fire Prevention and Building Safety Commission. The project is released for construction subject to, but not necessarily limited to, the
conditions listed below . THIS IS NOT A BUILDING PERMIT. All required local permits and licenses must be obtained prior to beginning construction
w ork. All construction w ork must be in full compliance w ith all applicable State rules. Any changes in the released plans and/or specifications must
be filed w ith and released by this Office before any w ork is altered. This release may be suspended or revoked if it is determined to be issued in
error, in violation of any rules of the Commission or if it is based on incorrect or insufficient information. This release shall expire by limitation, and
become null and void, if the w ork authorized is not commenced w ithin one (1) year from the above date.
CONDITIONS:
14B
4G0412AE
4G0603AF
14W1104A
14W240432
14W24044A
14W24047
9E51112
14M0306
NOTE: This release is for a Spray / Paint Booth.
This project has been review ed under the 2014 Indiana Building Code.
The proposed building, addition, or remodel shall not put the existing building in noncompliance or into
further noncompliance in accordance w ith 675 IAC 12-4-12.
Detailed plans and specifications for the revised fire suppression system shall be filed w ith the
required application and appropriate fees in accordance w ith 675 IAC 12-6- 3(a), 675 IAC 12-6-
7(g)(17), and 675 IAC 13-1-8. (N.F.P.A. 13)
Required means of egress shall be maintained during construction and demolition, remodeling or
alterations and additions to any building, in accordance w ith Section 1104, IFC (675 IAC 22-2.5).
The design and construction of spray booths shall be in accordance w ith Section 2404.3.2, IFC (675
IAC 22-2.5).
Spray booths and spray rooms shall be protected by an approved automatic fire-extinguishing system
in accordance w ith Section 2404.4 and Chapter 9, IFC (675 IAC 22-2.5).
Spray booths and spraying rooms shall be mechanically ventilated in accordance w ith Section
2404.7, IFC (675 IAC 22.2.5).
Where electrical portable hand tools or portable lighting is used GFCI protection shall be provided in
accordance w ith Section 511.12, IEC (675 IAC 17-1.8).
Access and service space for equipment and appliances shall be in accordance w ith Section 306,
IMC (675 IAC 18-1.6).
Indiana Department of Homeland Security
DIVISION OF FIRE & BUILDING SAFETY
PLAN REVIEW DIVISION
402 W. Washington St., Room E245
Indianapolis, IN 46204
Fax & e-mail:
SUPPORT HOOSIER SAFETY
Available At Your Local Licence Branch
In accordance w ith Section 19 of the General Administrative Rules (675 IAC 12-6-19) a complete set of plans and specifications that conform
exactly to the design that w as released by the office of the state building commissioner shall be maintained on the construction jobsite as w ell as a
copy of the design release.
, chris_baker@carmax.com
10/25/22
ELECTRONICALLY FILE YOUR PROJECT WITH STATE OF INDIANA at http://www.in.gov/dhs/2650.htm.
This on-line filing is through a secure site, you can use it to submit your project information, pay the fees and upload your project plans.
Use Internet Browser to View this report, other browsers are not compatible to view this report
Page 2/2
4G0603AR
14W2404325
4G0412AD
4G0607AR
4G0412AD
AREL
4G03
This release does not include all scopes of construction w ork. Plans and specifications for adding or
remodeling other systems shall be filed as a new project or as one or more partials before
commencing w ork in accordance w ith 675 IAC 12-6-3.
A clear space of not less than 3 feet shall be maintained on all sides of the spray booth in accordance
w ith Section 2404.3.2.5, IFC (675 IAc 22-2.5).
NOTE: Electrical w iring and equipment located outside of, but w ithin 5 feet (1524 mm) horizontally
and 3 feet (914 mm) vertically of openings in a spray booth or a spray room, shall be approved for
Class I, Division 2 or Class II, Division 2 hazardous locations, w hichever is applicable in accordance
w ith Section 2403.2.1.3, IFC.
Minor nonstructural repairs to an existing building w hich do not affect any structural members or any
part of the building having a required fire resistance may be made w ith the same materials of w hich
the building is constructed in accordance w ith 675 IAC 12-4-12(g).
Plans and specifications for the paint spray booth fire-suppression system shall be filed in accordance
w ith 675 IAC12-6-3(a) and 7(g)(l7).
Minor nonstructural repairs to an existing building w hich do not affect any structural members or any
part of the building having a required fire resistance may be made w ith the same materials of w hich
the building is constructed in accordance w ith 675 IAC 12-4-12(g).
Pursuant to 675 IAC 12-6-21, the issuance of a design release does not relieve the ow ner from
required compliance w ith all applicable rules of the commission, even if noncompliant conditions
appear in the plans and specifications that have been filed w ith the division. The ow ner is responsible
for correcting any and all areas of noncompliance even if they are discovered subsequent to the
issuing of this design release.
This construction design is a revised release to the release dated: 10/07/2022 (change of local /
city jurisdiction)
Please be advised that if an administrative review of this action is desired, a w ritten petition for review must be filed at the above address w ith the
Fire Prevention and Building Safety Commission identifying the matter for w hich a review is sought no later than eighteen (18) days from the above
-stated date, unless the eighteenth day falls on a Saturday, a Sunday, a legal holiday under State statute, or a day in w hich the Department of Fire
and Building Services is closed during normal business hours. In the latter case, the filing deadline w ill be the first w orking day thereafter. If you
choose to petition, and the before-mentioned procedures are follow ed, your petition for review w ill be granted, and an administrative proceeding
w ill be conducted by an administrative law judge of the Fire Prevention and Building Safety Commission. If a petition for review is not filed, this
Order w ill be final, and you must comply w ith its requirements.
Code review official
Address (name,title of local official,street,city,state and ZIP code
LARRY DAVIS
CJ Taylor
One Hamilton Square
Suite 306
Noblesville, IN 46060
Director
Fax & e-mail: , cj.taylor@hamiltoncounty.in.gov
Indiana State Building Commissionerldavis2@dhs.in.gov
10/25/22