Loading...
HomeMy WebLinkAboutSD A GA ULTRA XD DOWNDRAFT BOOTH14'-0"WORKING WIDTH27'-0" WORKING LENGTH 12'-9 7/8"6'-2"27'-5" OVERALL LENGTH 14'-5"OVERALL WIDTH20'-7"OVERALL17'-7 1/4" ∅34" EXHAUST ∅34" INTAKE (QTY 6) 6-TUBE LED, CLASS 1 DIV 2, INSIDE-ACCESSIBLE LIGHT FIXTURES IN BOOTH SIDE WALLS. PLAN VIEWREAR ELEVATION LH SIDE ELEVATION RH SIDE ELEVATION FRONT ELEVATION CLEARANCE REQUIRED AROUND AIR HEATER: 36" IN FRONT OF CONTROL PANEL 24" IN FRONT OF FILTER DOOR 18" IN FRONT OF EXHAUST MOTOR ANY DEVICE LOCATED WITHIN 3' OF DOOR OPENINGS MUST BE LISTED FOR CLASS 1, DIVISION 2. WIRING INSTALLATION TO THE DEVICE MUST MEET THE REQUIREMENTS FOR A CLASS 1, DIVISION 2 LOCATION. BLADE ADVANCECURE SYSTEM (QTY 4): SYSTEM IS INTERLOCKED WITH SPRAY BOOTH CONTROL PANEL AND IS NON-FUNCTIONAL DURING PAINT SPRAY CYCLE. 19' BLDG ROOF (REF) PERSONNEL DOOR WITH WINDOW 2'-8" X 6'-8 3 4" CLEAR OPENING. 35" DOOR SWING. 2-ROW PIT, 24'-1"L 1'-0" CLEARANCE REQUIRED ABOVE BOOTH FOR EXPLOSION RELIEF SYSTEM. CONTROLLED AIRFLOW CEILING WITH (QTY 8) 6-TUBE LED, CLASS 1 DIVISION 2, INSIDE-ACCESSIBLE LIGHT FIXTURES.9'-0 1/2"WORKING HEIGHT11'-1 1/2"MAX. OVERALL HEIGHT(INLC. 1" LEVELING)L E G CONTROL PANEL4-SLAB PRODUCT DOOR WITH WINDOWS 10'-8"W X 8'-83 4"H CLEAR OPENING. ONE SLAB USED AS PERSONNEL EGRESS. 4-SLAB PRODUCT DOOR WITH WINDOWS 10'-8"W X 8'-83 4"H CLEAR OPENING. ONE SLAB USED AS PERSONNEL EGRESS. GUL2000 (GU-RC) AIR HEATER ANCHORS @ 12" O.C. AT OPENINGS THIS PAINT BOOTH IS ETL LISTED, REFERENCE ETL REPORT NUMBER 101579520CRT-001. IT HAS BEEN REVIEWED AND FOUND TO CONFORM TO THE REQUIREMENTS OF THE FOLLOWING STANDARDS BY INTERTEK TESTING LABORATORIES. - NFPA 33 STANDARD FOR SPRAY APPLICATION USING FLAMMABLE OR COMBUSTIBLE MATERIALS - NFPA 91 STANDARD FOR EXHAUST SYSTEMS FOR AIR CONVEYING OF VAPORS, GASES, MISTS AND NONCOMBUSTIBLE PARTICULATE SOLIDS, PAINT SPRAY BOOTHS AND DRYING OVENS - CSA C22.1 CANADIAN ELECTRICAL CODE PART 1: SAFETY STANDARD FOR ELECTRICAL INSTALLATOINS IN ADDITION TO THE ABOVE CONFORMANCES, THE PAINT BOOTH ALSO CONFORMS TO THE APPLICABLE REQUIREMENTS OF THE FOLLOWING CODES AND STANDARDS. - NFPA-70 NATIONAL ELECTRIC CODE - NFPA-86 STANDARD FOR OVENS AND FURNACES - NFPA-101 LIFE SAFETY CODE - OSHA SAFETY AND HEALTH STANDARDS (29CFR 110, 1910.107) - CURRENT EDITION INTERNATIONAL BUILDING CODE - CURRENT EDITION INTERNATIONAL FIRE CODE CHAPTER 24 PAINT BOOTH CONSTRUCTION NOTE: 1. GAS SUPPLY REQUIRED (BY OTHERS) TO GAS CONNECTION POINT (G). MINIMUM GAS PRESSURE IS REQUIRED AT MAXIMUM VOLUME CONSUMED. MINIMUM CIRCUIT CAPACITY IS REQUIRED (BY OTHERS) TO CONNECTION POINT (E). LIGHTING CIRCUIT IS REQUIRED (BY OTHERS) TO CONNECTION POINT (L). 2. PAINT BOOTH IS FABRICATED FROM 18/20 GAGE WHITE PRECOAT SHEET STEEL. 3. DUCTWORK IS FABRICATED FROM 18 GAGE G90 GALVANIZED STEEL. 4. GLASS USED IN THE PAINT BOOTH MEETS AND EXCEEDS ANSI Z-97.1 STANDARD. 5. FIRE SUPPRESSION SYSTEM IS NOT INCLUDED WITH THE STANDARD PAINT BOOTH BUT IS REQUIRED BY NFPA-33. 6. DUCT SUPPORT NOT SUPPLIED OR DESIGNED BY GFS. EQUIPMENT IS NOT DESIGNED TO SUPPORT DUCT. DUCT SUPPORTS SHALL BE DESIGNED TO RELIEVE THE EQUIPMENT OF ALL DUCT LOAD. 7. EXHAUST TERMINATION POINT. PER THE INTERNATIONAL FIRE CODE, THE TERMINATION POINT FOR EXHAUST DUCTS DISCHARGING TO THE ATMOSPHERE SHALL NOT BE THE LESS THAN THE FOLLOWING DISTANCES: 1. 30 FEET FROM THE LOT LINE; 2. 10 FEET FROM OPENINGS INTO THE BUILDING; 3. 6 FEET FROM EXTERIOR WALLS AND ROOFS; 4. 30 FEET FROM COMBUSTIBLE WALLS OR OPENINGS INTO THE BUILDING THAT ARE IN THE DIRECTION OF THE EXHAUST DISCHARGE; 5. 10 FEET ABOVE ADJOINING GRADE. 8. INCLUDED BUT NOT SHOWN: (1) BREATHABLE AIR SYSTEM AIR HEATER MAX AIR FLOW RATE (CFM) INTAKE / EXHAUST MOTOR (HP) FUEL MAX FIRING RATE (BTU/HR) MIN INLET PRESS. AT MAX FIRING RATE (INWC) MAX INLET PRESS. (PSI) TEMP. RISE (°F) INLET PIPE SIZE NPT (IN) 12541 10 / 10 NATURAL GAS 1440000 11.3 5.0 102 1 PROPANE 1125000 5.0 80 MOTOR MINIMUM CIRCUIT CAPACITY MOTOR SPECIFICATIONS FULL LOAD AMP DRAW /MINIMUM CIRCUIT CAPACITY 10HP INTAKE, 10HP EXHAUST 230V 1PH 208V 3PH 230V 3PH 480V 3PH 575V 3PH INTEGRATED ADVANCE CURE (4) 1HP ADVANCE CURE MOTORS 83.0 / 104.0 LIGHTING CIRCUIT QUANTITY OF LIGHT FIXTURES (4-TUBE, 6-TUBE, STD OR LED) SINGLE PHASE MINIMUM CIRCUIT CAPACITY (AMPS) 120V 277V 14 30 20 ∅34" STACK WEIGHTS DUCT FAN MOTOR RINGS SILENCER NO-LOSS ARV LBS/LF LBS/PAIR OF RINGS LBS HOOD LBS LBS LBS LBS LBS 105 115 21.97 198 150 45 A B C D E 1234GLOBAL FINISHING SOLUTIONS12731 NORWAY ROADOSSEO, WI 54758 USA800-848-8738 globalfinishing.comIMPORTANT NOTE: This print and all information contained therein is the sole property of GlobalFinishing Solutions, LLC ("GFS"). It is not to be used or reproduced in any manner or submitted toother parties for examination without the express written approval of GFS pursuant to a fully-executedcontract or purchase order for GFS-manufactured equipment. Customer may make and retain copies ofthe print for information and reference in connection with an equipment order; however, this print isnot intended or represented to be suitable for re-use by Customer or others on extensions of the orderor on any other project. Any use without written verification is at Customer's sole risk and withoutliability to GFS, its affiliates, or agents.© Global Finishing Solutions, LLCDRAWING DRAWING SET REVISION ORDER/SERIAL NUMBERSCALEDRAWN BYDATEREVIEW BYREVIEW DATEMODEL INFOSOLD TOSHIP TOCARMAX12800 TUCKAHOE CREEK PARKWAYRICHMOND, VA 232381115CARMAX 7144 INDIANAPOLIS9750 NORTH GRAY RDINDIANAPOLIS, IN 46280U143126 SD A A-GAULTRA XD DOWNDRAFT BOOTH27'L x 14'W x 9'H, w/ ULTRA AIR HEATER1/4"=1'-0"AJE6/24/2022DAT6/24/20222022REVISION HISTORY REV DATE REFERENCE BY DESCRIPTION 06/30/202210/25/22