SD B GA ULTRA XD PAINT MIX ROOM
PERSONNEL DOOR 2'-8" X 6'-8 3/4" CLEAR OPENING. 35" DOOR SWING. ANY DEVICE LOCATED WITHIN 3' OF DOOR OPENING MUST BE LISTED FOR CLASS 1, DIVISION 2. WIRING INSTALLATION TO THE DEVICE MUST MEET THE REQUIREMENTS FOR A CLASS 1, DIVISION 2 LOCATION.12'-0"WORKING LENGTH6'-0" WORKING WIDTH 12'-5"OVERALL LENGTH6'-2 1/2" OVERALL WIDTH PLAN VIEW LH SIDE ELEVATION REAR ELEVATION RH SIDE ELEVATION LIGHT LIGHTE Ø10" EXHAUST EXHAUST MOTOR TWO POSITION TOGGLE SWITCH. MUST BE LOCATED A MINIMUM OF 3 FEET AWAY FROM THE PERSONNEL DOOR OPENING.4" SPILLCONTAINMENTFRONT ELEVATION 19' BLDG ROOF HEIGHT (REF)9'-0 1/2"WORKING HEIGHT12'-0"OVERALL HEIGHT4-TUBE LED, CLASS 1 DIVISION 2, INSIDE-ACCESSIBLE LIGHT FIXTURES. THIS PAINT MIX ROOM IS ETL LISTED, REFERENCE ETL REPORT NUMBER 100690377CRT-001. IT HAS BEEN REVIEWED AND FOUND TO CONFORM TO THE REQUIREMENTS OF THE FOLLOWING STANDARDS BY INTERTEK TESTING LABORATORIES. - NFPA 33 STANDARD FOR SPRAY APPLICATION USING FLAMMABLE OR COMBUSTIBLE MATERIALS - NFPA 91 STANDARD FOR EXHAUST SYSTEMS FOR AIR CONVEYING OF VAPORS, GASES, MISTS AND NONCOMBUSTIBLE PARTICULATE SOLIDS, PAINT SPRAY BOOTHS AND DRYING OVENS IN ADDITION TO THE ABOVE CONFORMANCES, THE MIX ROOM ALSO CONFORMS TO THE APPLICABLE REQUIREMENTS OF THE FOLLOWING CODES AND STANDARDS. - NFPA-70 NATIONAL ELECTRIC CODE - OSHA SAFETY AND HEALTH STANDARDS (29CFR 110, 1910.107) - CURRENT EDITION INTERNATIONAL BUILDING CODE - CURRENT EDITION INTERNATIONAL FIRE CODE CHAPTER 24 PAINT MIX ROOM CONSTRUCTION NOTE: 1. MAXIMUM PAINT STORAGE IN THE PAINT MIX ROOM IS 60 GALLONS. 2. MINIMUM CIRCUIT CAPACITY IS REQUIRED (BY OTHERS) TO CONNECTION POINT (E). 3. MIX ROOM IS FABRICATED FROM 18/20 GAGE WHITE PRECOAT SHEET STEEL. 4. DUCTWORK IS FABRICATED FROM 18 GAGE G90 GALVANIZED STEEL. 5. GLASS USED IN THE PAINT MIX ROOM MEETS AND EXCEEDS ANSI Z-97.1 STANDARD. 6. FIRE SUPPRESSION SYSTEM IS NOT INCLUDED WITH THE STANDARD MIX ROOM BUT IS REQUIRED BY NFPA-33. 7. PAINT MIX ROOM EXHAUST FAN AIRFLOW RATE IS 949 CFM @ 1/2" OF STATIC PRESSURE (1,740 FPM) AND MUST BE OPERATIONAL AT ALL TIMES WHEN PAINT IS BEING STORED. 8.DUCT SUPPORT NOT SUPPLIED OR DESIGNED BY GFS. EQUIPMENT IS NOT DESIGNED TO SUPPORT DUCT. DUCT SUPPORTS SHALL BE DESIGNED TO RELIEVE THE EQUIPMENT OF ALL DUCT LOAD. 9.EXHAUST TERMINATION POINT. PER THE INTERNATIONAL FIRE CODE, THE TERMINATION POINT FOR EXHAUST DUCTS DISCHARGING TO THE ATMOSPHERE SHALL NOT BE LESS THAN THE FOLLOWING DISTANCES: 1.30 FEET FROM THE LOT LINE; 2.10 FEET FROM OPENINGS INTO THE BUILDING; 3.6 FEET FROM EXTERIOR WALLS AND ROOFS; 4.30 FEET FROM COMBUSTIBLE WALLS OR OPENINGS INTO THE BUILDING THAT ARE IN THE DIRECTION OF THE EXHAUST DISCHARGE; 5.10 FEET ABOVE ADJOINING GRADE. 6.25 FEET FROM ANY UNPROTECTED OPENING IN AN NONCOMBUSTIBLE OR LIMITED COMBUSTIBLE CONSTRUCTION THAT ARE IN THE DIRECTION OF THE EXHAUST DISCHARGE. 7.25 FEET FROM ANY EXIT DISCHARGE OR PUBLIC WAY THAT ARE IN THE DIRECTION OF THE EXHAUST DISCHARGE. 10.INCLUDED BUT NOT SHOWN: (1)Ø10" ROOF FLANGE (1)MIX ROOM AIR DEFLECTOR ∅10" STACK WEIGHTS DUCT FAN MOTOR RINGS SILENCER NO-LOSS ARV LBS/LF LBS/PAIR OF RINGS LBS HOOD LBS LBS LBS LBS LBS 24 6.47 45 27 A B C D E 1234GLOBAL FINISHING SOLUTIONS12731 NORWAY ROADOSSEO, WI 54758 USA800-848-8738globalfinishing.comIMPORTANT NOTE: This print and all information contained therein is the sole property of GlobalFinishing Solutions, LLC ("GFS"). It is not to be used or reproduced in any manner or submitted toother parties for examination without the express written approval of GFS pursuant to a fully-executedcontract or purchase order for GFS-manufactured equipment. Customer may make and retain copies ofthe print for information and reference in connection with an equipment order; however, this print isnot intended or represented to be suitable for re-use by Customer or others on extensions of the orderor on any other project. Any use without written verification is at Customer's sole risk and withoutliability to GFS, its affiliates, or agents.© Global Finishing Solutions, LLCDRAWING DRAWING SET REVISION ORDER/SERIAL NUMBERSCALEDRAWN BYDATEREVIEW BYREVIEW DATEMODEL INFOSOLD TOSHIP TOCARMAX12800 TUCKAHOE CREEK PARKWAYRICHMOND, VA 232381115CARMAX 7144 INDIANAPOLIS9750 NORTH GRAY RDINDIANAPOLIS, IN 46280U143126 SD A B-GAULTRA XD PAINT MIX ROOM12'L x 6'W x 9'H, 3-SIDED3/8" = 1'-0"AJE6/24/2022DAT6/24/20222022REVISION HISTORY REV DATE REFERENCE BY DESCRIPTION ELECTRICAL REQUIREMENTS ELECTRICAL DEVICE MOTOR FULL LOAD AMP DRAW MINIMUM CIRCUIT CAPACITY EXHAUST FAN & INTAKE FAN FAN MOTOR (EACH)1/2HP, 120V, 1PH 9.8 30 AMP LIGHT FIXTURES 120V / 277V 1.0 / 0.5 (EACH)06/30/202210/25/22