Loading...
HomeMy WebLinkAboutS100 1st Floor Structural Ceiling Plan01. EXISTING FRAMING - VERIFY SPACING 02. EXISTING BEAM. 03. EXISTING HEADER. 04. NEW 2X6 JOISTS @ 16" O.C. - FINAL DESIGN / SIZING / SPACING BY STRUCTURAL ENGINEER. FRAMING PLAN NOTES X A. FIELD VERIFY ALL CONDITIONS. B. REFER TO ARCHITECT IF THERE ARE ANY DISCREPANCIES TO PLANS AND ACTUAL FIELD CONDITIONS. C. ASSUME ALL VAULTED CEILINGS ARE BUILT DOWN W/2x FRAMING TO ACCOMMODATE INSULATION + VENTILATION DEPTH - REF: DETAILS. D. 2 ADJACENT LINES ON FRAMING PLAN MEANS DOUBLED-UP JOIST. REF: SPECIFICATION AND STRUCTURAL ENGINEER. E. BEAMS AS SPECIFIED MAY ONLY BE SUBSTITUTED WITH ARCHITECT'S PRIOR APPROVAL (LVL VS. GLULAM). IN SOME CASES THE BEAMS MAY BE EXPOSED, WHICH IS WHY IT MATTERS. F. PER SPECIFICATIONS, ALL EXTERIOR STRUCTURAL LUMBER IS TO BE TREATED. G. ALL STRUCTURAL CONDITIONS TO BE REVIEWED BY STRUCTURAL ENGINEER. ANY MODIFICATIONS TO ARCHITECT'S DESIGN INTENT MUST BE APPROVED BY ARCHITECT. H. FRAMING PLANS ARE INDICATED TO SHOW DESIGN INTENT & SPECIAL CONDITIONS ONLY - NOT EVERY DETAIL OF STANDARD SYSTEM. FRAMING GENERAL NOTES 03 A300 01 A300 02 A300 04 A300 02 01 01 01 01 01 0404 0101 01 01 01 01 02 02 03 03 03 03 0303 03 03 03 03 02 HEADER - (2) 2X8 HEADER - (2) 2X10HEADER -(2) 2X10HEADER - (2) 2X10 HEADER - (2) 2X10 HEADER - (2) 2X10 HEADER - (2) 2X10 HEADER -(2) 2X10HEADER - (2) 2x10 HEADER -(2) 2X10HEADER - (2) 2x10 HEADER -(2) 2X10SLOPEDSLOPEDSLOPEDREF: SECTION SLOPEDHEADER -(2) 2X10HEADER - (2) 2x10 - BLACK COLUMN - BUILT-UP STUD COLUMN SUPPORTING LOADS FROM ABOVE - GRAY COLUMN - BUILT-UP STUD COLUMN BELOW - WHITE COLUMN - EXISTING COLUMN - DIAGONAL DOWN HATCH - LOAD-BEARING WALL BELOW FRAMING PLAN SYMBOLS - SCREENED DIAGONAL DOWN HATCH - LOAD-BEARING WALL FROM ABOVE - THIN LINE - 2x JOISTS/RAFTERS AT SPACING SPECIFIED IN PLAN NOTE DESCRIPTION. CD1 DOCUMENTS: THESE DOCUMENTS ARE BASIC CONSTRUCTION DOCUMENTS FOR USE IN COMPLETING SCOPE PRICING. ONCE WE CONFIRM SCOPE PRICING, WE WILL COMPLETE "CD2" DOCUMENTS FOR CONSTRUCTION AND PERMITTING. SHEET NUMBER: SHEET TITLE: PROJECT NAME: CONSULTANT:Copyright HAUS Architecture LLC, 2022; Scope Documents Per Sheet A000 DRAWN BY: CHECKED BY: PROJECT NUMBER: FILE NAME: COPYRIGHT:HAUS - 2022 MARK: DATE: DESCRIPTION:317.652.2828HAUS-ARCH.COMcreate@haus-arch.com841 E 64th Street #201Indianapolis, IN 46220STATUS 10000 Upton Court,Carmel, IN 4608010.21.22 CD1 EGR/HEM CAS 2022_27 A104PRIVATERESIDENCECeilingFramingPlanNOT FOR CONSTRUCTION 1/4" = 1'-0"01 Ceiling Framing Plan 12/27/22