HomeMy WebLinkAboutS100 1st Floor Structural Ceiling Plan01. EXISTING FRAMING - VERIFY SPACING
02. EXISTING BEAM.
03. EXISTING HEADER.
04. NEW 2X6 JOISTS @ 16" O.C. - FINAL DESIGN / SIZING / SPACING BY
STRUCTURAL ENGINEER.
FRAMING PLAN NOTES X
A. FIELD VERIFY ALL CONDITIONS.
B. REFER TO ARCHITECT IF THERE ARE ANY DISCREPANCIES TO PLANS AND
ACTUAL FIELD CONDITIONS.
C. ASSUME ALL VAULTED CEILINGS ARE BUILT DOWN W/2x FRAMING TO
ACCOMMODATE INSULATION + VENTILATION DEPTH - REF: DETAILS.
D. 2 ADJACENT LINES ON FRAMING PLAN MEANS DOUBLED-UP JOIST. REF:
SPECIFICATION AND STRUCTURAL ENGINEER.
E. BEAMS AS SPECIFIED MAY ONLY BE SUBSTITUTED WITH ARCHITECT'S PRIOR
APPROVAL (LVL VS. GLULAM). IN SOME CASES THE BEAMS MAY BE
EXPOSED, WHICH IS WHY IT MATTERS.
F. PER SPECIFICATIONS, ALL EXTERIOR STRUCTURAL LUMBER IS TO BE TREATED.
G. ALL STRUCTURAL CONDITIONS TO BE REVIEWED BY STRUCTURAL ENGINEER.
ANY MODIFICATIONS TO ARCHITECT'S DESIGN INTENT MUST BE APPROVED
BY ARCHITECT.
H. FRAMING PLANS ARE INDICATED TO SHOW DESIGN INTENT & SPECIAL
CONDITIONS ONLY - NOT EVERY DETAIL OF STANDARD SYSTEM.
FRAMING GENERAL NOTES
03
A300
01
A300
02
A300
04
A300
02
01
01
01
01
01
0404
0101
01
01
01
01
02
02
03
03
03
03
0303
03
03
03
03
02
HEADER - (2) 2X8
HEADER - (2) 2X10HEADER -(2) 2X10HEADER - (2) 2X10 HEADER - (2) 2X10
HEADER - (2) 2X10
HEADER - (2) 2X10
HEADER -(2) 2X10HEADER - (2) 2x10 HEADER -(2) 2X10HEADER - (2) 2x10 HEADER -(2) 2X10SLOPEDSLOPEDSLOPEDREF: SECTION
SLOPEDHEADER -(2) 2X10HEADER - (2) 2x10
- BLACK COLUMN - BUILT-UP STUD COLUMN SUPPORTING LOADS FROM ABOVE
- GRAY COLUMN - BUILT-UP STUD COLUMN BELOW
- WHITE COLUMN - EXISTING COLUMN
- DIAGONAL DOWN HATCH - LOAD-BEARING WALL BELOW
FRAMING PLAN SYMBOLS
- SCREENED DIAGONAL DOWN HATCH - LOAD-BEARING WALL FROM ABOVE
- THIN LINE - 2x JOISTS/RAFTERS AT SPACING SPECIFIED IN PLAN NOTE DESCRIPTION.
CD1 DOCUMENTS:
THESE DOCUMENTS ARE BASIC CONSTRUCTION
DOCUMENTS FOR USE IN COMPLETING SCOPE
PRICING. ONCE WE CONFIRM SCOPE PRICING,
WE WILL COMPLETE "CD2" DOCUMENTS FOR
CONSTRUCTION AND PERMITTING.
SHEET NUMBER:
SHEET TITLE:
PROJECT NAME:
CONSULTANT:Copyright HAUS Architecture LLC, 2022; Scope Documents Per Sheet A000 DRAWN BY:
CHECKED BY:
PROJECT NUMBER:
FILE NAME:
COPYRIGHT:HAUS - 2022
MARK: DATE: DESCRIPTION:317.652.2828HAUS-ARCH.COMcreate@haus-arch.com841 E 64th Street #201Indianapolis, IN 46220STATUS
10000 Upton Court,Carmel, IN 4608010.21.22 CD1
EGR/HEM
CAS
2022_27
A104PRIVATERESIDENCECeilingFramingPlanNOT FOR
CONSTRUCTION
1/4" = 1'-0"01 Ceiling Framing Plan
12/27/22