Loading...
HomeMy WebLinkAboutC100 - Cover pageACCENT WALL FINISH LOCATION: FLOORING TRANSITION: ROOM FINISH TAG: FLOOR FINISH BASE FINISH WALL FINISH CEILING FINISH WALL FINISH X FLOOR FINISH X FLOOR FINISH X FINISH REMARKS WD1 - B1 - P1 - C1 - XXXACCENT FINISHES: ELEVATION CERAMIC TILE MASONRY CONCRETE WOOD BRICK GLAZING SECTION GYPSUM BD./ STUCCO STEEL ALUMINUM RIGID INSULATION EARTH NON-CONTINUOUS WOOD BLOCKING CONTINUOUS WOOD BLOCKING BATT INSULATION BRICK 2X4 FLUOURESCENT FIXTURE DIRECT/INDIRECT FLUOURESCENT FIXTURE SURFACE MOUNTED PARABOLIC LINEAR UPLIGHTING (PENDANT-MOUNT) RECESSED PENDANT DIRECTIONAL DOWNLIGHT/WALL WASH WALL-MOUNTED FIXTURE PENDANT LIGHT FIXTURE DIRECTIONAL DOWNLIGHT/WALL WASH EMERGENCY LIGHTING- WALL MOUNT EMERGENCY LIGHTING-CEILING MOUNT SPEAKER EXIT SIGN (CEILING MOUNT) EXIT SIGN (WALL MOUNT) HVAC SUPPLY GRILLE HVAC RETURN GRILLE/EXHAUST GYPSUM BOARD CEILING EXHAUST FAN (CEILING) FULL - HEIGHT MILLWORK ABUTTING CEILING SMOKE ALARM/CARBON MONOXIDE DETECTOR S S/C NEW WALL NEW DOOR EXISTING WALL EXISTING DOOR DEMO WALL DEMO DOOR A. ALL INTERIOR WALLS TO BE TYPE 3a UNLESS NOTED OTHERWISE. B. ALL EXTERIOR WALLS TO BE TYPE 2a UNLESS NOTED OTHERWISE. C. ALL WALLS TO EXTEND TO UNDERSIDE OF STRUCTURE ABOVE UNLESS NOTED OTHERWISE. D. PROVIDE SOUND INSULATION IN WALLS SURROUNDING THE FOLLOWING: BATHS / BEDROOMS / MECHANICAL ROOMS. TYPE w.1 (EXISTING BRICK EXTERIOR) (INT.) 1/2" GYPSUM DRYWALL, 2X4 STUD WALL @ 16" O.C. W/ FULL CAVITY INSULATION (R-13), 1/2" SHEATHING (OSB/PLYWOOD), WEATHER BARRIER, AIR SPACE, BRICK (EXT.). TYPE w.2a (EXISTING EXTERIOR SIDING - VINYL) (INT.) 1/2" GYPSUM DRYWALL, 2X4 STUD WALL @ 16" O.C. W/ FULL CAVITY INSULATION (R-13), 1/2" SHEATHING (OSB/PLYWOOD), WEATHER BARRIER, SIDING (EXT.). TYPE w.3a 3 1/2" WOOD STUD @ 16" O.C., W/ 1/2" GYPSUM DRYWALL EACH FACE. STUDS TO EXTEND TO UNDERSIDE OF STRUCTURE - UNLESS NOTED OTHERWISE. GYPSUM DRYWALL TO EXTEND TO UNDERSIDE OF STRUCTURE (TYPICAL). TYPE w.3b 5 1/2" WOOD STUD @ 16" O.C., W/ 1/2" GYPSUM DRYWALL EACH FACE. STUDS TO EXTEND TO UNDERSIDE OF STRUCTURE - UNLESS NOTED OTHERWISE. GYPSUM DRYWALL TO EXTEND TO UNDERSIDE OF STRUCTURE (TYPICAL). INSULATE ALL BATHROOM WALLS. TYPE w.3c 3 1/2" WOOD STUD @ 16" O.C. (FILL WITH INSULATION), W/ 5/8" GYPSUM DRYWALL EACH FACE. STUDS TO EXTEND TO UNDERSIDE OF STRUCTURE - UNLESS NOTED OTHERWISE. GYPSUM DRYWALL TO EXTEND TO UNDERSIDE OF STRUCTURE (TYP.). TYPE w.2b (NEW SIDING EXTERIOR - EIFS) (INT.) 1/2" GYPSUM DRYWALL, 2X4 STUD WALL @ 16" O.C. W/ FULL CAVITY INSULATION (R-19), 1/2" SHEATHING (OSB/PLYWOOD), 1 1/2" INSULATION BOARD + 3/8" EIFS (EXT.). TYPE w.3d 5 1/2" WOOD STUD @ 16" O.C., W/ 1/2" GYPSUM DRYWALL EACH FACE. STUDS TO EXTEND TO UNDERSIDE OF STRUCTURE - UNLESS NOTED OTHERWISE. GYPSUM DRYWALL TO EXTEND TO UNDERSIDE OF STRUCTURE (TYPICAL). INSULATE ALL BATHROOM WALLS. TYPE w.3e 3 1/2" WOOD STUDS @ 16" O.CO. EITHER SIDE WITH 2" AIR GAP BETWEEN ADN 1/2" GYPSUM DRYWALL EACH FACE. STUDS TO EXTEND TO UNDERSIDE OF STRUCTURE - UNLESS NOTED OTHERWISE. GYPSUM DRYWALL TO EXTEND TO UNDERSIDE OF STRUCTURE(TYP.). WALL TYPES LOCATION MAP SCALE: N.T.S.MERIDIAN ST / US‐31NI‐70E WASHINGTON ST I ‐65SMICH IG AN RD INDIANAPOLIS SITE I‐6 5 N I‐74 W I‐70 WUS‐40 US‐36 MARION HANCOCK MADISON HAMILTONBOONE HENDRICKS I‐69N I‐74 JOHNSON I‐65S V A J T CD1 DOCUMENTS: THESE DOCUMENTS ARE BASIC CONSTRUCTION DOCUMENTS FOR USE IN COMPLETING SCOPE PRICING. ONCE WE CONFIRM SCOPE PRICING, WE WILL COMPLETE "CD2" DOCUMENTS FOR CONSTRUCTION AND PERMITTING. GB ROOM IDENTIFICATION SECTION CUT INDICATION DETAIL IDENTIFICATION ELEVATION SYMBOL REVISION SYMBOL SPECIFIC NOTES WINDOWS/GLAZING IDENTIFICATION DOOR IDENTIFICATION FURNITURE AND EQUIPMENT IDENTIFICATION TOILET ACCESSORIES GENERAL NOTES WALL TYPE ELEVATION ANNOTATION NORTH ARROW 1 NOTE 100 x FIRST LEVEL ELEV. 100'-0" 1 AXXX 100 ROOM NAME 1 1 w.1 1 1 AXXX 1 AXXX ABOVE FINISH FLOOR AIR CONDITIONER ALTERNATE ALUMINUM BELOW FINISH FLOOR BUILDING CABINET CARPET CEILING CERAMIC TILE CLOSET COLUMN CONCRETE MASONRY UNIT CONTINUOUS DEMOLITION DETAIL DIAMETER DOWN DOWNSPOUT DRAWING ELEVATOR EQUIPMENT EXISTING EXTERIOR FEET FINISH FIRE EXTINGUISHER FLOOR DRAIN FOOTING GLASS, GLAZING GYPSUM HEIGHT HOLLOW CORE HOLLOW METAL INSULATION INTERIOR JUNCTION BOX LAMINATE LAVATORY MAXIMUM MANUFACTURER CL AFF A/C ALT ALUM BFF BLDG CAB CPT CLG CT CLO COL CMU CONT DEMO DTL DIA DN DS DWG ELEV EQUIP EXIST EXT FT FIN FE FD FTG GL GYP HT HC HM INSUL INT JB LAM LAV MAX MFR METAL MECHANICAL MINIMUM MIRROR MICROWAVE NOT TO SCALE NUMBER ON CENTER OWNER FURNISHED/OWNER INSTALLED OWNER FURNISHED/ CONTRACTOR INSTALLED CONTRACTOR FURNISHED/ CONTRACTOR INSTALLED PAINT PLUMBING PROJECT REFRIGERATOR REINFORCEMENT REQUIRED REVISION ROUGH OPENING SIMILAR SOAP DISPENSER SQUARE FEET STANDARD STAINLESS STEEL STEEL STORAGE TO BE DETERMINED TYPICAL UNLESS NOTED OTHERWISE URINAL VINYL COMPOSITION TILE VERIFY IN FIELD WATER CLOSET WITHOUT WOOD MTL MECH MIN MIR MW NTS NO. O.C. OFOI OFCI CFCI PT PLBG PROJ REF REINF REQ REV RO SIM SD SF STD SS STL STOR TBD TYP UNO UR VCT VIF WC W/O WD CENTERLINE Copyright HAUS Architecture LLC, 2022; Scope Documents Per Sheet A000GENERAL NOTES (RESIDENTIAL) N LIGHT SWITCH THREE-WAY LIGHT SWITCH LIGHT SWITCH, DIMMER LIGHT SWITCH, JAMB DUPLEX RECEPTACLE, 120V, +18" A.F.F. (U.N.O.) QUAD RECEPTACLE, 120V, +18" A.F.F. (U.N.O.) TELEPHONE JACK, +18" A.F.F. (U.N.O.) DATA JACK, +18" A.F.F. (U.N.O.) DUPLEX DATA/TELEPHONE JACK, +18" A.F.F. (U.N.O.) JUNCTION BOX, +18" A.F.F. (U.N.O.) INTERCOM SYSTEM ALARM CONTROL PANEL THERMOSTAT INDICATED NEW ITEM DOOR BELL SPEAKER VOLUME CONTROL GLASS BREAK SENSOR ELECTRICAL LEGEND A. CONFORM ALL CONSTRUCTION TO THE BUILDING CODES INDICATED (OR MOST CURRENT) UNDER CODES AND STANDARDS AS WELL AS LOCAL, COUNTY, AND/OR CITY JURISDICTIONS. IF SUCH RULES AND REGULATIONS ARE IN CONFLICT WITH ANY PORTION OF THESE DOCUMENTS, INFORM THE ARCHITECT BEFORE PROCEEDING. B. THESE GENERAL CONSTRUCTION NOTES WORK IN COMPLIMENT TO THE DRAWINGS. WHERE DRAWINGS AND CONSTRUCTION NOTES ARE IN CONFLICT, PLEASE NOTIFY THE ARCHITECT TO REQUEST CLARIFICATION. WHERE DRAWINGS ARE IN CONFLICT WITH THEMSELVES (INCLUDES ALL DRAWINGS, INCLUDING CONSULTANT DRAWINGS), PLEASE NOTIFY THE ARCHITECT TO REQUEST CLARIFICATION. IN THESE CONDITIONS, THE MOST RESTRICTIVE OR MOST EXPENSIVE CONDITION PREVAILS. ARCHITECT WILL MAKE THE FINAL DETERMINATION WHICH CONDITION TO INSTALL IN FIELD. THE ARCHITECT’S DECISIONS ON MATTERS RELATING TO AESTHETIC EFFECT WILL BE FINAL IF CONSISTENT WITH THE INTENT EXPRESSED IN THE CONTRACT DOCUMENTS (INCLUDES DRAWINGS). C. PARTIAL SETS OF DRAWINGS ARE INCOMPLETE AND SHALL NOT BE DISTRIBUTED NOR UTILIZED BY THE CONTRACTOR. IT IS THE CONSTRUCTION MANAGER’S (OWNER’S / BUILDER’S / ETC.) RESPONSIBILITY TO REVIEW AND COORDINATE THE WORK OF ALL CONTRACTORS, TRADES, AND SUPPLIERS WITH THE REQUIREMENTS OF THE CONTRACT BEFORE COMMENCING ANY WORK AND TO ASSURE THAT ALL PARTIES ARE AWARE OF ALL REQUIREMENTS, REGARDLESS OF WHERE THE REQUIREMENTS OCCUR IN THE CONTRACT DOCUMENTS. D. ANY AND ALL PENETRATIONS SHALL RECEIVE SEALANT AND APPROPRIATE FLASHINGS TO SEAL ANY TYPE OF ENERGY LOSS OR WATER INTRUSION. FIRESTOPPING SHALL BE APPLIED IN THE OPENINGS AROUND PENETRATIONS THROUGH FIRE-RATED ASSEMBLIES AND THROUGH EACH FLOOR. E. VERIFY ALL EXISTING CONDITIONS PRIOR TO THE START OF CONSTRUCTION. NOTIFY THE ARCHITECT IMMEDIATELY OF ANY CONFLICTS PRIOR TO PROCEEDING WITH WORK. F. DIMENSIONS ARE INDICATED FROM FACE OF COLUMN, FACE OF RAILING, FACE OF MASONRY, FACE OF STUD, AND EXISTING WALL FINISH UNLESS OTHERWISE INDICATED. FIELD VERIFY EXISTING CONDITIONS. EXTERIOR DIMENIONS OF WALLS ARE FROM FACE OF SHEATHING. G. THE CONTRACTOR IS TO VERIFY AND COORDINATE ALL APPLICABLE DIMENSIONS OF FIXTURES AND EQUIPMENT SUPPLIED AND/OR INSTALLED BY OTHERS. CONTRACTOR IS TO PROVIDE ALL BLOCKING AS NECESSARY TO ATTACH OWNER EQUIPMENT (WHETHER OR NOT EQUIPMENT IS FURNISHED BY CONTRACTOR.) H. THE POSTING OF AN OFFICIAL BUILDING PERMIT ON THE JOB SITE IS REQUIRED. CONTRACTOR IS RESPONSIBLE FOR SECURING ALL PERMITS. I. THE USE OF THE WORDS "PROVIDE" OR "PROVIDED" IN CONNECTION WITH ANY ITEM SPECIFIED, IS INTENDED TO MEAN, UNLESS OTHERWISE NOTED, THAT SUCH BE FURNISHED AND INSTALLED, AND CONNECTED WHERE SO REQUIRED. J. UPON COMPLETION OF PROJECT, OBTAIN ALL FINAL INSPECTIONS AS REQUIRED BY LOCAL JURISDICTIONS AND FURNISH OWNER WITH EVIDENCE OF ALL SUCH INSPECTIONS AND CERTIFICATES OF OCCUPANCY. K. UPON COMPLETION OF PROJECT, PROVIDE OWNER WITH ALL INSTRUCTION MANUALS, WARRANTIES OR OTHER DOCUMENTS REQUIRED FOR THE OPERATION OR MAINTENANCE OF ANY ITEM IN THE CONTRACTOR'S WORK. L. THESE CONSTRUCTION NOTES AND/OR DRAWINGS ARE SUPPLIED TO ILLUSTRATE THE DESIGN AND GENERAL TYPE OF CONSTRUCTION DESIRED AND ARE INTENDED TO IMPLY THE FINEST QUALITY OF CONSTRUCTION, MATERIAL AND WORKMANSHIP THROUGHOUT. M. THE CONTRACTOR SHALL MAINTAIN A CURRENT AND COMPLETE SET OF CONSTRUCTION DOCUMENTS ON THE SITE DURING ALL PHASES OF CONSTRUCTION FOR USE OF ALL TRADES. N. ALL MEANS OF EGRESS SHALL BE MAINTAINED AT ALL TIMES. O. THE CONTRACTOR SHALL PROTECT ALL EXISTING AND NEW MATERIALS AND FINISHES FROM DAMAGE WHICH MAY OCCUR FROM CONSTRUCTION, DEMOLITION, PAINT, DUST, WATER, ETC. ALL SUCH DAMAGE SHALL BE REPAIRED OR REPLACED TO THE SATISFACTION OF THE ARCHITECT AND OWNER AT THE CONTRACTOR'S EXPENSE. P. SCOPE DRAWINGS: THESE DRAWINGS INDICATE THE GENERAL SCOPE OF THE PROJECT IN TERMS OF ARCHITECTURAL DESIGN CONCEPT, THE DIMENSIONS OF THE BUILDING, THE MAJOR ARCHITECTURAL ELEMENTS AND VERY GENERAL TYPE OF STRUCTURAL, MECHANICAL AND ELECTRICAL SYSTEMS. THE DRAWINGS DO NOT NECESSARILY INDICATE OR DESCRIBE ALL WORK REQUIRED FOR FULL PERFORMANCE AND COMPLETION OF THE REQUIREMENTS OF THE CONTRACT. ON THE BASIS OF THE GENERAL SCOPE INDICATED OR DESCRIBED, THE TRADE CONTRACTORS SHALL FURNISH ALL ITEMS REQUIRED FOR THE PROPER EXECUTION AND COMPLETION OF THE WORK. Q. OWNERSHIP: THE DRAWINGS HAVE BEEN PREPARED SOLELY FOR USE ON THE SPECIFIC PROPERTY REFERENCED AND MAY NOT BE ALTERED OR USED FOR ANY OTHER INTEREST OR PROJECT WITHOUT ARCHITECT PERMISSION. ARCHITECT OWNS THE COPYRIGHT. OWNER RIGHTS ARE AS OUTLINED IN THE OWNER/ARCHITECT AGREEMENT. R. ALL CONTRACTORS SHALL FIELD VERIFY ALL CONDITIONS TO ENSURE PROPER REQUIRED CLEARANCES, FUNCTIONALITY, AND FULL OPERABILITY OF THEIRS AND COORDINATING SCOPES OF WORK. ARCHITECTS DRAWINGS ARE NOT SHOP DRAWINGS. SYMBOLS LEGENDSYMBOLS LEGEND STANDARD ABBREVIATIONS:REFLECTED CEILING LEGEND: MATERIALS LEGEND: FINISH PLAN SYMBOLS GENERAL INFORMATION DRAWING LIST WALL TYPES ANNOTATION LEGEND GENERAL NOTES (RESIDENTIAL) CODES & STANDARDS APPLICABLE BUILDING CODES (RESIDENTIAL) · 2020 INDIANA RESIDENTIAL CODE · 2018 INTERNATIONAL RESIDENTIAL CODE, FIRST PRINTING AUG. 2017, INCORPORATED BY REFERENCE W/ INDIANA AMENDMENTS CLIMATE ZONE: BUILDING THERMAL ENVELOPE: · CONFIRM WITH BUILDING OFFICIAL THE ACCEPTED OR REQUIRED PROCEDURES FOR VISUAL OR TESTING TO CONFIRM AIR TIGHTNESS AT END OF ROUGH-IN AND INSULATION PHASES. · TOTAL UA ALTERNATIVE USED TO COMPLY. STATUS SHEET NUMBER: SHEET TITLE: PROJECT NAME: DRAWN BY: CHECKED BY: PROJECT NUMBER: FILE NAME: COPYRIGHT:HAUS - 2022 MARK: DATE: DESCRIPTION:317.652.2828HAUS-ARCH.COMcreate@haus-arch.com841 E 64th Street #201Indianapolis, IN 46220STRUCTURAL ENGINEER: J D 3 MARION COUNTY: INDIANA 5 A000PRIVATERESIDENCE10000 Upton Court,Carmel, IN 4608010.21.22 CD1 NOT FOR CONSTRUCTION Cover SheetEGR/HEM CAS 2022_27 Drawing List Sheet Number Sheet Name A000 Cover Sheet A001 Architectural Specifications A002 Architectural Specifications A100 Site Plan ‐ Demo + New A101 Demo Plan A102 Demo Elevations A103 Foundation Plan + Slab Plan A104 Ceiling Framing Plan A105 First Floor Plan A106 Finish Plan A107 Reflected Ceiling Plans A200 Exterior Elevations A300 Sections A501 Door / Window Details A600 Opening Schedule A700 Lighting Plan & Schedule A900 3D Views ‐  Exterior A901 3D Views ‐ Interior 12/27/22