Loading...
HomeMy WebLinkAbout05080291 Correspondence ," O:;()oOZ91 Cc Ochs, James A lJ t U P tL D l. LM"" r J ~/I(~S /010 From: Sent: To: Cc: Subject: Frank Parisi [FParisi@williams-architects.com] Thursday, February 09,200612:16 PM Ochs, James A; Kent Forman dbowden@summitconst.com; Steve W. Mihelich; Blanchard, Jim E RE: Bather Loads at Monon Recreation Center - Permit No 05080291 Mr. Gchs: We have revisited our review of the Indoor pools and decks for Carmel- Monon Recreation Center. As requested, we are providing the following information. 1. Total number of occupants for the indoor pools = 536 bathers. 2. Total number of occupants for the indoor pool deck areas = Based on all deck areas of 8031sf including concessi.ons = 535 occupants 3. Total number of occupants at the viewing sLands = 70 occupants 4. Occupant load of the offices and accessory areas that would egress through the pool area and deck = 8 occupants 5. TOTAL NUMBER OF OCCUPANTS FOR POOLS, DECK, VIEWING AREA and ACCESSORY SPACES ~ 1150 occupants 6. Number of exits as directed by IBC Table 1005.2.1 Four exits are required according to Section lBC Table 1005.2.1. Five exits have been provided. 7. Common path of egress travel per lBC Section 1004.2.5 The path of egress travel complies with this section. 8. Egress width of each doorway per lEC 1003.2.3. The building is fully sprinklered. The total required exit width for the Natatorium Space is 172 inches. The total exit width provided from Lhis space is 288 inches. We hope this additional information clarifies your concerns. Please do not hesitate to CODLact our office with any additional question. Cordially: Frank Parisi, AlA Associate Williams Architects 450 East Gundersen Carol Stream Illinois 60188 Phone 1-630-344-1035 Fax 1-630-221-1220 -----Original Message---~- From: Oehs, James A [mailto:JOchs@carmel.in.gov] Sent: Monday, January 23, 2006 9:18 AM To: Kent: Forman Cc: dbowden@summitconst.com; Frank Parisi; Steve W. Mihelich; Blanchard, Jim E Subject: RE: Bather Loads Kent, Our concern is why has the occupant load required in the building code Table 1003.2.2.2 (right hand column, 4th category up from the bottom) Decks, 15 gross not included? 1 III sr . ~ Please provide the following information for the INDOOR pools and deck only. 1. Total number of occupants for the indoor pools. 2. Total number of occupants for the indoor pool deck areas. 3. Total number of occupants at the viewing stands. 4. Occupant load of the offices and accessory areas that would egress through the pool area and deck. 5. TOTAL NUMBER OF OCCUPANTS FOR POOLS, DECK, VIEWING AREA and ACCESSORY SPACES. 6. Number of exits as directed by IBC Table 1005.2.1 7. Co~~on path of egress travel per lEC Section 1004.2.5. 8. Egress width of each doorway per tEC 1003.2.3. Please remember all code references is from the 2000 lBC with Indy Amendments. I have spoken to Bob Robertson at the State of Indiana Building Servi.ces ana he has concurred with the above requirements. Jim Ochs, C.B.a. -----Original Message-~~-- From: Kent Forman [mailto:kforman@gdhcm.com] Sent: Monday, January 23, 2006 8:54 AM To: Oens, James A Cc: dbowden@sumrnitconst.comi FParisi@williams-architects.coffii SWMihelich@williams-architects.com Subject: Bather Loads << File: TEXT.htm >> << File: Appendix B update no.2.doc >> Jim; Please find attached the corrected bather loads for both the i~door and ou~door aquatics areas. Please review and advise if chis information answers your questions from last week's inspection. Thanks; Kent Forman GDH 317-208-9142 2