Loading...
HomeMy WebLinkAboutA010-FRONT ELEVATIONBRICK and STONE LINTEL SCHEDULE 48" HIGH SPAN WINDOW *STONE*BRICKAll Lintels: 4" Minimum bearing required each end * Brick is based on 40psf and Stone is based on 60psf ** Any lintels not described by the above parameters shall be specifically designed. LINTEL SIZE36" HIGH ABOVE Up to 6'-0" Up to 8'-3" Up to 9'-3" Up to 16'-3" Up to 6'-0" Up to 8'-3" Up to 9'-3" Up to 16'-3" L7 x 4 x 3/8 L8 x 4 x 1/2 L8 x 4 x 1/2 L6 x 4 x 5/16 L5 x 3 1/2 x5/16 L3 1/2 x 3 1/2 x1/4 L7 x 4 x 3/8 **per Design L5 x 3 1/2 x5/16 L4 x 3 1/2 x 1/4 L7 x 4 x 3/8 **per Design **per Design**per Design L6 x 4 x 3/8 L8 x 4 x 1/2 ---- ---- -------- ---- ---- -------- ---- ---- ---- ---- ---- ---- ---- ----3'-2 7/8"14 12 PAD OUT WALL -SEE DETAIL A/7.02 8" TRIM EXTERIOR BRACKET D2 BRICK SOLDIER (FLUSH) SEE RAFTER TAIL DETAIL B/7.02 CAST STONE SURROUND (SEE DETAIL C/7.02) BRICK SILL ALIGN ROWLOCK W/ BOTTOM OF WINDOWS DOUBLE BRICK ROWLOCK (PULL 3/4") BRICK VENEER CAST STONE SURROUND (SEE DETAIL C/7.02)ELEVATION 'D' PAD OUT WALL -SEE DETAIL A/7.02 14 12 14 12 STRUCTURAL STONE VENEERBRICK VENEER AT RECESSED ENTRY AND INSIDE OF WALL OPENINGS SYN-BOARD (TYP.) HORIZONTAL SIDING AT RETURN ABOVE GARAGE STRUCTURAL STONE VENEER AT RETURN RESIDENCE FOR:Sheet InformationHouse Name: Series: Plan No.: Job Number:Drawing Date: Coord Name: Coord Phone: Drawing Scale: 1/8" = 1'0" Contract Drawn By: ( ) The Drees Company. All Rights Reserved. Space for Architect Seal 900 East 96th Street, Suite 100, Indianapolis, IN 46240 Phone: [317] 347-7300 Born on Date: CDs Drawn By: Copyright © LONBERGER 14589 AUTUMN WOODS INDIANAPOLIS GALLERY HOMES IGA-0575-00 11/15/22 M. HYATT SERIES_NM PLAN_NM 6.01 Elevation "D" Front Elevation 859.578.4290 the CRESTWOOD LJR 04/08/2016 BLC 2016 2021 Key Notes: 1 2 3 4 General Notes: 1. REFER TO SHEET 0N.1 FOR GENERAL NOTES. 2. ROOFING MATERIAL PER SELECTIONS. -- -- -- -- TYPICAL TRIM: 6" (ALL SIDES) (FRONT ONLY, UNLESS OTHERWISE NOTED) 8" 01/11/23