HomeMy WebLinkAbout06070027 Site Plan
"
~~.
Scmeider
The Sclmeider Corporation
8901 0liI Avenue
Iliotmic Fort H.m.o.
Tnoill."'\P"IiI, lDdilma 46218-1037
317-826-7100
317-826-7200 FAX
~
3urnyiJ>(
LandJcape Uchitocture
GIS 'US
Geology
Plot Pion Legend
[]QM] Proposed Grode,
000.0 Existing Grodes
__ 000,0-- Contour Grade
* Appro,. Loterol Location
- I - Sanitary Sewer Lines
-IT- Storm Sewer Lines
- 1,/ - Water Service Lines
- - - - - - - Sub-Surface Drain Lines
. Manhole (Sanitary or Storm)
. Beehive Inlet (Storm)
III Curb Inlet (Storm)
D End Section (Storm)
.... Fire Hydron!
- 0 0 0 _ 0 0 0 - Flow line-of.swole- -
Th.is Plot Plan Prepared Far.
Silver Thome Homes
Lot # 29, contoining 14,172 S.F.i, in
Aberdeen Bend Subdivision
Instrument # 200500066134
P.C. # 3, Slide # 739
HAMILTON COUNTY, CLAY TOWNSHIP
12786 TRAM LANE (50' R/W)
Cormel, IN 40032
Prepared Date: 06/22/06 By. KAG
Community Restrictions:
Side Yard~ N/A --
Rear Yard ~ 25'
Aggregate ~ 30'
Zoning ~ SI. I..'
Silvertharne Ho';'es, LLC.
Finished Floor Elevotion Information
Pod Grode ~ 914:2 per plan
Pod Grade + 1.0' ~ Garage m (915.2)
Garage m + 0.5' ~ Residential m (915.7)
Residential FFE - 10.0' ~ Basement m (905.7)
"
Nate : The garage finished floor elevotion is
2.6' above the curb at the drive, per plan.
Nate: Sanitary Sewer
Tap of Casting Information
Upstream Manhole, TC~ 913.80
Downstream Manhole, TC~913.00
per plan.
Ground Caver Caiculatians:
Drive ~ 1,458 SFi
Public Walk ~ 392 SFi
Private Walk ~ 189 SFi
Seed ~ n/a SFi
;9/.1 Sad ~ 1O,429 SFi, whale jIlrd.
.~
.
.'-
FLOOD HAZARD STATEMENT
CERnFICA nON
,,\\1\\\\\\1111111111",,/1.
~"",c. L /'l"l,>~
#~~~..,....:"..ll;Ph~
~ ss"'~(,\SNTE:~~"'.~A~
~~""Q:- 0 O\;o~
I ( 50303 ) )
% .... STATE OF .... ~
~ <";;>(IvOI A~~""'~ ff
~::{f '''S'UR~\~
1i/"IIII/i11I1II1\\\\\\I\\~
Oo-lF-v
This drawing is not Intended to be represented os 0 retracement or
original boundary survey, a route survey, or 0 Surveyor Location Report.
FLOOD HAZARD STATEMENT
The accuracy of any flood hazard data shawn on this plat plan is
subject to map scale uncertainty and to any ather uncertainty In
location or elevation on the referenced flood Insurance rote mop.
ALL of the within described land DOES NOT UE within that special
flood hazard zone A as said land plats by scaie on
community-panel 1180080 0205F of the flood Insurance rate
maps far Fishers, IN (maps dated Feb, 19, 2003).
/
Nate:
This drawing is bosed on construction plans or record drawings,
and is not based upon a field survey, The Schneider Corporation
does not warrant the accuracy or sufficiency of this information.
Contractors should "erify existing conditions prior to any
construction. Any discrepancy found on this drawing should be
reported to The Schneider Corporation Immediately. failing to do
so results in the contractors assumption of 011 liability.
LOT# 29
VB06,0056721
Detail of twica! Ground
Water flow pattern for
individual lots.
~
~
=~=
~
Assumed North
Scale: I" ~ 30'
Note: Builder to ensure
positive drainage away from
structure(s).
ABB109
TC=913.00
PER PLAN
REVISION #1
ADDED F.P., MADE DECK
LARGER & SOD WHOLE YARD
VB06.0057449
07106106 - KAG
Note: The contractor is to: maintain a
minimum distance of ten feet (10')
between the sanitary sewer 'and water
line laterals.
PLEASE NOTE THAT THE STRAIGHT UNE SLOPE
OF THE DRIVl:WA Y FROM THE GARAGE FINISHED FLOOR
ELEVATION TO THE TOP OF THE CURB AT THE CENTER
OF THE ORIVl:WA Y EXCEEDS 5~ AS PROPOSED. THIS SLOPE
is BASED ON THE REQUIRED MINIMU~ GARAGE FINISHED
FLOOR ELEVATION AND !HE EXISTING TOP OF CURB ELEVATION.