Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
A101 - Floor Plan
1'-8"OUT to OUT FRAMINGSEALANT, TYP MFGR'D STONE @ LOW PIER BEHIND STONE, 1/2" APA RATED OSB ON PIER FACE (NOT NEEDED OVER END FRAMING) STONE VENEER BACKUP PER G5 / A401 ANCHOR w/ HGA10 CLIPS @ TOP & BTM OF EA STUD LENGTH (OUTER STUDS ONLY), SEE H3 / A401 THIN BRICK PER ELEVATIONS STONE SILL PER ELEVATIONS H3 A401 D 3 4 7 5 E 1A 1 4B 4A 6 E C C 2 8 B7A202H7A202TYPH3A401H6 A402 2 FS-1C2A104 H1A401A1 A104A4A1 0 4 TYPH3A401H4A401D2 A104 B5A202D4 A104 A7 A202 SIM H4 A401 H2 A103A2A104A3A104H2A103 C3 A104D3A104 GAS METER FDC NOTE: VERIFY UTILITY ROOM EQUIP. w/ MEP DWGs FLUSH ENTRY (ADA THRESHOLD) 2% MAX. SLOPE IN ANY DIRECTION AT STOOP GUARD RAIL, PER A1 / A201 BABY CHANGING STATION INSTALL TYPE K FIRE EXT., PER SPEC TO BE w/ IN 30' OF ALL COOKING EQUIP. VERIFY # REQ'D & LOCATION(s). NOTE: VERIFY ALL KITCHEN EQUIP. w/ VENDOR & KITCHEN EQUIPMENT PLAN ON SHEET FS-1 GRAB BARS GRAB BARS PROVIDE BLOCKING FOR ALL WALL MOUNTED EQUIP., TYP. COORD w/ FOOD SERVICE SUPPLIER ALL TOILET RM WALLS TO BE FULL HT TO STRUCTURE ABOVE w/ FULL HT SOUND BATT INSUL. SEE TOILET ROOM ELEVs ON SHEET A104 LEVEL ENTRY (ADA THRESHOLD) REQ'D AT STOOP 14 1/2" WIDE REFRIG. CHASE. NO OTHER TRADES THIS SPACE BOLLARD PER H2 / GD101, TYP. OPERABLE SLIDING PANE H4 A101 E6 A105 SEE DTL G4 / A104 FOR LAV FRAMING REQM'TS H2 A101 TYP OMIT RIGID INSULATION BTWN WALL FRAMING AND END OF HALF WALL TO ALLOW STUD-TO-STUD CONNECTION BABY CHANGING STATION 14" DEEP P. LAM. IT EQUIP SHELF, AT 96" AFF. BY GC. INSTALL SEMI-RECESSED FIRE EXTINGUISHER, "FEC-1" PER SPEC. VERIFY # REQ'D AND LOCATION(s). OFFICE FURNITURE PROVIDED BY OWNER. G.C. TO COORDINATE INSTALLATION AND CONFIRM LAYOUT, CONFIGURATION & SELECTIONS WITH OWNER. SHELVING BY FOOD EQUIP. SUPPLIER, TYP T/ STUDS TO BE BARE @ 36" ABOVE FINISH FLOOR. FSEC WILL PROVIDE STAINLESS STEEL CAP PLATE/ SHELF. PROVIDE ROUGH OPENING (BARE STUDS) FOR PASS THROUGH. COORD w/ FSEC; SEE ALSO FS-1. SILL @ 36" AFF. HEIGHT TO BE 40" SEE SHEET FS-1 FOR FURNITURE LAYOUT AND SEAT COUNT SEE GD101 FOR DUMPSTER ENCLOSURE PLAN EMPLOYEE COUNTER: SOLID SURFACE w/ BRACKETS BY G.C. SEE F3/A104 2-LEVEL HANGING ROD w/ SHELF ABOVE BY GC SEE D1/A104 SOLID SURFACE WALL CAP AND FLOATING TO-GO COUNTER 1" TOILET PARTITION ELIMINATE OFFSET & ALIGN FRAMING IF NO CI 6"23'-7"10'-10"6'-8" HOLD5'-4 1/2"ROUGHOPENING11'-6 1/2" MIN24'-2 1/2"HOLD 23'-11" MIN CLEAR (FINISH TO FINISH)9'-7 3/4" WALL FR'G MUST ALIGN w/ GIRDER TRUSSES ABOVE, SEE ROOF STRUCTURAL PLAN 7'-0" 3'-0 1/2"6'-9 1/4" 11'-0 1/2"6"7'-9 1/2"11'-0 3/4"6'-2"20'-0"2'-0"2'-0"10'-9"40'-8"16'-3 1/2"3'-10"28'-8 1/2"5 1/2"5 1/2"7'-0 1/2"20'-8 1/2" 4'-11 3/4"20'-7"7'-6 1/2"4'-2"3 1/2" 5'-5" 3 1/2" 10'-0" 3 1/2" 8'-1 1/2"7'-6"8'-8"7'-3 1/2"5 1/2"3'-1"4'-4"3 1/2"6'-4" 2'-11 1/2" 3'-4" 2'-1 1/2"4'-0 1/4"7'-3"5'-8 1/2"1'-5" 7'-4" 13'-5"1'-8"8'-10" 1'-8" 5 1/2" 3 1/2"2'-5"1'-5" 10'-2"13'-5 1/2"5 1/2"22'-5 1/2"5 1/2"5 1/2" 5 1/2" 6'-4" 2 1/2" 6'-11"5 1/2" 48" MIN5 1/2"2 1/2"5 1/2"2'-4"5 1/2"3 1/2"5'-2"3 1/2"1'-1 1/2"5'-6 1/2"5'-0 3/4"5 1/2" 13'-5"2'-0"2'-0"5 1/2"2'-9"3 1/2" 6'-5 1/2" 4'-8 1/2" 49'-0" 1'-8" 13'-5"1'-8" 6'-4" 7'-10" 9" 13'-5"2'-0" 9" 1'-5" 2'-0" 13'-9" 5'-8 3/4"5'-6" MIN CLEAR2'-10"3 1/2"16'-4" 7'-7 1/4" 2'-9 3/4" 6'-1" 2'-9 3/4" 5 1/2" 6'-11" 3'-6"19'-5 1/2"5'-8 1/4"3 1/2"2'-4" 5'-9" 5'-5" MIN CLEAR 5'-7 1/2" 5'-5" MIN CLEAR 5 1/2" 7'-1 1/4" 3 1/2" 5'-0 1/4" 18" MIN 2'-0" 5 1/2" 5 1/2"48'-10"8"3'-0" 3 1/2" 11'-0"3 1/2"5'-3 1/2" 3'-0"4"8"3 1/2"8'-10 1/2"3 1/2"2'-0"10'-9"6 1/2" 1" OFFSET 1" OFFSET 6'-10"3 1/2"11'-3"3 1/2"5 1/2"14'-1 3/4"16'-7 3/4"2'-4"5'-5"1'-5" 36'-8" 93'-6" 5'-1" 8'-0" 9'-0" 8'-0" 1'-8" 6'-7" 3'-8"3'-8"3'-5" 3'-2" 3 1/2" 15'-1" 14'-10"2'-0"2'-0" 4'-4"5'-0" 93'-6" 5'-1" 3'-5"8'-0" 1'-8" 3'-8" 3'-8" 2'-0" 3'-8 1/2" 4'-4" 8'-7" 3'-6 1/2" 15'-2 1/2" 7'-8 1/2" 3 1/2"5'-8 1/2"1'-7" 1'-9"3 1/2"4'-6"1'-4"1 13 1/2"6"EQ.6"3 1/2"3 1/2"EQ.3'-6"10"5'-6 1/2"6'-7 3/4"2'-4 1/2"5'-6 3/4"1'-4"5'-6" 1" 15'-1"1" OFFSET1"2 5 2 5 2 5 5 6 4 1 2 2 5 2 7 5 6 7 4 4 4 4 4 2 2 4 4 4 4 4 4 4 4 2 7 1 1 7 4 4 4 4 5 1 A1 A B B G1 A101 TYP1'-8"4'-0"8'-0"1'-4"4'-0"1'-8"42'-2"4'-0"2'-0"2'-0"1'-9"1'-6"2'-0"2'-0"1'-6"1'-6"1'-6"1'-9"7'-3"20'-4"7'-3"WH MDP CT CAB A2A103.1PANEL BPANEL A7 1/2" 5 1/2" 4 19'-9 3/4" +1" IF NO C.I.7'-2 1/4" TO BLKHDFRAMING; VIF & COORD14'-9"+1" IF NO C.I.2" CLEAR MIN 2" CLEAR MIN2" CLEAR MIN 2 2 2 2 2'-11 1/2"2A 5'-6"BP ON WALL H2A4014'-8 1/2" 4'-0" EIFS PANEL 6'-4 1/2" 8'-5 1/2" 4'-0" EIFS PANEL 4'-8 1/2" 4'-8 1/2" 4'-0" EIFS PANEL 4'-8 1/2"4'-8 1/2" 4'-0" EIFS PANEL 6'-4 1/2" 67" Ø CLE A R 30"x52" CLEARFEC-1FE-2 30"x52" CLEAR FE-1 48" x 60" MINENTRY PATIO 103 C C B 8'-0"5 1/2"4 1/2"2'-7"4'-0"1'-8"3'-4"1'-2"9 1/4" 19'-11" 3'-4" 6'-0" 3'-4"3'-1" 3'-0"3 1/2"1'-2"5'-2"1'-2"24'-10" 3'-9 1/2" 3'-0"7'-2 1/2"12'-4 1/2" 3'-1" 4'-2 1/2" 7'-8 1/2" 6'-0"31'-0" 16'-7 3/4" 12'-4" 5'-4" 5'-8"4'-5" 3 1/2"6'-4" 3 1/2" 13'-0"3 1/2" 7'-10 1/2"1'-2 1/4"3'-7 1/4"2'-4 3/4"3'-7 1/4"1'-2 1/4"11'-11 1/2"20'-7"3'-4" 6'-4"3'-4" 3 1/2"18'-0"13'-2 1/2" TO CENTER OF TABLE FROM FACE OF GYP. BD.15'-1 1/2"TO CENTER OF TABLE FROM FACE OF GYP. BD.2B 1'-4" 9'-2" 1'-4" 1'-4" 9'-2" 1'-4" PATIO PIER PER F8 / S101. CONFIRM QUANTITY & LOCATIONS SITTING WALL PER G7 / S101. PRESSURE WASHER HOOK UP & SWITCH FOR POWER WASHER. PRESSURE WASHER HOOK UP & SWITCH. PRESSURE WASHER HOOK UP & SWITCH FOR POWER WASHER. PRESSURE WASHER LOCATION - CONFIRM & COORDINATE w/ OWNER 4 4 WATER SFTNR BRINE TANK WATER SFTNR H1 A101 PRESSURE WASHER HOOK UP & SWITCH FOR POWER WASHER. 6'-9 1/2"7'-1 1/4" 5 1/2"1 2'-11 1/2"2'-6"1"33'-7 1/2" 5 1/2" 9'-0 1/2" SEE E6 / S401 FOR HALF WALL POST & FASTENING DETAIL 1'-0"1'-0"1'-0"SEE E7 / S401 FOR HALF WALL POST & FASTENING DETAIL 1'-0" SEE E7 / S401 FOR HALF WALL POST & FASTENING DETAIL 30"x52" CLEAR1'-0"103 104 111 118 117 116 115 113 108 110 106 109 105 101 102 112 114 107 119 ENTRY DRIVE-THRU SERVICE SUNDAE SERVICE MOP ROOM OFFICE UTILITY ROOM DRY GOODS DISHWASHING WOMEN COOLER FREEZER CUSTOMER SERVICE ENTRY TOILET HALL CUSTOMER ORDER AREA DINING DRINKS & CONDIMENTS KITCHEN PREP AREA MEN 4'-8 1/2"4'-8 1/2" 4'-0" EIFS PANEL 4'-0" EIFS PANEL 2'-5"2'-5" MAIN ENTRY DRIVE-THRU REAR RIGHT SIDE LEFT SIDE FRONT SEE SITE PLAN FOR NORTH ORIENTATION WALL SUBSTRATES NOTES: 1. SEE FLOOR PLAN FOR FRAMING MATERIALS 2. INSTALL FIRE BLOCKING IN EACH STUD CAVITY @ CEILING LEVEL. FIRE BLOCKING SHALL BE: · NOMINAL 2x TO MATCH DEPTH OF CAVITY IN WOOD STUDS, OR · METAL TRACK SECTION MATCHING CAVITY DEPTH TO SUPPORT MINERAL WOOL FIRE SAFING IN METAL STUDS, OR · MIN 16" HEIGHT UNFACED BATTS, FULL DEPTH OF CAVITY, MECHANICALLY SECURED (ANY STUD TYPE) 5/8" CEMENT BOARD 8"5/8" CEMENT BOARD 5/8" CEMENT BOARD 8"6 5 421 CONCRETE SLAB ALL TYPES, U.N.O.6"3 NOT USED 7 5/8" CEMENT BOARD 8"5/8" CEMENT BOARD 5/8" PLYWOOD 5/8" PLYWOOD GLUED & SCREWED @ BOOTH TABLE AREAS 5/8" CEMENT BOARD5/8" GYPSUM BD WALL FRAMING PER FLOOR PLAN 2x10 @ BOOTH TABLE BRACKET LOCATIONS. CENTER ON UPPER FASTENERS 7'-0"1/4" CEMENT BOARD 3/8" PLYWOOD (BEHIND CEMENT BOARD)4'-0"6"6"5/8" GYPSUM BOARD LAY IN CEILINGLAY IN CEILINGLAY IN CEILING CLG. HEIGHTS & MAT'L VARY FIREBLOCKING BATTS MUST BE CONT. FOR 16" LENGTH. INSTALL FIRE BLOCKING @ CEILING1'-4" MINIMUMIF BATTS ARE USED5/8" GYPSUM BD 6"ROOM NUMBER ROOM NAME WINDOW TYPE DOOR NUMBER DETAIL NUMBER SHEET NUMBER SYMBOL LIBRARY A7 A201 H4 A401 DETAIL NUMBER SHEET NUMBER MASONRY PER WALL SEC'TNs STUD SPACING TO BE16" O.C. MAXNON INSUL. METAL STUD WALL INSULATED METAL STUD WALL EIFS (EXTERIOR INSUL. FINISH SYSTEM) THIN BRICK VENEER C 2A DINING 101 GENERAL NOTES CONTINUOUS INSULATION (CI) AT EXTERIOR WALLS IS REQUIRED FOR THIS PROJECT; INSTALL ON INTERIOR FACE OF STUDS PER WALL SECTIONS. DIMENSIONS SHOWN ARE FACE OF FRAMING TO FACE OF FRAMING, UNLESS NOTED OTHERWISE. FOR INTERIOR WALLS WHICH INTERSECT EXTERIOR WALLS, ADJUST FRAMING DIMENSIONS ACCORDINGLY TO ACCOUNT FOR INSTALLATION OF RIGID, CONTINUOUS INSULATION.ALL WALLS w/ WOOD BLOCKING SHALL HAVE FIRE BLOCKINGAT THE CEILING LEVEL AS NOTED PER WALL SUBSTRATES.INSTALL DRYWALL CONTROL JOINTS AT 25'-0" O.C. MAXIMUMHORIZONTALLY OR VERTICALLY AS REQUIRED. ALIGN WITHEDGE OF DOOR JAMBS WHERE POSSIBLEINSULATED WOOD STUD WALL NON INSUL. WOOD STUD WALL 2'-6" METAL STUDS AT 16" O.C. 4'-6" METAL STUDS AT 16" O.C. BATT INSULATION FULL HT TO BTM OF ROOF TRUSSES 6" 3 5/8"3 5/8"3 5/8"2'-0"2'-0"SEALANT, TYP MFGR'D STONE @ LOW PIERS THIN BRICK A8 A401 BEHIND STONE, 1/2" APA RATED OSB ON PIER FACE (NOT NEEDED OVER END FRAMING) STONE VENEER BACKUP PER G5 / A401 FLOOR PLANFLOOR PLAN SCALE : 1/4" = 1'-0" A101NEW CULVER'S RESTAURANT431 E Carmel DriveCarmel, IN 46032County of HamiltonDate:Revision:5-25-2022OLLMANN ASSOCIATES ARCHITECTS, P.C.200 South State StreetBelvidere, Illinois 61008815-544-7790 Phone© 2022K&J INVESTMENTS XVI, LLC1448 Conner StreetNoblesville, IN 46060Bob Goins: bgoins@indyculvers.com317-770-4656OWNER:Culver Franchising System, Inc.1240 Water StreetPrairie du Sac, WI 53578608-643-7980®2020-159 © OAA All rights reserved; any copying, transmittal or disclosure subject to OAA written approval. E5 FRAMING DETAIL SCALE : 3/4" = 1'-0" TYPICAL PIER CORNER PIER SCALE : 3/4" = 1'-0"H1 H2 H4 SCALE : 3/4" = 1'-0" NOTE: ALL GYPSUM BOARD SHALL BE FASTENED TO STUDS WITH SCREWS; DO NOT FASTEN WITH NAILS. 01/13/23