HomeMy WebLinkAboutA105 - Roof PlanH1A401H2A401H2A401DRIVE-THRU CANOPY SNOW GUARDS CURVED METAL PANELS ENTRY CANOPY SNOW GUARDS @ 8" - 12" FROM ROOF EDGE (BOTH SIDES - TYPICAL) CURVED METAL PANELS H7A402AT RUNNER CANOPY AND VEST ROOF: GUTTER w/ FIELD-LOCATED DOWNSPOUT(S) REMOTE ICE MACHINE COMPRESSOR; (2) SUCH. VERIFY LOCATION w/ FSEC H3A401TYPH4A401SIMH4A401SIMFAN RTU-1 REFRIGERATION CHASE ENCLOSURE w/ GALVANIZED METAL ROOF CAP, SEE H6 / A105 GRIDDLE HOOD EXHAUST FRYER HOOD EXHAUST RTU-2 COOLER COMP FREEZER COMP H6 A401 H3A401H4A401TYPTYP3'-0"ROOF LADDER- SEE DETAIL H8/A105 RDRD FULLY ADHERED SINGLE PLY MEMBRANE OVER MIN (2) LAYERS RIGID INSULATION TO PROVIDE MIN OVERALL R-VALUE OF 25, OVER SHEATHING WALKWAY PADS, TYP OVERFLOW SCUPPER, TYP. COORD. w/ PLB'G PLAN EIFS MEMBRANEEIFS MEMBRANETYPICAL HIGH PARAPET RETURN WALL FINISHES LOW PARAPET HIGH PARAPET LOW PARAPET HIGH PARAPET LOW PARAPET ROOF MEMBRANE TO BE TAN @ MAIN ENTRY AND VERTICAL PORTIONS OF MAIN ROOF, AND ANY OTHER POTENTIALLY VISIBLE AREA. BALANCE OF MEMBRANE TO BE WHITE. HIGH TOWER LOW PARAPET REFRIGERATION LINE PENETRATIONS FOR WALK-IN COOLER & FRZR COOLER & FRZR POWER PENETRATION POWER PENETRATION RD 1/4" PER FOOT1/4" PER FOOTB6/C6 S401 TYPICAL H6 A401 SIM H3 A401 6'-6" 3'-1" 2'-10" 7'-0" 2'-9"1'-8"1'-0"HIGH PARAPET COMPRESSOR DISCONNECTS3'-9"1'-8" 1'-8" 38'-2"7'-6"1'-1" SEE GD101 FOR SHED ROOF CUSTARD COMPRESSORS FIRE BLOCKING AT CORNICE - SIDE OF PIER SEE A7/A402 TYPICAL HB-2 HOSE STATION NO. 502 TUBULAR RAIL LOW PARAPET ACCESS LADDER WITH ROOF OVER RAIL EXTENSIONS, PRE-FINISHED BLACK 3'-6"TOP OF PARAPET EQUAL TOP OF RUNG, FIELD VERIFY ELEVATION 7" MIN8'-2"1/8" ALUM PLATE SECURITY DOOR (PAINTED) w/CONTINUOUS ALUM HINGES AND LATCHALUM. TUBING PER MANUFACTURER MANUFACTURER'S ALUMINUM BRACKETS LAG INTO SOLID STUD BACKING, TYPICAL OSHA APPROVED ALUM RUNGS,SEERIGHT2'-0" 1 3/4" 1 3/4" 3'-0"4'-0"HASP TO BE @ 5'-0" BOTTOM MOUNTING BRACKETS TO BE FASTENED TO WALL, NOT SLAB 5'-0"MANUFACTURER'S ALUMINUM BRACKETS LAG INTO SOLID STUD BACKING, TYPICAL 1'-0"TYPICALMFGR'D STONE CONTINUES BEYOND PRE MANUFACTURER ALUMINUM LADDER AS SPECIFIED IN PROJECT MANUAL. TUBULAR ALUMINUM RAILS & EXTENSIONS 6"CORNICEPROFILEINSTALL THIN BRICK BEHIND LADDER -SEE ELEVATION2'-9"1'-6" INSIDE CLEAR 4 1/4" INTEGRAL DRIP EDGE, SEAL PROVIDE (3) 3" PVC SLEEVES FROM TOP PLATE OF WALL BELOW UP THROUGH CHASE ENCLOSURE ON ROOF TRUSS BEYOND PER MFGR (VERIFY CONFIGURATION) ITEM 505 PER FS-1 SCHEDULE: REFRIGERATION LINES (PROVIDED AND INSTALLED BY OTHERS)±5'-6", CONFIRM w/ REFRIGERANT PROVIDERHOW FAR UP WITHIN CHASE ENCLOSURETO EXTEND PVC TUBESPVC COUPLINGS AS REQ'D TO INSTALL TUBING & SECURE TO WALL FRAMING TOP PLATE 20-GA. GALVANIZED SHEET METAL COVER. VERIFY ALL DIMENSIONS PRIOR TO FABRICATING. INSTALL AFTER REFRIGERATION WORK ±10" OPEN @ END w/ REFRIG LINES ±1'-1"±8"5/8" CDX PLYWOOD OVER 2x4 SIDE FRAMING (NOT NEEDED OVER 2x12s AT ENDS) 2x6 BLOCKING BTWN TRUSSES AS NOTED ON FRAMING PLAN. ALIGN w/ 2x4 FRAMING FOR SIDEWALLS OF ENCLOSURE 2x4 FRAMING FOR SIDEWALLS OF ENCLOSURE w/ TOP & BTM PLATES. CONSTRUCT AFTER PVC TUBES HAVE BEEN SET HOLES IN ROOF DECK ALIGNED w/ HOLES IN TOP PLATE BELOW. SEAL AROUND PENETRATIONS IN ROOF DECK AND INSTALL INSULATION WITHIN ENCLOSURE AFTER REFRIGERATION LINE INSTALL AFTER SETTING CAP, SPRAY FOAM INSULATION AROUND REFRIGERATION LINES TO SEAL COMPLETE 2x12 END FRAMING FOR ROOF TOP ENCLOSURE OF REFRIGERATION CHASE. SET FRAMING ATOP ROOF DECK. FASTEN THRU DECK TO 2x6 BLKG, INSTALLED FULL PERIMETER OF ENCLOSURE BENEATH DECK. GIRDER TRUSS PER FRAMING PLANSEERIGHTWRAP MEMBRANE UP AND OVER SIDE & ENDWALLS; FASTEN TO TOP PLATES TOP PLATE. CUT HOLES FOR PVC SLEEVES AS NOTED ON H3 / A101 ±1'-9 1/2" COVER ROOF PLAN NOTES: CONTRACTOR TO VERIFY ROOF TOP UNIT SPECIFICATIONS AND TRUSS SIZE AND SPACING THIS PATTERN INDICATES TAPERED INSULATION; PROVIDE AS SHOWN OR REQ'D @ MIN. PITCH OF 1/4" PER FOOT VERIFY NUMBER OF ROOF DRAINS AND THEIR LOCATIONS w/ PLUMBING SHEET P101 G.C. TO LIFT UP TO ROOF ALL REFRIGERATION CONDENSING UNITS FOR THE FOOD SERVICE EQUIPMENT. EACH UNIT WEIGHS APPROXIMATELY 250#. COORDINATE DELIVERY TIMING WITH OWNER AND FOOD SERVICE EQUIPMENT SUPPLIER. PAINT ANY PIPING REQUIRED BY CODE NATIONAL ACCOUNT CONTACT DURO-LAST MEMBRANE SYSTEM: MARK SUMAN, NATIONAL ACCOUNT MANAGER mrsuman@duro-last.com 708-635-9928 CONTACT REP FOR APPROVED INSTALLERS. 3" PVC PVC COUPLING 8" LONG 3" PVC SLEEVE; VERIFY LENGTH ROOFING ROOFING BOOT BY ROOFING CONTRACTOR 8" MIN3" PVC SLEEVES THRU ROOF FOR REFRIGERATION AND ELECTRICAL LINES BY GC. COORDINATE AS NEEDED.36"PROVIDE LOOSE FITTINGS (DO NOT GLUE) FOR REFRIGERATION AND ELECTRICAL. VERIFY REQUIREMENTS ALIGN FACE OF STUDS w/ FINISH SURFACE. INSTALL AFTER REFRIGERATION LINES ARE SET. CUT HOLES IN TOP PLATE FOR 3" Ø PVC SLEEVES; CONFIRM LOCATION w/ REFRIGERATION CONTRACTOR1'-2 1/2" CLEAR STAINLESS STEEL CHASE COVER PROVIDED BY FSEC 4 1/2"4 1/2" METAL STUD WALL PER PLAN (ALL STUDS NOT SHOWN) A105 H6 TREATED 4" x 4" x 48" RAILS, PROVIDED & INSTALLED BY REFRIGERATION CONTRACTOR CONDENSING UNITS; PROVIDED BY FSEC - SET IN PLACE BY GC. INSTALL DOUBLE LAYER ROOFING MEMBRANE OR WALK PAD BENEATH RAILS. PROVIDE FULL COVERAGE GC SHALL COORDINATE REQUIREMENTS AND INSTALLATION WITH REFRIGERATION CONTRACTOR NEW CULVER'S RESTAURANT431 E Carmel DriveCarmel, IN 46032County of HamiltonDate:Revision:5-25-2022OLLMANN ASSOCIATES ARCHITECTS, P.C.200 South State StreetBelvidere, Illinois 61008815-544-7790 Phone© 2022K&J INVESTMENTS XVI, LLC1448 Conner StreetNoblesville, IN 46060Bob Goins: bgoins@indyculvers.com317-770-4656OWNER:Culver Franchising System, Inc.1240 Water StreetPrairie du Sac, WI 53578608-643-7980®2020-159 © OAA All rights reserved; any copying, transmittal or disclosure subject to OAA written approval. C6 ROOF PLAN;REFRIGERATION DETAILSROOF PLAN SCALE : 1/8" = 1'-0" A105RUNG LADDER SCALE : 1/2" = 1'-0"H8 REFRIGERATION CHASE SCALE : 3/4" = 1'-0"E6 REFRIGERATION CHASE SCALE : 3/4" = 1'-0" H6 PENETRATION DETAIL SCALE : 3/4" = 1'-0" E3 MOUNT DETAIL SCALE : 3/4" = 1'-0" F3 01/13/23