Loading...
HomeMy WebLinkAboutA109 - A402 - Wall Sections2-PIECE PRE-FABRICATED METAL ROOF EDGE & CONTINUOUS CLEAT BASE - TYPICAL BRUSHED ALUM. FASCIA BEHIND AND BELOW TYP. ROOF EDGE w/ DRIP EDGE AT BOTTOM6"VARIESR-21 BATT INSUL. AT EXT. WALLS, FULL HEIGHT IN STUD CAVITY, TYPICAL CONTINUE THERMAL BATTS MIN 12" ABOVE ROOF INSUL, TYP. DOUBLE TOP PLATE 10'-0" STANDARD WALL FRAMING HEIGHT10'-0" T/ WALL FR'G 2x6 STUDS @ 16" O.C., TYPICAL BELOW 10'-0" AFF U.N.O. PROVIDE 2x8 BLK'G BTWN TRUSSES; NAIL ROOF DECK TO 2x8 PER SHEAR WALL DIAGRAM, SHEET S102. TYPICAL CEILING HT & MAT'L VARIES; SEE CEILING PLAN END WALL TRUSSES PER MANUFACTURER CONT. 2x4s NAILED TO TOP CHORD OF TRUSSES PER H7 / S102 CONT. 2x6 FR'G OR TRUSS ENDEXTENDED AT HI PARAPET23'-2" T/ BLK'G HIGH PARAPET H8 A401 17'-10" TRUSS UPRIGHT WALL FINISH OVER SUBSTRATE OVER VAPOR BARRIER OVER CONTINUOUS INSUL. SEE A101 FOR SUBSTRATES AND FINISHES, TYP. 10'-0" TRUSS BEARING 7'-4" HEAD R.O. PIER BEYOND 0'-0" T/ SLAB 3'-2" T/ SILL TYPICAL U.N.O. 1/2" 2x6 STUDS @ 16" O.C., TYPICAL U.N.O.±1'-1"TRUSS EXTENSION 4'-0" STAINLESS STEEL COUNTER FLASHING SINGLE PLY ROOFING OVER MIN 2" TAPERED INSULATION INSTALLED OVER 5/8" APA RATED OSB INFILL 2x BLKG @ TRUSS ENDS, WRAPPED IN BRAKE METAL, TO MATCH CANOPY SIDES A8 A402 VENTED ALUMINUM SOFFIT w/ TRIMS AS REQ'D SEE H4/A401 FOR MORE INFORMATION GUTTER & FIELD LOCATED DOWNSPOUT EXTEND EIFS INSULATION UP FIT TIGHT BETWEEN TRUSS MEMBERS AND PLYWOOD DECK D8 A401 17'-10" T/ TRUSS UPRIGHT WHERE TRUSS EXTENSION PROTRUDES AS CANOPY BEYOND EXTERIOR FACE OF WALL, INSTALL GYP BD TO ROOF DECK-TYP. INSTALL 2x SOLID WOOD FIREBLOCKING AT LOCATIONS INDICATED ON ROOF PLAN AND EXTERIOR ELEVATIONS LOCATE BLOCKING ALIGNED w/ OUTER EDGE OF CORNER PIER FRAMING TYPICAL T/ WALL AND LADDER BLOCKING PER C8 / A401 BACKER ROD AND SEALANT STONE FULL HEIGHT TO PARAPET EAVE @ CORNER PIERS PIER FRAMING CLIP PER H1 / A101 NEW CULVER'S RESTAURANT431 E Carmel DriveCarmel, IN 46032County of HamiltonDate:Revision:5-25-2022OLLMANN ASSOCIATES ARCHITECTS, P.C.200 South State StreetBelvidere, Illinois 61008815-544-7790 Phone© 2022K&J INVESTMENTS XVI, LLC1448 Conner StreetNoblesville, IN 46060Bob Goins: bgoins@indyculvers.com317-770-4656OWNER:Culver Franchising System, Inc.1240 Water StreetPrairie du Sac, WI 53578608-643-7980®2020-159 © OAA All rights reserved; any copying, transmittal or disclosure subject to OAA written approval.WALL SECTIONS ANDDETAILSA402 FASCIA DETAIL SCALE : 3" = 1'-0" NOTE: SECTIONS ABOVE INDICATE TYPICAL (NON-SHEAR WALL) FASTENING FOR WALL SHEATHING. SEE SHEAR WALL DIAGRAMS ON SHEET S102 FOR SHEATHING FASTENING AT SHEAR WALLS. A8 WALL SECTION SCALE : 3/4" = 1'-0" H6 WALL SECTION SCALE : 3/4" = 1'-0"H7 DETAIL SCALE: 1 1/2" = 1'-0"A7 01/13/23