HomeMy WebLinkAboutE010 - SE201 Site Electric Details1. PROVIDE CONDUIT SPACERS EVERY 6 FEET. ELECTRICAL CONDUIT TRENCH DETAIL NTS4"MIN 6"6" MIN 4"2'-0"3'-0"SAND6"2'-6"MARKER TAPE 6"1'-0"PAVED AREAS LAWNED AREAS NOTES: ELECTRICAL CONDUIT SEE PLAN FOR QUANTITY GRANULAR BACKFILL COMPACTED GRAVEL PER PLAN ASPHALT PAVEMENT 4" TOPSOIL, SEED & MULCH 1 EQUIPMENT SCHEDULE SITE SIGNAGE/MENU BOARD SCHEDULE ITEM DESCRIPTION QTY TYPE VOLT PHASE AMP CONN. TYPE COMMENTS F MAIN FREESTANDING SIGN 1 NEW 115 1 16.0 DIR. 1) SIGN CONTROL 1 NEW MAIN SITE SIGNS ARE CONTROLLED VIA A TIMECLOCK WITH A PHOTOCELL OVERRIDE. THERE MAY BE TWO MAIN SITE SIGNS. VERIFY ALL SIGN REQUIREMENTS WITH SIGN CONTRACTOR BEFORE ROUGH-IN. G ELECTRONIC MESSAGE CENTER (EMC) 115 DIR.TWO INDEPENDENT 20.0 AMP CIRCUITS ARE REQUIRED FOR THE EMC. EACH CIRCUIT TO HAVE AN INDEPENDENT NEUTRAL. THERE MAY BE TWO EMC SIGNS. VERIFY ALL SIGN REQUIREMENTS WITH SIGN CONTRACTOR BEFORE ROUGH IN. 1) EMC CONTROL 2) COMMUNICATION CONDUIT EMC MUST HAVE CONSTANT 24/7 POWER. DO NOT SWITCH. PROVIDE AN EMPTY 1 1/2" CONDUIT, WITH SWEEPING 90s AND PULL BOXES, FROM OFFICE TO SIGN FOR COMMUNICATION LINES 1 NEW 1 NEW 1 NEW 2 @ 16.0 H SITE DIRECTIONAL SIGNS LOT 1.0 THERE MAY BE MORE THAN ONE OF THESE SIGNS ON THE SITE. VERIFY WITH SIGN CONTRACTOR BEFORE ROUGH IN. DIRECTIONAL SIGNS AS WELL AS MAIN SITE SIGNS ARE CONTROLLED VIA A TIMECLOCK WITH A PHOTOCELL OVERRIDE THERE MAY BE TWO MAIN SITE SIGNS. VERIFY ALL SIGN REQUIREMENTS WITH SIGN CONTRACTOR BEFORE ROUGH IN.1) SIGN CONTROL 1 NEW NEW 1115 DIR. 24" x 24" x 48" DEEP FOOTING FOR ORDER CONFIRMATION BOARD. SEE NOTE BELOW. NOTE: G.C. TO INSTALL ORDER CONFIRMATION BOARD FOOTING WHEN NO CANOPY EXISTS. SIGN MANUFACTURER TO INSTALL FOOTING FOR ORDER CONFIRMATION BOARD WHEN ORDER CONFIRMATION HAS A CANOPY. COORDINATE & CONFIRM w/ OWNER & SIGN VENDOR. CONDUITS TO MENU BOARD / BUILDING FOR POWER, COMMUNICATIONS, AND SENSOR LOOP. REQUIRED METAL FREE ZONE (4) REQUIRED SUPPORT STAKES G.C. TO INSTALL PREFABRICATED OWNER PROVIDED SENSOR LOOP. 12" - 18" BUILDING CURBTRAFFIC FLOW2'-0" - 3'-0" 4'-6" 2'-0"2'-0"2'-0"PLAN VIEW CONCRETE PAD AT DRIVE THRU LANE CROSS SECTION SCALE: 1/2" = 1'-0" ORDER CONFIRMATION BOARD (OCB) AND SENSOR LOOP PEDESTAL DETAILS COMPACTED GRANULAR FILL GRADE 2" MIN.2" MAXTEE IN SENSOR LOOP VERIFY ORDER CONFIRMATION SYSTEM BOLT PATTERN w/ SUPPLIER; BOLTS PROTRUDE 2" TO 2 1/2" ABOVE CONCRETE THREE CONDUITS INTO BUILDING. CONDUIT FROM SENSOR LOOP. STAKESCONDUITS EXTEND 4"-6"KEEP DRY DURINGCONSTRUCTIONCONCRETE CURB PER CIVIL BOLTSEXTEND2"-2 1/2"ANCHOR BOLT PATTERN BOLT SIZE: 3/4" x 16" - 24" LONG NOTES: KEEP CONDUITS AND ANCHOR BOLTS CENTERED ON CONCRETE PAD FOUNDATION NO SCALE CONCRETE FOUNDATION, COORDINATE REQ'MTS: PROVIDED BY SIGN SUPPLIER IF OCB INCLUDES CANOPY. PROVIDED BY GC IF OCB DOES NOT HAVE CANOPY. OCB CABINET CONDUIT ACCESS OPENING, CENTER ON FOUNDATION 8 3/4"3" 3 3/4"10"VERIFY ANCHOR BOLT PATTERN w/ SUPPLIER CONDUIT PURPOSE, SIZE, AND RUNS NO SCALE A = POWER 110 V / 20 AMP DEDICATED IG; POWER MUST REMAIN ON AT ALL TIMES. SIZE PER LOCAL CODE AND DRIVE THROUGH REQUIREMENTS ON SHEET SE101. B = MIC + SPEAKER + LOOP CONDUIT. 1" Ø TO BUILDING C = CAT 5 (DIRECT BURIAL) DATA CONDUIT. 1" Ø TO BUILDING D = INGROUND LOOP CONDUIT; 1/2" Ø TO LOOP. THIS CONDUIT IS SUPPLIED w/ THE LOOP. LOOP ELECTRICAL DATA SPARE B A C D SEE CONDUIT DIAGRAM ABOVE SEE CONDUIT DIAGRAM ABOVE SEE CONDUIT DIAGRAM ABOVE NEW CULVER'S RESTAURANT431 E Carmel DriveCarmel, IN 46032County of HamiltonDate:Revision:5-25-2022OLLMANN ASSOCIATES ARCHITECTS, P.C.200 South State StreetBelvidere, Illinois 61008815-544-7790 Phone© 2022K&J INVESTMENTS XVI, LLC1448 Conner StreetNoblesville, IN 46060Bob Goins: bgoins@indyculvers.com317-770-4656OWNER:Culver Franchising System, Inc.1240 Water StreetPrairie du Sac, WI 53578608-643-7980®2020-159 © OAA All rights reserved; any copying, transmittal or disclosure subject to OAA written approval. SE 201SITE ELECTRICAL DETAILS01/13/23