HomeMy WebLinkAboutE102 - Power & Communications PlanFEC-1FE-2 FE-1 ENTRY PATIO $$$$$$$$ENTRY DRIVE-THRU SERVICE SUNDAE SERVICE MOP ROOM OFFICE UTILITY ROOM DRY GOODS DISHWASHING WOMEN COOLER FREEZER CUSTOMER SERVICE ENTRY TOILET HALL CUSTOMER ORDER AREA DINING DRINKS & CONDIMENTS KITCHEN PREP AREA MEN DUMPSTER ENCLOSURE SHED KITCHEN FAN CONTROL CENTER(KFCC) MOUNTED ABOVE FINISHED CEILING. SEE CONTROL DETAIL & SCHEDULE NOTES & DETAIL 86 COORDINATE w/ SIGN SUPPLIER MENU BOARD ORDER CONFIRMATION BOARD (OCB) B43 1 1/2" DIA POWER1 1/2" DIA COMMUNICATIONS1 1/2" DIA POWER TO OFFICE 1 1/2" DIA COMMUNICATIONS TO OFFICE 1 1/2" DIA DRIVE IN SENSOR LOOP TO DRIVE THRU EXTERIOR ITEM LOCATIONS SHOWN FOR REFERENCE ONLY. REFER TO SITE PLAN FOR EXACT LOCATION OF EXTERIOR ITEMS. COORDINATE WITH SIGN PROVIDER. PROVIDE FOR TWO LOCATIONS WHERE / IF SHOWN ON SITE ELECTRICAL PLAN. SEE ALSO DRIVE THROUGH REQUIREMENTS, SHEET SE101 B-64 GFI 18" WP B-78 24" GFI B-81 GFI B-81 24" B-81 24" 24" GFI B-60 B-25 TELE B-23 B-64 18" WP GFI 44" WATER HEATER B-60 PROVIDE BONDING JUMPER FROM SERVICE ENTRANCE TO WATER SERVICE w/ SUPPLEMENTAL JUMPER AROUND WATER METER. PROVIDE BONDING JUMPER TO BUILDING STEEL JB 18" JB 36" MUSIC 102" JB B-64 18" GFIWP PROVIDE (3) JUNCTION BOXES HVAC EQUIP. CONTROLS NOTE: "ORDER CONFIRMATION" CIRCUIT REQUIRES POWER 24/7 JB "alarm" - FIRE SPRINKLER ALARM: COORDINATE w/ SPRINKLER DESIGNER GFICHIME DOORBELL PUSHBUTTON DBB-61 24" GFI A-83 MAIN PANEL JB B-50 JB B-83 B-60B-60B-60 B-78 B-78 60" 24" GFI B-61 GFI B-60 18" W B-57 110" 110" WIRELESS ROUTER CAT 5E OR 6 TO OFFICE PATCH PANEL DUCT SMOKE DETECTORS PROVIDED BY LENNOX SDD DEDICATED CREDIT CARD PHONE LINE (UNDER CABINET) GFI B-61 TVB-62 VERIFY ALL HEIGHTS & LOCATIONS WITH OWNER - TYPICAL SEE B3/E102 108" E 110"110" USB HC 102" B-50 B-60 36" CABLE 42" CABLE TV MAIN ENTRANCE CAMERA SYSTEM COORDINATE LOCATION WITH SURVEILLANCE SYSTEM PROVIDER JB JB B-50 LOCATE OUTLETS CLEAR OF OWNER FILE CABINETS. CONFIRM LOCATION w/ OWNER M EF-1 A-74 TV110"110" B-62 SGFIB-25 SURVEILLANCE SYSTEM MONITOR COORDINATE LOCATION WITH SUPPLIER PANEL A SURVEILLANCE SYSTEM MONITOR COORDINATE LOCATION WITH SUPPLIER TERMINATE SENSOR LOOP CONDUIT FROM MENU BOARD JB TERMINATE POWER & COMMUNICATION CONDUIT FROM MENU BOARD 18" 18" 18" B-61 24" 24" GFI B-61 GFI PANEL B WP GFI USB B-80 24"TVVERIFY ALL HEIGHTS & LOCATIONS WITH OWNER - TYPICAL EHWIRELESS ROUTER CAT 5E OR 6 TO OFFICE PATCH PANEL W DUCT SMOKE DETECTORS SDD B-78 24" WP GFI B-64 18" B-63 108" WP GFI B-64 18" USB B-59 USB B-59 B-63 108" WP GFI B-64 18" WP GFI B-64 18" B-78 24" USB B-56 44" USB B-56 44" B-57 102" B-62 110" USB B-56 B-62 72" B-62 72" USB B-62 46" S S S S S S S S DRIVE THRUKP USB 108" B-63 108" B-63B-59 USB B-59 USB B-56 USB 44" USB B-56 44" USB B-56 VERIFY ALL HEIGHTS & LOCATIONS WITH OWNER - TYPICAL B-59 USB USB B-59 24" 36" USB B-56 36" USB 36" USB B-56 36" USB B-56 B-56 B-56 CT CABINET WASHER / DRYER B-69,71 ELECTRIC DRYER: PROVIDE 3/4" CONDUIT w/ (4) #10 CU THWN B-67 WP GFI USB B-80 24" WP GFI USB B-80 24" WP GFI USB B-80 24" B-59 USBB-63 108" B-63 108" GFI B-50 84"B-61 JB B-41 120" INVERTER GFI B-83 RECIRC PUMP B-25 WATER SOFTENER JB BOOSTER PUMP B-79 48" B-50 USB B-61 48" USB B-61 48" JB 48" HOOD CONTROL INTERFACE; ALSO SEE E103 JB A-24 110" C CUSB B-59 24" JBA-25 B-63 108" B-63 108" USB B-59 B TELEVISION OUTLET JUNCTION BOX - DIRECT CONNECTION DUPLEX RECEPTACLE w/GROUND FAULT & WEATHERPROOF COVER DUPLEX RECEPTACLE w/GROUND FAULT - HUBBELL GFR5362SGW DUPLEX RECEPTACLE DUPLEX RECEPTACLE - CEILING SWITCH TELEPHONE LEGEND GFI 220 VOLT DEDICATED DUPLEX OUTLET w/ ISOLATED GROUND CHIME DOOR CHIME - EDWARDS C212-2L WITH CONTROL POWER TRANSFORMER DUPLEX RECEPTACLE w/ ISOLATED GROUND FOR ELECTRONIC EQUIPMENT QUAD RECEPTACLE HDMI CONNECTION ETHERNET CONNECTION CAT 5E OR 6 USB DUPLEX RECEPTACLE - WALL HUBBELL # USB15A5W WIRELESS ROUTER DOOR CHIME ENTRANCE PUSHBUTTONDB DEEP BOX WITH GANG PLASTER RING, 20 AMP DEADFRONT GFI & NEMA 5 20 AMP DUPLEX RECEPTACLE. LOCATE DEADFRONT GFI IN ELECTRICAL ROOM. PROVIDE WITH LABEL INDICATING DEVICE PROTECTED. DEDICATED QUAD OUTLET WITH ISOLATED GROUND COMMUNICATION JUNCTION BOX B29 PANEL DESIGNATION BREAKER DESIGNATION SDD DUCT SMOKE DETECTOR w/ REMOTE ALARM / TEST STATION. MOUNT ALARM / TEST NEAR FIRE ALARM PANEL OR AS DESIGNATED BY OWNER'S REPRESENTATIVE. PROVIDED BY LENOX BUMP BAR MONITOR CABLE GFI SINGLE RECEPTACLE w/GROUND FAULT - LEVITON X7891 E TVSWP GFI IG USB GFI W JB H C ID TAG SEE EQUIP. SCHED. ON E201 A-20 PANEL DESIGNATION BREAKER DESIGNATION DINING ROOM TV LOCATION PROVIDE RECESSED RECEPTACLES6'-9"CENTER OF MONITOR1 1/2" SLEEVE THRU TOP WALL PLATE FOR OWNER SUPPLIED HDMI CABLE MEDIA PLAYER OUTLET FOR MEDIA PLAYER CEILING COAXIAL CABLE TO MECH. ROOM ETHERNET CAT 5E OR 6 WIRE TO OFFICE PATCH PANEL OUTLET FOR TV / MONITOR HDMI / COAXIAL COMBO WALL PLATE DAILY FEATURE BOARD LOCATION ETHERNET CAT 5E OR 6 WIRE TO OFFICE PATCH PANEL OUTLET FOR MONITOR MOUNTING BRACKET 6'-8" CLEAR TO BTM MONITORMOUNT POWER & DATA BOXES ON EITHER SIDE OF WOOD STUD ABOVE BLOCKING ±2'-6" VIF STEEL STUDS 8'-1"6"3'-8" GENERAL NOTES: 1. MONITOR & MOUNTING BRACKET OWNER. 46"-47" MONITOR REQ'D. 2. BRACKET MOUNT & ANCHOR LOCATION MAY VARY; VERIFY w/ OWNER. 3. ELEVATION RELATES TO STANDARD PROTOTYPE 11'-0" CEILING HEIGHT ONLY. GC TO VERIFY LOCATION w/ OWNER FOR NON-TYPICAL CEILING HEIGHTS. WOOD STUDS7'-6"2'-0"2'-8" ±11'-0" VERIFY INSTALL 2x12 BLOCKING BTWN EXISTING STUDS IN THIS LOCATION USB OUTLET LOCATIONS @ TABLES3'-6" T/ TABLE120 HIGH TOP TABLES 108 STANDARD TABLES SEE PLAN FOR OUTLET ELEVATION AT HIGH TOP TABLES. OUTLET TO BE BELOW WAINSCOT TRIM; INSTALL HORIZONTAL IF REQ'D 4"CENTER ON TABLE MAIN ENTRY DRIVE-THRU REAR RIGHT SIDE LEFT SIDE FRONT SEE SITE PLAN FOR NORTH ORIENTATION NUMBERS REFER TO FOOD SERVICE EQUIPMENT DRAWING FS-1. EQUIPMENT SUPPLIED BY OTHERS; PROVIDE ELECTRICAL CONNECTION. PROVIDE CONDUIT AND POWER TO BUILDING SIGNAGE. SEE BUILDING ELEVATIONS FOR LOCATIONS. VERIFY WITH OWNER. PROVIDE CONDUIT AND POWER TO ALL SITE SIGNAGE. SEE SITE PLAN FOR LOCATIONS. VERIFY WITH OWNER AND SIGN VENDOR. COORDINATE CONTROL SEQUENCE FOR EMERGENCY SHUT-DOWN OF RTUs WITH HOOD PROVIDER AND FIRE SUPPRESSION SYSTEM PROVIDER. PROVIDE CONDUIT AND WIRING TO ELECTRICAL TRANSFORMER. PROVIDE TIMECLOCKS AND PHOTO CELLS FOR ALL EXTERIOR SITE LIGHTING AND EXTERIOR SIGNAGE KITCHEN RECEPTACLES TO BE HUBBELL GFR5362WTR & GFCI PROTECTED PER NEC 210.8.B.2. VERIFY LOCATIONS OF ALL DINING ROOM USB OUTLETS WITH OWNER AND EQUIPMENT SUPPLIER. ALL KITCHEN RECEPTACLE CIRCUITS TO BE GFI PROTECTED REFER TO DRAWING E104 FOR CASH REGISTER AND ORDERING SYSTEM POWER AND COMMUNICATION REQUIREMENTS PROVIDE CONDUIT, WIRE AND TERMINATIONS FOR CABLE TV, ETHERNET AND HDMI DEVICES VERIFY LOCATIONS WITH OWNER. MAIN PATCH PANEL LOCATED IN OFFICE. MINIMUM INTERNET SPEED: 10 MBS DOWN / 1 MBS UP RECOMMENDED INTERNET SPEED:50 MBS DOWN / 5 MBS UP MUSIC SYSTEM MUSIC SYSTEM FURNISHED AND INSTALLED BY OWNER'S SUPPLIER. SUGGESTED SPEAKER LOCATIONS SHOWN FOR REFERENCE ONLY. SUGGESTED MUSIC ZONES: 1 - GUEST TOILET ROOMS 2 - PATIO 3 - DINING ROOM SECURITY AND SURVEILLANCE SYSTEMS PROVIDE 115 / 1 D.O. FOR SECURITY SYSTEM, VERIFY LOCATION WITH OWNER. SURVEILLANCE SYSTEM FURNISHED AND INSTALLED BY OWNER'S SUPPLIER; CABLE INSTALLATION BY OWNER'S SUPPLIER. LOCATIONS SHOWN FOR REFERENCE. SECURITY SYSTEM FURNISHED AND INSTALLED BY OWNER'S SUPPLIER; CABLE INSTALLATION BY OWNER'S SUPPLIER. LOCATIONS SHOWN FOR REFERENCE. TELEPHONE TELEPHONE SYSTEM FURNISHED BY LOCAL PHONE COMPANY, INSTALLED BY CONTRACTOR. PROVIDE MINIMUM 3 LINES AT EACH LOCATION. COORDINATE MAIN PANEL AND JACK LOCATIONS WITH OWNER. S KP SYMBOL LOW VOLTAGE SYSTEMS NOTES MUSIC SPEAKER KEY PAD SURVEILLANCE CAMERA # GENERAL ELECTRICAL NOTES MENU BOARD ORDER CONFIRMATION BOARD (OCB) B43 1 1/2" DIA POWER1 1/2" DIA COMMUNICATIONS1 1/2" DIA POWER TO OFFICE 1 1/2" DIA COMMUNICATIONS TO OFFICE 1 1/2" DIA DRIVE IN SENSOR LOOP TO DRIVE THRU EXTERIOR ITEM LOCATIONS SHOWN FOR REFERENCE ONLY. REFER TO SITE PLAN FOR EXACT LOCATION OF EXTERIOR ITEMS. COORDINATE WITH SIGN PROVIDER. PROVIDE FOR TWO LOCATIONS WHERE / IF SHOWN ON SITE ELECTRICAL PLAN. SEE ALSO DRIVE THROUGH REQUIREMENTS, SHEET SE101 PROVIDE BONDING JUMPER FROM SERVICE ENTRANCE TO WATER SERVICE w/ SUPPLEMENTAL JUMPER AROUND WATER METER. PROVIDE BONDING JUMPER TO BUILDING STEEL NOTE: "ORDER CONFIRMATION" CIRCUIT REQUIRES POWER 24/7 "alarm" - FIRE SPRINKLER ALARM: COORDINATE w/ CABLE TV MAIN ENTRANCE PANEL A PANEL B CT CABINET INVERTER POWER AND COMMUNICATIONS PLAN SCALE : 1/4" = 1'-0" E102NEW CULVER'S RESTAURANT431 E Carmel DriveCarmel, IN 46032County of HamiltonDate:Revision:5-25-2022OLLMANN ASSOCIATES ARCHITECTS, P.C.200 South State StreetBelvidere, Illinois 61008815-544-7790 Phone© 2022K&J INVESTMENTS XVI, LLC1448 Conner StreetNoblesville, IN 46060Bob Goins: bgoins@indyculvers.com317-770-4656OWNER:Culver Franchising System, Inc.1240 Water StreetPrairie du Sac, WI 53578608-643-7980®2020-159 © OAA All rights reserved; any copying, transmittal or disclosure subject to OAA written approval. E2 POWER &COMMUNICATIONS PLANOUTLET ELEVATIONS SCALE : 1/4" = 1'-0"B3 01/13/23