HomeMy WebLinkAboutE104 - POS Systems PlanENTRY $$$$$$$$ENTRY DRIVE-THRU SERVICE SUNDAE SERVICE MOP ROOM OFFICE UTILITY ROOM DRY GOODS DISHWASHING WOMEN COOLER FREEZER CUSTOMER SERVICE ENTRY TOILET HALL CUSTOMER ORDER AREA DINING DRINKS & CONDIMENTS KITCHEN PREP AREA MEN L1 VERIFY ALL LOCATIONS w/ OFFICE LAYOUT & OWNER P.O.S. SITE CONTROL L4 L3 L2 IG A-27 K1 BUN STATION MONITOR POWER & COMMUNICATIONSK2 M1 M3 (1) CAT 5 (1) CAT 5 TO MAIN P.O.S. PANEL IG IG IG A-38 A-38 A-38 INSIDE CABINET ISLAND UP AGAINST TOP & AND BACK OF CABINET (TYP. 3 LOCATIONS) VERIFY ALL EXACT LOCATIONS & LAYOUTS WITH OWNER - TYPICAL C1 1-1/2" COMMUNICATION UNDER FLOOR TO VERTICALLY ABOVE CEILING ABOVE - VERIFY LOCATION PRIOR TO INSTALL M2 A-40 GFI IG F1 F2 N3 N2A-38 IG G2 G1 J1 H1 H2 I1 I2 N1 J2 C3 C2 SET STATION MONITOR POWER & COMMUNICATIONS FRY STATION MONITOR MIRROR - OPTIONAL F3 A-40 IG GFI SET STATION MONITOR POWER & COMMUNICATIONS GRILL STATION CUSTARD MONITOR (2) CAT 5 TO MAIN P.O.S. PANEL (2) CAT 5 (1) CAT 5 TO MAIN P.O.S. PANEL (1) CAT 5 (1) 50' VGA CABLE; OPTIONAL FOR MIRROR LOCATION A-40 IG GFI A-40 IG GFI A-40 IG GFI (1) 25' VGA CABLE (2) CAT 5 TO MAIN P.O.S. PANEL (10) CAT 5 TO MAIN P.O.S. PANEL (1) CAT 5 (2) CAT 5 TO MAIN P.O.S. PANEL A1 A2 A-36 IG B1 B2A-36 (1) CAT 5 IG ORDER TAKEUP POWER & COMMUNICATIONS DRIVE THROUGH MONITOR POWER & COMMUNICATIONS E1 E3 E2 SUNDAE / DESSERT MONITORS HEADSET COMMUNICATION WIRING OUT TO SPEAKER POST A-40 E4 A-36 A-38 IG P2 A-27 IG (2) CAT 5 TO MAIN P.O.S. PANEL P1 E5 (2) CAT 5 TO MAIN P.O.S. PANEL DRIVE-THRU MONITOR Q1 Q2 HEADSET BASE STATION POWER AND DATA E2 A-36 R1 R2 TV/CABLE POWER AND COMMUNICATIONS FRY STATION MONITOR POWER AND COMMUNICATIONS S1 S2 DIGITAL FEATURE BOARD POWER AND COMMUNICATIONS POWER AND COMMUNICATIONS FOR FUTURE MONITOR PRINTERS P2 (4) CAT 5 (2) CAT 5 TO SPEAKER POST (1) CAT 6 TO SPEAKER POST (1) CAT 5 TO PHONE TERMINAL BLOCK MAIN P.O.S. PANEL LOCATION (VERIFY w/ OWNER & RDS) (2) CAT 5 (2) CAT 5 (1) CAT 5 TO ABOVE CEILING (4) CAT 5 TO MAIN P.O.S. PANEL (1 EA) CAT 5 (2) CAT 5 TO MAIN P.O.S. PANEL (1) CAT 5 TO MAIN P.O.S. PANEL (1) CAT 5 TO MAIN P.O.S. PANEL W (1) CAT 5 TO MAIN P.O.S. PANEL 110" (5) CAT 5 TO MAIN P.O.S. PANEL A-27 A-36 A-27 A-38A-27 D2 D1 CASH TAKER POWER & COMMUNICATIONS (5) CAT 5 TO MAIN P.O.S. PANEL A-40 DRIVE-THRU MONITOR POWER AND COMMUNICATIONS TO GO ABOVE WINDOW AT 96" AFF212B3 B4 207206204208201 209205201MIR205MIR209200 203202(2) CAT 5 TO MAIN P.O.S. PANEL CONTACT RETAIL DATA SYSTEMS AT 262-896-2600 PRIOR TO ROUGH-IN OF THE P.O.S. SYSTEM TO VERIFY ALL ROUGH-INS. RETAIL DATA SYSTEMS DOES NOT PULL ANY LOW VOLTAGE COMMUNICATIONS CABLE. THE ELECTRICAL CONTRACTOR (EC) IS RESPONSIBLE FOR PULLING OF ALL P.O.S. LOW VOLTAGE CABLE. EC SHOULD INCLUDE IN THE BID PROCESS. WIRING NOTES: 1. POS, PHONE, AND DAILY FEATURE BOARD CABLING TO BE CAT5E. 2. THE SECURITY VIDEO CABLING TO BE RG59. 3. EXTERIOR COMMUNICATIONS AND DRIVE-THRU DETECTOR CABLE TO BE SUITABLE FOR WET LOCATIONS. 4. THE DRIVE-THRU ORDER CONFIRMATION BOARD CABLING TO BE CAT6 FOR TECHKNOW BOARD AND CAT5E FOR HYPERACTIVE BOARD. 5. THE DINING ROOM TV CABLING TO BE RG6 FROM OFFICE TO EACH TV 6. UPON ROUGH-IN COMPLETION AND PRIOR TO DRYWALL, CALL RDS TO ARRANGE A SITE VISIT AND CABLE DELIVERY. 7. ALLOW A MINIMUM OF 72 HOURS FOR WIRE DELIVERY. 8. IF PLENUM CABLE IS NEEDED ALLOW FOR EXTRA LEAD TIME FOR WIRE DELIVERY. 9. VERIFY WITH OWNER AND RDS THE INSTALLATION OF ADDED SYSTEMS TECHKNOW ORDER CONFIRMATION BOARD AND REMOTE EYES CCTV SECURITY SYSTEM. ITEM NOTES 1 FOUR 120V - 1PH - 20 AMP CIRCUITS ARE REQUIRED FOR THE P.O.S. SYSTEM. (1) FOR THE OFFICE & (3) FOR THE OTHER LOCATIONS EACH CIRCUIT IS TO BE DEDICATED WITH ISOLATED GROUNDS. 2 3/4" AND 1" CONDUITS ARE LISTED. 1" IS ACCEPTABLE TO USE IN PLACE OF THE 3/4" LISTED. HOWEVER THE 2" CONDUIT LISTED MUST REMAIN AT 2". 3 RDS/ POS SUPPLIER TO PROVIDE ALL CABLES TO EC. 4 EC TO PULL ALL CABLES AS REQUIRED BY THE P.O.S SYSTEM & WIRELESS ORDERING SYSTEM SUPPLIERS. THESE WIRES ARE TO BE KEPT SEPARATE FROM ALL OTHER LOW VOLTAGE CABLES. 5 RDS TO FURNISH AND INSTALL ALL COVER PLATES AS REQUIRED BY THE P.O.S DRAWINGS. 6 COORDINATE OUTDOOR MENU BOARD COMMUNICATION REQUIREMENTS WITH WIRELESS ORDER SYSTEM SUPPLIER. 7 SEE DRAWINGS E102 AND E103 FOR OTHER POWER, PHONE, AND COMMUNICATION REQUIREMENTS. 8 ALL DIMENSIONS ARE TO THE CENTER OF THE OUTLET BOX. 9 VERIFY AND COORDINATE ALL LOCATIONS AND HEIGHTS WITH SYSTEM SUPPLIERS 10 REFER TO CULVER'S P.O.S. SYSTEM BOX PLACEMENT AND CABLE INSTALLATION GUIDE PREPARED BY RETAIL DATA SYSTEMS OF WISCONSIN FOR ADDITIONAL INFORMATION. 11 SEE DRAWING E105 FOR ELEVATIONS OF P.O.S. ROUGH INS. 12 ALL PIPES SHOULD STUB UP BACK TO MAIN P.O.S. PANEL. ITEM P.O.S SYSTEM ROUGH-IN SCHEDULE A1 DUPLEX OUTLET w/ ISOLATED GROUND @ 20" A.F.F. MOUNT NO LESS THAN 3" AND NO MORE THAN 18" OFF INSIDE CORNER OF DRIVE-THRU WINDOW A2 4" SQUARE BOX w/ SINGLE GANG MUD RING MOUNT VERTICALLY @ 20" A.F.F. AND NO LESS THAN 3" AND NO MORE THAN 18" OFF INSIDE CORNER. PROVIDE (1) 3/4" CONDUIT STUB-UP TO MIN. 12" A.F.C. B1 SINGLE GANG MUD RING. MOUNT VERTICALLY (NO BOX NEEDED) @ 85" A.F.F. AND WITHIN 5' OF INSIDE CORNER OF DRIVE-THRU WINDOW. PROVIDE (1) 2" CONDUIT STUB-UP TO MIN. 12" A.F.C. B2 DOUBLE DUPLEX OUTLET w/ ISOLATED GROUND @ 85" A.F.F. MOUNT WITHIN 5' OF INSIDE CORNER OF DRIVE-THRU WINDOW. B3 4" SQUARE BOX w/ SINGLE GANG MUD RING. MOUNT VERTICALLY @ 85" A.F.F. PROVIDE (1) 3/4" CONDUIT STUB-UP TO MIN.12" A.F.C. B4 DOUBLE DUPLEX OUTLET w/ ISOLATED GROUND @ 85" A.F.F. C1 (1) 1" CONDUIT STUB UP 10" A.F.F. CONNECT TO BOX C2 C2 (1) 1" CONDUIT STUB UP TO MIN. 12" A.F.C. CONNECT TO BOX C1 C3 (3) LOCATIONS - DUPLEX OUTLET MOUNTED IN A 4" SQUARE BOX. TO BE LOCATED ON THE LOWEST SHELF NEAR THE REAR RIGHT OF THE OPENING. D1 4" SQUARE BOX w/ SINGLE GANG MUD RING MOUNT VERTICALLY @ 20" A.F.F. AND NO LESS THAN 3" & NO MORE THAN 18" OFF INSIDE CORNER. PROVIDE (1) 3/4" CONDUIT STUB-UP MIN. 12" A.F.C. D2 DUPLEX OUTLET w/ ISOLATED GROUND @ 20" A.F.F. MOUNT NO LESS THAN 3" AND NO MORE THAN 18" OFF INSIDE CORNER OF DRIVE THRU WINDOW. E1 SINGLE GANG MUD RING. MOUNT VERTICALLY (NO BOX NEEDED) @ 85" A.F.F. PROVIDE (1) 2" CONDUIT STUB-UP TO MIN. 12" A.F.C. E2 (2) DOUBLE DUPLEX OUTLET w/ ISOLATED GROUND @ 85" A.F.F. E3 4" SQUARE BOX w/ SINGLE GANG MUD RING. MOUNT VERTICALLY@ 54" A.F.F. PROVIDE (1) 3/4" CONDUIT STUB-UP TO MIN. 12" A.F.C. E4 DUPLEX OUTLET w/ ISOLATED GROUND @ 54" A.F.F. MOUNT NEXT TO LOCATION E3 E5 SINGLE GANG MUD RING. MOUNT VERTICALLY (NO BOX NEEDED) @ 85" A.F.F. PROVIDE (1) 2" CONDUIT STUB-UP TO MIN. 12" A.F.C. F1 4" SQUARE BOX w/ SINGLE GANG MUD RING. MOUNT VERTICALLY @ 70" A.F.F. PROVIDE (1) 3/4" CONDUIT RUN TO LOCATION F2 ITEM P.O.S SYSTEM ROUGH-IN SCHEDULE F2 SINGLE GANG MUD RING. MOUNT VERTICALLY (NO BOX NEEDED) @ 85" A.F.F. DIRECTLY ABOVE JBOX F1. PROVIDE (1) 2" CONDUIT STUB-UP TO MIN. 12" A.F.C., TOWARDS FRYER HOOD. F3 DOUBLE DUPLEX OUTLET w/ ISOLATED GROUND @ 85" A.F.F. MOUNT NEXT TO LOCATION F2 G1 SINGLE GANG MUD RING. MOUNT VERTICALLY (NO BOX NEEDED) @ 66" A.F.F. AND WITHIN 16" OF SIDE OF PASS-THRU. PROVIDE (1) 2" CONDUIT STUB-UP TO MIN. 12" A.F.C. INTO KITCHEN AREA. G2 DOUBLE DUPLEX OUTLET w/ ISOLATED GROUND @ 66" A.F.F. MOUNT A MINIMUM OF 3", AND NOT TO EXCEED 16", FROM SIDE OF PASS-THRU H1 SINGLE GANG MUD RING MOUNT VERTICALLY (NO BOX NEEDED) @ 6" ABOVE ROUGH OPENING OF PASS-THRU. PROVIDE (1) 2" CONDUIT STUB-UP TO MIN 12" A.F.C., TOWARD KITCHEN AREA H2 DUPLEX OUTLET w/ ISOLATED GROUND. MOUNT 6" ABOVE ROUGH OPENING OF PASS-THRU I1 SINGLE GANG MUD RING MOUNT VERTICALLY (NO BOX NEEDED) @ 6" ABOVE ROUGH OPENING OF PASS-THRU. PROVIDE (1) 2" CONDUIT STUB-UP TO MIN. 12" A.F.C., TOWARD KITCHEN AREA I2 DUPLEX OUTLET w/ ISOLATED GROUND. MOUNT 6" ABOVE ROUGH OPENING OF PASS-THRU; LOCATE NEXT TO I1 J1 4" SQUARE BOX w/ SINGLE GANG MUD RING. MOUNT VERTICALLY @ 20" A.F.F. PROVIDE (1) 3/4" CONDUIT STUB-UP TO MIN. 12" A.F.C. J2 DUPLEX OUTLET w/ ISOLATED GROUND @ 26" A.F.F. MOUNT DIRECTLY ABOVE LOCATION J1 K1 DOUBLE DUPLEX OUTLET w/ ISOLATED GROUND; MOUNT IN FINISHED CEILING. K2 NO ACTUAL ROUGH IN NEEDED IN CEILING. REFERENCE ONLY FOR LOCATION. LEAVE 10' SERVICE LOOP ON COMMUNICATION CABLES TO ALLOW FOR DROP THROUGH MONITOR MOUNTING BRACKETS TO END TERMINATION POINT. L1 SINGLE GANG MUD RING MOUNT HORIZONTALLY (NO BOX NEEDED) @ 8" BELOW FINISHED CEILING, NOT TO EXCEED 108" A.F.F. PROVIDE (1) 2" CONDUIT STUB-UP TO MIN. 12" A.F.C. L2 4" SQUARE BOX w/ SINGLE GANG MUD RING. MOUNT VERTICALLY @ 18" A.F.F. PROVIDE (1) 3/4" CONDUIT STUB-UP TO MIN. 12" A.F.C. L3 DOUBLE DUPLEX OUTLET w/ ISOLATED GROUND @ 8" BELOW FINISHED CEILING AND NOT TO EXCEED 108" A.F.F. LOCATE A MINIMUM OF 12" TO THE RIGHT OF LOCATION L1 ITEM P.O.S SYSTEM ROUGH-IN SCHEDULE L4 SINGLE GANG MUD RING MOUNT VERTICALLY (NO BOX NEEDED) @ 8" BELOW FINISHED CEILING AND NOT TO EXCEED 108" A.F.F. LOCATE MINIMUM 12" TO THE LEFT OF L1 M1 4" SQUARE BOX w/ SINGLE GANG MUD RING: MOUNT VERTICALLY @ 85" A.F.F. PROVIDE (1) 3/4" CONDUIT STUB-UP TO MIN. 12" A.F.C. PROVIDE (1) 3/4" CONDUIT TO M3 LOCATION M2 DUPLEX OUTLET w/ ISOLATED GROUND @ 85" A.F.F. M3 4" SQUARE BOX w/ SINGLE GANG MUD RING. MOUNT VERTICALLY @ 70" A.F.F. N1 4" SQUARE BOX w/ SINGLE GANG MUD RING. MOUNT VERTICALLY @ 85" A.F.F. AND WITHIN 16" OF WALL EDGE. PROVIDE (1) 2" CONDUIT STUB-UP TO MIN. 12" A.F.C. TOWARD REAR OF KITCHEN. N2 DOUBLE DUPLEX OUTLET w/ ISOLATED GROUND @ 85" A.F.F. AND WITHIN 16" OF EDGE OF WALL. N3 4" SQUARE BOX w/ SINGLE GANG MUD RING. MOUNT VERTICALLY @ 54" A.F.F. PROVIDE (1) 3/4" CONDUIT STUB-UP TO MIN. 12" A.F.C. TOWARD REAR OF KITCHEN. P1 SINGLE GANG MUD RING. MOUNT VERTICALLY (NO BOX NEEDED) @ 66" A.F.F. AND WITHIN 16" OF SIDE OF PASS-THRU. PROVIDE (1) 2" CONDUIT STUB-UP TO MIN. 12" A.F.C. INTO KITCHEN AREA P2 DOUBLE DUPLEX OUTLET w/ ISOLATED GROUND @ 66" A.F.F. MOUNT MIN. 3" AND NOT TO EXCEED 16" FROM SIDE OF THE PASS-THRU Q1 DOUBLE DUPLEX OUTLET W/ ISOLATED GROUND @ 68" A.F.F. MOUNT 78" FROM WALL Q2 4" SQUARE BOX WITH SINGLE GANG MUD RING. MOUNT VERTICALLY @ 78"A.F.F. PROVIDE (1) 3/4" CONDUIT STUB-UP TO MIN. 12" A.F.C. R1 SINGLE GANG MUD RING. MOUNT VERTICALLY (NO BOX NEEDED) @ 84" A.F.F. - VERIFY LOCATION WITH OWNER PROVIDED MOUNTING BRACKET. R2 DOUBLE DUPLEX OUTLET WITH ISOLATED GROUND @ 84" TO 78" A.F.F. - VERIFY LOCATION WITH OWNER PROVIDED MOUNTING BRACKET. S1 DUPLEX OUTLET WITH ISOLATED GROUND @ 110" A.F.F. - VERIFY LOCATION WITH OWNER PROVIDED MOUNTING BRACKET S2 SINGLE GANG MUD RING MOUNTED VERTICALLY (NO BOX NEEDED )@ 110" A.F.F. - VERIFY LOCATION WITH OWNER PROVIDED MOUNTING BRACKET. B TELEVISION OUTLET JUNCTION BOX - DIRECT CONNECTION DUPLEX RECEPTACLE w/GROUND FAULT & WEATHERPROOF COVER DUPLEX RECEPTACLE w/GROUND FAULT - HUBBELL GFR5362SGW DUPLEX RECEPTACLE DUPLEX RECEPTACLE - CEILING SWITCH TELEPHONE LEGEND GFI 220 VOLT DEDICATED DUPLEX OUTLET w/ ISOLATED GROUND CHIME DOOR CHIME - EDWARDS C212-2L WITH CONTROL POWER TRANSFORMER DUPLEX RECEPTACLE w/ ISOLATED GROUND FOR ELECTRONIC EQUIPMENT QUAD RECEPTACLE HDMI CONNECTION ETHERNET CONNECTION CAT 5E OR 6 USB DUPLEX RECEPTACLE - WALL HUBBELL # USB15A5W WIRELESS ROUTER DOOR CHIME ENTRANCE PUSHBUTTONDB DEEP BOX WITH GANG PLASTER RING, 20 AMP DEADFRONT GFI & NEMA 5 20 AMP DUPLEX RECEPTACLE. LOCATE DEADFRONT GFI IN ELECTRICAL ROOM. PROVIDE WITH LABEL INDICATING DEVICE PROTECTED. DEDICATED QUAD OUTLET WITH ISOLATED GROUND COMMUNICATION JUNCTION BOX B29 PANEL DESIGNATION BREAKER DESIGNATION SDD DUCT SMOKE DETECTOR w/ REMOTE ALARM / TEST STATION. MOUNT ALARM / TEST NEAR FIRE ALARM PANEL OR AS DESIGNATED BY OWNER'S REPRESENTATIVE. PROVIDED BY LENOX BUMP BAR MONITOR CABLE GFI SINGLE RECEPTACLE w/GROUND FAULT - LEVITON X7891 E TV SWP GFI IG USB GFI W JB H C ID TAG SEE EQUIP. SCHED. ON E201 A-20 PANEL DESIGNATION BREAKER DESIGNATION Reference POS Plans for box layout C1 (R1-R3) J1 A2 (R5) (1) CAT5 TO POS PANEL G1 D1 (R4) (4) CAT5 TO POS PANEL (Set) P1 (Set2) (4) CAT5 TO POS PANEL (1) CAT5 TO POS PANEL (4) CAT5 TO POS PANEL WAP (Dining) (9) CAT5 TO POS PANEL (1) CAT5 TO POS PANEL DDF (2) CAT5 TO POS PANEL H1 E1 (Dessert)(1) CAT5 TO POS PANEL (2) CAT5 E3 (2) CAT5 (2) CAT5 E5 (Dessert) (2) CAT5 TO POS PANEL MAIN POS PANEL IN OFFICE L1 (1) CAT5 TO MAIN POS PANEL B1 (Park2) B3 (Park2A) (2) CAT5 TO POS PANEL F1 (2) CAT5 F2 (Fry) M3 (1) CAT5 TO POS PANEL M1 (Grill) Above Ceiling Near I1 (2) CAT5 TO POS PANEL O1 (R6) I1 (2) CAT5 TO POS PANEL N1 (Custard) (2) CAT5 TO POS PANEL K2 (Bun) N3 (2) CAT5 TO POS PANEL (2) CAT5 TO MAIN POS PANELL2 Dining TV(s) HEADSET WIRING (Supplied by Headset Vendor)R1 (1) CAT6 TO POS PANEL (Supplied by Acrelec) Speaker Post #1 Speaker Post #2(2) CAT5(1) CAT5(1) CAT5 TO POS PANEL (per TV)50' VGA CABLE (optional)25'VGA CABLE(1) CAT5(1) CAT5(1) CAT5POS WIRING LAYOUT W/ MIRROR IMAGE(S) MAIN ENTRY DRIVE-THRU REAR RIGHT SIDE LEFT SIDE FRONT SEE SITE PLAN FOR NORTH ORIENTATION # MONITOR SCHEDULE 200 GRILL STATION 201 FRY STATION 202 BUN STATION - DINE-IN 203 BUN STATION - DRIVE-THRU 204 DESSERT STATION 205 SET STATION 206 DESSERT STATION 207 DRIVE-THRU STATION - DRINKS & DESSERTS 208 CUSTARD STATION 209 SET STATION - ONLINE/TO-GO 212 DRIVE-THRU STATION - FULL ORDER 201 MIR. FRY STATION 205 MIR. SET STATION E104P.O.S. SYSTEMS PLAN NEW CULVER'S RESTAURANT431 E Carmel DriveCarmel, IN 46032County of HamiltonDate:Revision:5-25-2022OLLMANN ASSOCIATES ARCHITECTS, P.C.200 South State StreetBelvidere, Illinois 61008815-544-7790 Phone© 2022K&J INVESTMENTS XVI, LLC1448 Conner StreetNoblesville, IN 46060Bob Goins: bgoins@indyculvers.com317-770-4656OWNER:Culver Franchising System, Inc.1240 Water StreetPrairie du Sac, WI 53578608-643-7980®2020-159 © OAA All rights reserved; any copying, transmittal or disclosure subject to OAA written approval. E4 SCALE : 1/4" = 1'-0"POS SYSTEMS PLAN01/13/23